Loading...
HomeMy WebLinkAboutM1-02A-MECHANICAL-FLOOR-PLAN-LEVEL-2---AREA-A-Rev.1DN 5 5 8 11 11 12 12 17 21 21 L L P T 1 1 Y Y U U 18 18 N N 7 W W RR 2015 15146 X 2 2 3 M M ZZ 19 19 9.2 9.2 L.5 0.9 6.7 VRF-2-01 SD8 155 6" 6" LS10-3 235 LS10-3 235 VRF-2-148" VRF-2-1516"x12"EDH-2-15 24"x14"24"x14"12"10"10" 18"x10"18"x10"18"x10"18"x10"18"x10"10"x12"10"10"10"10"10"10"10"x12"10"x12"10"x12"22"x10"EDH-2-12 VRF-2-12 14"x12"14"x12"10"10" 10" 10" 10" SD6 50 SD6 25 LS10-3 235 LS10-3 240 LS10-3 240 LS10-3 230 LS10-3 230LS10-3 230LS10-3 230 LS10-3 230 LS10-3 230 LS10-4 400 LS10-4 410 LS10-3 230 LS10-4 410 LS8-2 200 LR8 LR8 LR6 LR6 8" LR8LR8LR8 COVERED PORCH 205 CART STOR. 216 CORRIDOR 203 ELEVATOR LOBBY 208 BELL ACCESS 233 MEN 239 PREFUNCTION 242 STORAGE 206 MEETING 201 BREAKOUT 243 STORAGE 241 COATS 240 EG1 355 EG1 305 12"5 M5-01 8" 12" 10" 5 M5-01 10" 10" 24"x14"R22"x10" 5 M5-01 EBH-1 EBH-2 EBH-3 32"x16" RG3 24"x12"8 M5-01 2 M5-01 2 2 2 2 2 2 2 2 5 LR8 1 3 5 14"x12"16"x16"12"x10"10"12"x10" 32"x16" 2 32"x16" 4 10"2 M5-01 FD GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M1-02A 03/22/19 MECHANICAL FLOOR PLAN LEVEL 2 - AREA A 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/4" = 1'-0"M1-02A 1 MECHANICAL FLOOR PLAN LEVEL 2 - AREA A # PLAN NOTES: 1 ABOVE CEILING TRANSFER DUCT TO GRILLE IN RESTROOM CEILING. REFER TO DETAIL 8/M5-01. 2 SEAL DUCT PENETRATION THROUGH SOUND RATED PARTITION PER DETAIL 15/M5-01. 3 OPEN END OF FAN COIL UNIT RETURN DUCT TO BE COVERED WITH A 2", MERV 8 FILTER. FILTER TO BE FASTENED TO DUCT IN A MANNER THAT FACILITATES REMOVAL AND REPLACEMENT OF FILTER. TYPICAL OF ALL FIRST AND SECOND FLOOR FAN COIL UNITS. 4 PROVIDE VOLUME DAMPER AT OUTDOOR AIR CONNECTION TO FAN COIL UNIT RETURN AIR PLENUM, TYPICAL. 5 BALANCE DAMPER NOT REQUIRED IN SUPPLY BRANCH DUCT TO SLOT DIFFUSER. AIRFLOW TO BE BALANCED BY A MANUFACTURER SUPPLIED, CABLE OPERATED DAMPER KIT. TYPICAL OF ALL SLOT DIFFUSERS. REFER TO GRILLE, REGISTER AND DIFFUSER SCHEDULE. NO. DATE DESCRIPTION