M1-02B-MECHANICAL-FLOOR-PLAN-LEVEL-2---AREA-B-Rev.1
5 11 11 12 21 21 23 23 D D F F J L L 1 1 A A 94 18 18 7 7 20 20 1615 15 13 E G G 2 2 3 3 10 22 22 24 B B M 19 19 C H 9.2 L.5 A.7 DS-4 SD6 50 SD6 105 A/V ROOM 244 6" MECHANICAL 248 1 M4-03 VRF-2-14 VRF-2-16 VRF-2-17 VRF-2-19 VRF-2-18 EDH-2-18 VRF-2-13 EDH-2-17 SD8 280 SD8 280 8" SD8 155 10"VRF-2-15 8" 22"x12"22"x12" 10"LS10-3 230 16"x12"16"x12"LS10-4 410 10"10"LS10-4 410 LS10-3 230 LS10-3 230 LS10-3 230 10"10"22"x10"22"x10"22"x10"22"x10"14"x12"14"x12"14"x12"10"12"x12"20"x10"20"x10"LS8-2 200LS8-2 200 LS8-2 200 LS8-2 200 LS10-3 360LS10-3 360LS10-3 360 LS8-2 200LS8-2 200 LS10-3 340 LS10-3 345 LS8-2 200 LS8-2 200 LR8 LS10-3 345 LS10-3 345 10" 10" 10" 10"10"10"18"x12"12"x12"12"x12"10"10"10"10"10"8"8" 8"8" 8"8" 8"8" 10"10"8" 8" SD8 15514"x12"JAN 245 HOLDING KITCHEN 237 SERVICE 236 STAIR #1 2ST1 CORRIDOR 235 BALLROOM 246 PREFUNCTION 242 WOMEN 238 24"x14" EG1 75 EG1 75 EG1 305 12"6" 4" 12" 5 M5-01 5 M5-01 5 M5-01 5 M5-01 5 M5-01 5 M5-01 1 30"x14"26"x12"20"x10"4" 4" 12" 3 M3-01 12" 12" 12" 22"x12" 12" 10" R D R D36"x16" 36"x12" RG3 24"x12" 6" 30"x14" 2 M5-01 2 M5-01 2 M5-01 2 2 2 2 2 2 2 2 22 10"10"22"x12"22"x12" 14" 14"14" 12" 8 M5-01 32"x16"2 M5-01 24"x16"2 M5-01 LR8 12"26"x12"LR8 LR8LR8 36"x12"18"x14"12"18"x14"18"x14"18"x14" 6 3 3 3 3 3 3 4 4 4 4 4 5 5 5 FD FD SG2 200 10"x6" GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M1-02B 03/22/19 MECHANICAL FLOOR PLAN LEVEL 2 - AREA B 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/4" = 1'-0"M1-02B 1 MECHANICAL FLOOR PLAN LEVEL 2 - AREA B # PLAN NOTES: 1 MOUNT AT 8'-0" A.F.F. 2 SEAL DUCT PENETRATION THROUGH SOUND RATED PARTITION PER DETAIL 15/M5-01. 3 OPEN END OF FAN COIL UNIT RETURN DUCT TO BE COVERED WITH A 2" MERV 8 FILTER. FILTER TO BE FASTENED TO DUCT IN A MANNER THAT FACILITATES REMOVAL AND REPLACEMENT OF FILTER. TYPICAL OF ALL FIRST AND SECOND FLOOR FAN COIL UNITS. 4 PROVIDE VOLUME DAMPER AT OUTDOOR AIR CONNECTION TO FAN COIL UNIT RETURN AIR PLENUM, TYPICAL. 5 BALANCE DAMPER NOT REQUIRED IN SUPPLY BRANCH DUCT TO SLOT DIFFUSER. AIRFLOW TO BE BALANCED BY A MANUFACTURER SUPPLIED, CABLE OPERATED DAMPER KIT. TYPICAL OF ALL SLOT DIFFUSERS. REFER TO GRILLE, REGISTER AND DIFFUSER SCHEDULE. 6 BALANCE EXHAUST DUCT TO 845 CFM TO BE PULLED FROM CEILING PLENUM. COVER DUCT OPENING WITH HEAVY DUTY WIRE MESH. NO. DATE DESCRIPTION