Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M1-02C-MECHANICAL-FLOOR-PLAN-LEVEL-2---AREA-C-Rev.2
DN 21 23 26 28 30 32 L L Y Y U U K N N W W 31 RR 292725 X S V Q M ZZ ERH-2 ERH-3ERH-1 VRF-2-06 VRF-2-05 VRF-2-09 VRF-2-04 VRF-2-10 VRF-2-03 VRF-2-07 VRF-2-02 VRF-2-08 EDH-2-03 VRF-2-11 DS-4 SD6 50 SD6 105 SD6 105 RG3 SD6 105 10" 10" 8" 6" 12"12"12"10"RG3 SD6 100 6"10"8" RG3 SD8 215 LS6-21 65 LS8-2 230 LS8-2 230 LS8-2 230 LS6-10 280 LS10-3 280 LR3 LR3 LS10-3 280 LS10-3 280 10"12"10"10" 10"10"MECHANICAL 248 CORRIDOR 247 UNISEX 225 WOMEN 223 JAN 224 MEN 222 CORR 220 CORRIDOR 203 FURNITURE STORAGE 217 STAIR #2 2ST2 F&B 219 CATERING 218 LIBRARY 210 BOARDROOM 211 GM 212 VEST 213 REVENUE 214 VEST 221 LOBBY 202 LOBBY BAR 207 VESTIBULE 204 CART STOR 209 CART STOR. 216 CORRIDOR 234 LUGGAGE 232 F.O. MANAGER 231 VEST 228 WORK 227 RETAIL 226 SERV 229 WELCOME DESK 230 1 M4-03 28"x16"28"x16" 24"x24" 24"x24" 6"22"x10"22"x10"22"x10"18"x10"18"x10"10"8"8"8" 8" 8" 8" 8" 8" 8" 10"x8"10"x8"10"x8"10"x8"SD8 155 LS6-1 115 6" 8" 8" SD8 170 10"10"EG3 125 8" 10" 8" 8" 10" EG1 335 6" EG1 75 10" 28"x16"28"x16"28"x16" RG3 SD6 105 SD6 105 6" 6" 4" 4" 6" 8" 24"x22"24"x22" 24"x14" SD8 15010"x10"6" 6" 10" 6" 6"RG3 SD6 65 6" 10"10"8" 6" EG1 160 EG1 160 RG3 SD6 120 6" 6" 6" 6" 8" 10" 6"6" LS10-3 235 LS10-3 235 LS10-3 235 LS10-3 235 LS8-2 230LS8-2 230LS8-2 230 LR8LR8 6" LR8 RD RRRRDRD5 M5-01 5 M5-01 5 M5-01 5 M5-01 SD6 50 LS6-1 115 6" SG2 5014"x12"D24"x14"24"x14" 1 1 10"2 14"x12"16"x10"16"x10" 6" 24"x22"24"x20"24"x20" 4" 4"4" 6"30"x14"8" 30"x14"DR D EDH-2-04 6"6" 10" 14"x14" 10"x6" RG3 RG3 24"x12"24"x12" LS10-3 315 2 M5-01 8 M5-01 8 M5-01 2 M5-01 3 3 3 3 FD FD 4 4 33 3 3 3 33 3 3333 3 5 6 14"x12"16"x16"18"x14"18"x14" 7 7 10"10"12"10"10"12"10"10"10" 10"10"10" 2 M5-01 40"x16" 5 6 RG4 RG3RG3 RG4 14"x12" 2 M5-01 FD FD 8" 8 9 2 M4-03 SG2 200 10"x6" GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M1-02C 03/22/19 MECHANICAL FLOOR PLAN LEVEL 2 - AREA C 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/4" = 1'-0"M1-02C 1 MECHANICAL FLOOR PLAN LEVEL 2 - AREA C # PLAN NOTES: 1 BALANCE EXHAUST DUCT TO 845 CFM TO BE PULLED FROM CEILING PLENUM. COVER DUCT OPENING WITH HEAVY DUTY WIRE MESH. 2 MOUNT AT 8'-0" A.F.F. 3 SEAL DUCT PENETRATION THROUGH SOUND RATED PARTITION PER DETAIL 15/M5-01. 4 PROVIDE FIRE DAMPER AND ACCESS PANEL AT SHAFT PENETRATION. 5 OPEN END OF FAN COIL UNIT RETURN DUCT TO BE COVERED WITH A 2" MERV 8 FILTER. FILTER TO BE FASTENED TO DUCT IN A MANNER THAT FACILITATES REMOVAL AND REPLACEMENT OF FILTER. TYPICAL OF ALL FIRST AND SECOND FLOOR FAN COIL UNITS. 6 PROVIDE VOLUME DAMPER AT OUTDOOR AIR CONNECTION TO FAN COIL UNIT RETURN AIR PLENUM, TYPICAL. 7 BALANCE DAMPER NOT REQUIRED IN SUPPLY BRANCH DUCT TO SLOT DIFFUSER. AIRFLOW TO BE BALANCED BY A MANUFACTURER SUPPLIED, CABLE OPERATED DAMPER KIT. TYPICAL OF ALL SLOT DIFFUSERS. REFER TO GRILLE, REGISTER AND DIFFUSER SCHEDULE. 8 10" I.D. DOUBLE WALL CHIMNEY FLUE. ROUTE UP THROUGH GUESTROOMS IN 2-HR RATED SHAFT WALL UP TO A MINIMUM OF 2'-0" ABOVE ALL ADJACENT MANSARD ROOF. TERMINATE IN VENT CAP. 9 SHEET METAL DUCT SIZED AS INDICATED FOR FIREPLACE COMBUSTION AIR. ROUTE FROM FIREPLACE CONNECTION TO ABOVE CEILING AND OUT TO MANUFACTURER PROVIDED INTAKE DAMPER IN SOFFITT. NO. DATE DESCRIPTION 5 08/13/2019 FIREPLACE DUCTWORK REVISION 6 10/23/19 MISC. CHANGES