Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M1-03-MECHANICAL-FLOOR-PLAN-LEVEL-3-Rev.1
GUESTROOM LUXURY SUITE A 321 GUESTROOM KING 320 GUESTROOM KING 319 GUESTROOM KING 318 GUESTROOM KING 316 GUESTROOM QQ 314 ADA GUESTROOM LUXURY SUITE B 312 GUESTROOM KING STUDIO 311 GUESTROOM KING STUDIO 310 STAIR #1 3ST1 MECH 304 CORRIDOR 303 GUESTROOM KING 313 FITNESS 310 ELEVATOR LOBBY 308 ELEC 306 HOUSEKEEPING 307 CORRIDOR 302 CORRIDOR 301 GUESTROOM KING 327 GUESTROOM KING 329 GUESTROOM KING 331 GUESTROOM KING 333 GUESTROOM KING 335 GUESTROOM KING 337 GUESTROOM JUNIOR SUITE W/ ADA COMM. 339 STAIR #2 3ST2 GUESTROOM QQ 340 GUESTROOM QQ W/BALCONY 338 GUESTROOM KING 336 GUESTROOM KING 334 ADA GUESTROOM KING W/ ADA COMM. 332 GUESTROOM KING 330 GUESTROOM KING 328 GUESTROOM KING 326 GUESTROOM KING 325 GUESTROOM KING 324 GUESTROOM KING 323 GUESTROOM QQ W/ ADA COMM. 322 2 M4-01 3 M4-01 1 M4-01 1 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 FCU-A 2 M4-01 1 M4-02 2 M4-02 2 M4-01 2 M4-01 4 M4-01 6 M4-01 5 M4-01 RG2 RG2 26"x11" FCU-B SG1 450 FCU-B FCU-B FCU-B FCU-BFCU-BFCU-BFCU-BFCU-BFCU-BFCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B DS-5 KEF-1 KEF-2 KEF-3 CU-1 DSCU-4 DSCU-1 DSCU-2 DSCU-3 EWH-10 EWH-9 EF-2 26"x11" 20"x8" 20"x8" SG1 450FCU-B FCU-B 5 8 11 11 12 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J L L P T 1 1 Y Y U U A A 94 18 18 K N N 7 W W 31 31 R R 201615 15 29 29 27 2725 25 146 13 E G G X S V 2 2 3 10 22 24 B B Q M Z Z 19 19 C H 9.2 L.5 A.7 6.7 FD FCU-BFCU-BFCU-B FCU-BFCU-BFCU-B FD FDFDFDFDFD FD FD FDFD FCU-B FDFD FCU-BFCU-B FDFDFD FCU-BFCU-B FD SG2 250 EG1 200 EG1 200 8" 8"8" 8" FDFD FD SG2 250 FD FD FD FSD FD FDFD FDFD FDFD FD FD FD FD FD FDFDFD 10" 10"x6"SG2 225 SG2 225 RG6 450 FD SD8 155 SG2 155 10"x6"12"x6" 6" 14"x6"14"x6" FDFDFDFDFDFD FD FDFD FDFD FDFD FD FDFDFSD FDFDFDFDFDFD RG5 FD FD FD FD 10"x6" FD FD FD 10"x6" 10"x6" 114"x6"2 EG3 40 6"x8"6"x8" R1 M6-02 R2 M6-02 R2 M6-02 R2 M6-02 R2 M6-02 R2 M6-02 R2 M6-02 R7 M6-02 R5 M6-02 R1 M6-02 R2 M6-02 R8 M6-02 R6 M6-02 R6 M6-02 R1 M6-02 R1 M6-02 R3 M6-02 R4 M6-02 R1 M6-02 R2 M6-02 7 M5-01 6 M5-01 10 M5-01 10 M5-01 33 3 3 666 3 6 6 4 5 5 6 73 3 6 12 M5-01 12 M5-01 12 M5-01 8" 7 M5-01 MUA-2MUA-1 14"x6" GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M1-03 03/22/19 MECHANICAL FLOOR PLAN LEVEL 3 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/8" = 1'-0"M1-03 1 MECHANICAL FLOOR PLAN LEVEL 3 # PLAN NOTES: 1 SUPPLY AND EXHAUST AIR DUCT RISERS SERVING FIRST AND SECOND FLOOR FROM ERV'S LOCATED ON ROOF. 2 MOUNT AT 8'-0" A.F.F. 3 BALANCE OUTDOOR AIR TO GUESTROOM FAN COIL UNIT TO 50 CFM, TYPICAL. 4 BALANCE OUTDOOR AIR DUCT TO 105 CFM. 5 BALANCE OUTDOOR AIR DUCT TO 200 CFM. 6 BALANCE GUESTROOM EXHAUST AIR GRILLE TO 50 CFM, TYPICAL. 7 PROPOSED LOCATION FOR KITCHEN EQUIPMENT CONDENSING UNITS. REFER TO KEC PLANS. NO. DATE DESCRIPTION 1 04/09/2019 LOW ROOF REV. 6 10/23/19 MISC. CHANGES