Loading...
HomeMy WebLinkAboutM1-06-MECHANICAL-FLOOR-PLAN-LEVEL-6-Rev.1STAIR #2 6ST2 VEST 605 GUESTROOM JUNIOR SUITE 639 GUESTROOM KING 637 GUESTROOM KING 635 GUESTROOM KING 633 GUESTROOM KING 631 GUESTROOM KING 629 GUESTROOM KING 627 HOUSEKEEPING 607 ELEVATOR LOBBY 608 ELEC 606 CORRIDOR 601 CORRIDOR 602 GUESTROOM KING W/ ADA COMM. 617 GUESTROOM KING 615 GUESTROOM KING 613 MECH 604CORRIDOR 603 STAIR #1 6ST1 GUESTROOM KING STUDIO 610 GUESTROOM KING STUDIO 611 ADA COMM. GUESTROOM LUXURY SUITE B 612 GUESTROOM KING 614 GUESTROOM KING 616 GUESTROOM KING 618 GUESTROOM KING 619 GUESTROOM KING 620 ADA GUESTROOM LUXURY SUITE A 621 GUESTROOM QQ 622 GUESTROOM KING 623 GUESTROOM KING 624 GUESTROOM KING 625 GUESTROOM KING 626 GUESTROOM QQ 628 GUESTROOM KING 630 GUESTROOM KING 632 GUESTROOM KING 634 GUESTROOM KING 636 GUESTROOM QQ W/BALCONY 638 GUESTROOM QQ W/ ADA COMM. 640 DS-8 FCU-B FCU-B FCU-B FCU-B FCU-B 2 M4-01 3 M4-01 1 M4-01 1 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-01 2 M4-011 M4-02 2 M4-02 2 M4-01 2 M4-01 4 M4-01 6 M4-01 5 M4-01 2 M4-01 5 M4-01 22"x12"22"x12"22"x12"22"x12" 5 8 11 11 12 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J L L P T 1 1 Y Y U U A A 94 18 18 K N N 7 W W 31 31 R R 201615 15 29 29 27 2725 25 146 13 E G G X S V 2 2 3 10 22 24 B B Q M ZZ 19 19 C H 9.2 L.5 A.7 6.7 R1 M6-02 R2 M6-02 R2 M6-02 R2 M6-02 R2 M6-02 R2 M6-02 R2 M6-02 R7 M6-02 R5 M6-02 R1 M6-02 R2 M6-02 R8 M6-02 R6 M6-02 R9 M6-02 R1 M6-02 R1 M6-02 R3 M6-02 R4 M6-02 R1 M6-02 16"x12"16"x12" R2 M6-02 30"x10" 16"x12" FCU-BFCU-BFCU-BFCU-BFCU-BFCU-BFCU-BFCU-BFCU-BFCU-BFCU-BFCU-B FDFD FDFD FD FD FD FD FD FD FD FD FCU-BFCU-BFCU-BFCU-BFCU-BFCU-B FD FDFDFDFDFDFD FCU-B FCU-B FCU-B FCU-B FCU-B FCU-BFCU-BFD FD FD FCU-B FCU-B FCU-B FD FD FD FD FD FD FD FDFD FDFD 16"x12" 12"x12" 30"x10" 12"x8" 12"x8" 14"x6" RG7 685 10"x6" 6"x10"6"x10" 16"x12"12"x8"8"x12" 8"x12"12"x8"8"x12" 8"x12" 8"x12"12"x8" FD18"x8" 16"x12" SG2 250 10"x6" SD SG2 250 FD SG3 685 18"x10"16"x8"16"x8"22"x10"22"x12"22"x10"22"x12"22"x10"FD FDFD FDFDFD FD FD FD FD FD FDFD FDFD FD FD FD FD FD FD FD FD FD FD FDFD FD FD 12 3 3 3 3 555 3 5 54 5 3 3 5 3 5 14"x6" FCU-C SD8 155 6" EG3 40 SG2 155 10"x6"12"x6"FCU-A RG5 315 8" SD GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M1-06 03/22/19 MECHANICAL FLOOR PLAN LEVEL 6 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/8" = 1'-0"M1-06 1 MECHANICAL FLOOR PLAN LEVEL 6 # PLAN NOTES: 1 SUPPLY AND EXHAUST AIR DUCT RISERS SERVING FIRST AND SECOND FLOOR FROM ERV'S LOCATED ON ROOF. 2 MOUNT AT 8'-0" A.F.F. 3 BALANCE OUTDOOR AIR TO GUESTROOM FAN COIL UNIT TO 50 CFM, TYPICAL. 4 BALANCE OUTDOOR AIR DUCT TO 105 CFM. 5 BALANCE GUESTROOM EXHAUST AIR GRILLE TO 50 CFM, TYPICAL. NO. DATE DESCRIPTION 6 10/23/19 MISC. CHANGES