HomeMy WebLinkAboutM4-01-MECHANICAL-ENLARGED-PLANS-Rev.1T T T T T T GUESTROOM KING 328 SG1 450 24"x6" 23 23 Y Y U U W W 25 25 VV ZZ 12"x6" 12"x6" FD FD 4" 4" FCU-B 26"x11"RG2 BD EG2 50 FCU-B 1 2 3 5 M5-01 12 M5-01 3 M5-01 GUESTROOM QQ 314 RG2 26"x11" FCU-B 24"x6" SG1 450 F F 99 44 77 G G EG2 50 BD FD FD4" 4" 14"x10" 12"x6" FCU-B 2 1 3 5 M5-01 12 M5-01 3 M5-01 GUESTROOM KING STUDIO 311 SG1 450 26"x11" FCU-B 24"x6" 11 11 D D A A 13 13 10 10 B B BD FD FD 4" EG2 50 4" RG26"x6" 6"x6" FCU-B 1 2 3 12 M5-01 5 M5-01 3 M5-01 GUESTROOM QQ 340 FCU-B RG2 SG1 450 24"x6" 30 30 32 32 Y Y U U W W 31 31 VV ZZ 26"x11"BD 4" FD 6"x6" 6"x6" FD 4" EG2 50 FCU-B 1 3 2 5 M5-01 12 M5-01 3 M5-01 GUESTROOM JUNIOR SUITE W/ ADA COMM. 339 VEST 305 FCU-B 26"x11" RG2 SG1 450 30 30 L L K N N 31 31 RR 29 29 SS QQ BD 4" 4" FD FD 12"x6" 12"x6" EG2 50 FCU-B 24"x6"2 1 3 5 M5-013 M5-01 12 M5-01 GUESTROOM QQ W/BALCONY 338 SG1 450 24"x6" 30 30 Y Y U U W W 29 29 VV ZZ FCU-B 26"x11" RG2 BD FD FD 4" 4" EG2 50 12"x6" 12"x6" FCU-B 1 2 3 3 M5-01 12 M5-01 5 M5-01 GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M4-01 03/22/19 MECHANICAL ENLARGED PLANS 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/4" = 1'-0"M4-01 2 GUESTROOM KING ENLARGED PLAN NORTH 1/4" = 1'-0"M4-01 3 DOUBLE QUEEN W/ TUB & CONNECTOR DOOR ENLARGED PLAN NORTH 1/4" = 1'-0"M4-01 1 KING STUDIO ENLARGED PLAN NORTH 1/4" = 1'-0"M4-01 4 GUESTROOM DOUBLE QUEEN ENLARGED PLAN NORTH 1/4" = 1'-0"M4-01 5 GUESTROOM JUNIOR SUITE W/ ADA COMM. ENLARGED PLAN NORTH 1/4" = 1'-0"M4-01 6 GUESTROOM DOUBLE QUEEN W/ BALCONY ENLARGED PLAN # PLAN NOTES: 1 GUESTROOM FAN COIL UNIT SUPPLY DUCT TO BE INTERNALLY INSULATED WITH 1" FLEXIBLE ELASTOMERIC DUCT LINER. DUCT SIZE INDICATES FREE AREA. 2 BALANCE OUTDOOR AIR TO GUESTROOM FAN COIL UNIT TO 50 CFM, TYPICAL. 3 PROVIDE DUCT ACCESS PANEL FOR FIRE DAMPER. NO. DATE DESCRIPTION