HomeMy WebLinkAboutM4-03-MECHANICAL-ENLARGED-PLANS-Rev.1AHU-1 EUH-5 EUH-6 EUH-7 26"x18" 18"x16"16"x28"16"x28"16"x28"38"x12"16"x28"OUTDOOR AIR INTAKE LOUVER EXHAUST LOUVER 21 21 23 23 26 26 28 28 30 30 D D F F L L K 31 31 20 20 29 29 27 2725 25 EE G G 22 22 24 C HH 4 M3-01 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 MECHANICAL 248 18 15 15 L-3 L-4 19 2021222324 12"x12"14"x30"14"x28" 14"x30" 18"x16" 20"x8"8"EF-4 AHU-1 TCC VFD VFD 25 BDD 4"4" 4"4" 26 27 2 M4-03 6" 32"x14"32"x14"26"x18"SG2 200 10"x6" 28 GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. LEVEL 2 16' - 0" LEVEL 1 0' - 0" LEVEL 3 32' - 0" L H 1'-0" MIN.4" 4" 4" MECHANICAL 248 DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M4-03 03/22/19 MECHANICAL ENLARGED PLANS 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/4" = 1'-0"M4-03 1 MECHANICAL ROOM ENLARGED PLAN # PLAN NOTES: 1 8" EXHAUST DUCT FROM CHEM ROOM BELOW. PROVIDE CURB AT DUCT PENETRATION THROUGH FLOOR SLAB. REFER TO SHEET M1-01C FOR CONTINUATION. 2 26"x18" KITCHEN EXHAUST UP TO KEF-1 ON LOW ROOF ABOVE. REFER TO SHEET M1-03 FOR CONTINUATION. 3 18"x16" KITCHEN EXHAUST UP TO KEF-2 ON LOW ROOF ABOVE. REFER TO SHEET M1-03 FOR CONTINUATION. 4 12"x12" DISHWASHER EXHAUST DUCT UP TO KEF-3 ON LOW ROOF. REFER TO SHEET M1-03 FOR CONTINUATION. 5 8" EXHAUST DUCT UP TO EF-2 ON LOW ROOF. REFER TO SHEET M1-03 FOR CONTINUATION. 6 20"x8" DISHWASHER EXHAUST DUCT FROM BELOW. PROVIDE CURB AT DUCT PENETRATION THROUGH FLOOR SLAB. REFER TO SHEET M1-01C FOR CONTINUATION. 7 26"x18" KITCHEN EXHAUST FROM FLOOR BELOW. REFER TO SHEET M1-01B FOR CONTINUATION. PROVIDE CURB AT DUCT FLOOR PENETRATION. 8 18"x16" KITCHEN EXHAUST FROM FLOOR BELOW. REFER TO SHEET M1-01B FOR CONTINUATION. PROVIDE CURB AT DUCT FLOOR PENETRATION. 9 16"x28" RETURN AIR DUCT FROM KITCHEN BELOW. REFER TO SHEET M1-01B FOR CONTINUATION. PROVIDE CURB AT DUCT FLOOR PENETRATION. 10 16"x28" SUPPLY AIR DUCT DOWN TO SERVE KITCHEN BELOW. REFER TO SHEET M1-01B FOR CONTINUATION. PROVIDE CURB AT DUCT FLOOR PENETRATION. 11 14"x28" MAKE-UP AIR DUCT DOWN TO KITCHEN BELOW. REFER TO SHEET M101B FOR CONTINUATION. PROVIDE CURB AT DUCT FLOOR PENETRATION. 12 14"x30" MAKE-UP AIR DUCT DOWN TO KITCHEN BELOW. REFER TO SHEET M1-01B FOR CONTINUATION. PROVIDE CURB AT DUCT FLOOR PENETRATION. 13 28"x14" MAKE-UP AIR DUCT FROM MUA-1 ON LOW ROOF ABOVE. REFER TO SHEET M1-03 FOR CONTINUATION. 14 30"x14" MAKE-UP AIR DUCT FROM MUA-2 ON LOW ROOF ABOVE. REFER TO SHEET M1-03 FOR CONTINUATION. 15 MOUNT ELECTRIC UNIT HEATER APPROXIMATELY 8'-0" A.F.F. 16 REFRIGERANT PIPING FROM CONDENSING UNITS ON LOW ROOF ABOVE. REFER TO REFRIGERANT PIPE DIAGRAMS FOR PIPE SIZES. REFER TO SHEE M2-03 FOR CONTINUATION. 17 REFRIGERANT PIPING DOWN TO SERVE DUCTLESS SPLITS ON FIRST FLOOR. REFER TO REFRIGERANT DIAGRAMS FOR PIPE SIZES. PROVIDE CURB AT REFRIGERANT FLOOR PENETRATIONS. 18 REFER TO PLUMBING AND ELECTRICAL DRAWINGS FOR EQUIPMENT, FIXTURE AND PANEL LOCATIONS IN THIS ROOM. 19 FLUE FROM AHU-1 GAS HEAT EXCHANGER. FLUE SHALL BE AL-294C OR OTHER APPROVED TYPE III VENT (POSITIVE PRESSURE), DOUBLE-WALL PER MANUFACTURER'S RECOMMENDATION. TERMINATE WITH VENT HOOD. PAINT TO MATCH. 20 INSTALL KITCHEN HOOD GREASE EXHAUST DUCTS WITHOUT DIPS OR TRAPS THAT MAY HOLD GREASE. SLOPE EXHAUST DUCT A MINIMUM OF 2 PERCENT TO DRAIN GREASE BACK TO HOOD. 21 INSTALL FIRE RATED ACCESS PANEL ASSEMBLIES IN KITCHEN HOOD EXHAUST DUCT AT EACH CHANGE IN DIRECTION AND AT MAXIMUM INTERVALS IF 12 FEET IN HORIZONTAL DUCTS. LOCATE ACCESS PANEL ON TOP OR SIDE OF DUCT. PANEL SHALL BE A MINIMUM OF 12"x12" AND SHALL BE LOCAT 22 CLEANOUTS SHALL BE INSTALLED IN HORIZONTAL GREASE DUCT AND SHALL BE PLACED NOT MORE THAN 20 FEET FROM ANY CHANGE IN DIRECTION GREATER THAN 45 DEGREES. DO NOT LOCATE CLEANOUT ON BOTTOM OF DUCT. 23 GREASE EXHAUST SHALL BE ENCLOSED FROM THE POINT AT WHICH IT PENETRATES THE CEILING TO THE OUTLET AT THE EXHAUST FAN. THE DUCT ENCLOSURE SHALL BE EITHER FIELD APPLIED OR FACTORY BUILT. 24 GREASE EXHAUST SHALL BE WELDED 16 GUAGE BLACK STEEL OR OTHER CODE APPROVED MATERIAL. 25 EF-4 TO BE INTERLOCKED WITH AHU-1. REFER TO AHU-1 CONTROL SEQUENCE. 26 TERMINATE FLUE AT SIDEWALL WITH VENT HOOD. PAINT TO MATCH WALL. 27 COMBUSTION AIR UP THROUGH ROOF. TERMINATE WITH GOOSENECK DOWN AT 12" ABOVE ROOF. 28 INSULATE EXHAUST DUCT FROM LOUVER TO BDD. NO. DATE DESCRIPTION 1 04/09/2019 LOW ROOF REV. 2 04/17/2019 EF-4 REVISION 6 10/23/19 MISC. CHANGES SCALE: 1/4" = 1'-0"2 WATER HEATER SECTION