HomeMy WebLinkAboutM5-01-MECHANICAL-DETAILS-Rev.1BASE PLY OR PLIES DECK AND INSULATION AS REQUIRED EXISTING ROOF MEMBRANE BASE FLASHING STRIP EXISTING ROOF MEMBRANE FASTNERS APPROX. 8" O.C. COUNTERFLASHING FASTENED APPOX. 18" SEAL STRIP METAL FRAME WITH INSULATION WOOD NAILER - NOM. 2x4 ALTERNATIVE FRAME LOCATION FOR HEAVY LOADS (V.I.F.)FASTEN WOOD BLOCKING TO METAL DECK WITH MECHANICAL FASTENERS FESCANT STRIP CD RL RS OUTDOOR AIR DUCT CONDENSATE DRAIN PIPE INDOOR UNIT HANGER ROD WITH VIBRATION ISOLATORS, ANCHOR TO STRUCTURE ABOVE FLEX CONNECTION MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCE FOR CONTROL BOX ACCESS HANGAR RODS (TYP OF 4) SPRING VIBRATION ISOLATORS (TYP OF 4)FLEX CONNECTION SUPPLY AIR DUCT LOW VELOCITY SUPPLY AIR DUCTWORK. TRANSITION AS REQUIRED FROM FCU TO SIZE OF DUCT NOTED ON HVAC FLOOR PLANS. DUCT LOCATION FROM FCU MAY DIFFER DUE TO TYPE AND UNIT MANUFACTURER.VRV FAN COIL UNIT (FCU) RETURN AIR DUCT WITH 1" INTERNAL INSULATION FILTER BACK GRILLE OR IF THE RETURN AIR IS DUCTED WITH NO FILTERBACK GRILLE, PROVIDE A 1" FILTER TRACK WITH SIDE ACCESS IN RETURN DUCT NEAR FCU RECTANGULAR EXHAUST DUCT SPIN-IN OR ADHESIVE FITTING W/ VOLUME DAMPER FLEX DUCT - MAXIMUM 6'-0" LENGTH AND NO MORE THAN TWO (2) 90° BENDS 12"x12"x12" HIGH SHEETMETAL PLENUM METAL PANEL SUSPENDED LAY-IN ACOUSTICAL CEILINGEXHAUST REGISTER REFER TO ARCHITECTURAL PLANS FOR ROOF CONSTRUCTION AUTO BACKDRAFT DAMPER SEE PLANS FOR DUCT SIZE EXTERNAL ALUM. WIRE POST BY UNIT MFGR. PIGTAIL CORD DISCONNECT SWITCH BY UNIT MFGR. MOTOR ALUM. HOUSING FAN BIRDSCREEN PROVIDE HOLE THRU ROOF 16" HIGH PRE-FAB CURB FLASH AND COUNTERFLASH CONDENSING UNIT EQUIPMENT RAILS (TYP OF 2) CONDUIT FOR POWER WIRING (BY DIV. 26) POWER WIRING (BEYOND) REFRIGERANT PIPING (OTHER PIPE BEYOND) ALUMINUM JACKET ON BOTH REFRIGERANT LINES 4-PIPE PIPE PORTAL WITH ALUMINUM BASE EQUAL TO PORTALS PLUS ALUM- FLASH SYSTEM ADJUSTABLE PIPE SUPPORT EQUAL TO MAPA MS STAINLESS STEEL STRUT SUPPORT STRUCTURE BEYOND 1" FLEXIBLE ELASTOMERIC LINER SEAL ALL THE WAY AROUND WITH NON-HARDENING CAULK. TRANSFER AIR DUCT. SEE PLAN SHEETS FOR VARIOUS SIZES. FRAME OPENING WITH STUDS SEE PLANS FOR GRILLE TYPE AIR GAP TO BE STUFFED WITH FIBERGLASS INSULATION 18"EZ SLEEPER PIPE SUPPORT 10' O.C. TYPICAL RUBBER MEMBRANE SEE PLAN FOR PIPE SIZE SUPPORT PIPING FROM STRUCTURE TYPICAL PACKAGED ROOFTOP UNIT PLUG VALVE UNION PIPE REDUCER PRESSURE REDUCING VALVE DIRT LEG INSTALL GROMMET AT PENETRATION THRU CABINET PAINT WEATHERPROOFING TO MATCH ROOF COLOR DOUBLE WALL DUCTWORK INSULATION TAPERED AT CENTER FOR POSITIVE DRAINAGE 2 X 2 X 1/4 BASE ANGLE ATTACHED TO ROOF CURB 18" MIN.HEIGHT ABOVE ROOFROOF RAIL PROVIDE 1 1/2 X 1 1/2 X 1/4 ANGLE FRAME. WELD ALL CONNECTIONS NOTES : 1.ALL SUPPORTS SHALL BE PRIMED AND EPOXY PAINTED. 2.TURN ROOF RAIL OVER TO GENERAL TRADES CONTRACTOR FOR INSTALLATION TO ROOF.18" MIN.HEIGHT ABOVE ROOFDUCTWORK BOARD INSULATION WITH WEATHERPROOFING ATTACH INSULATION TO DUCT USING WELDED PINS PAINT WEATHERPROOFING TO MATCH ROOF COLOR INSULATION TAPERED AT CENTER FOR POSITIVE DRAINAGE HOT DIP GALVANIZED STEEL HIGH DENSITY/HIGH IMPACT POLYPROPYLENE BASE WITH UV PROTECTION INSTALL PER MANUFACTURERS RECOMMENDATIONS ATTACHMENT PLATE WELDED DUCT TO A MINIMUM OF PREFABRICATED ROOF CURB WITH CANT. VENTED CURB EXTENSION. WATER TIGHT GROMMET ON SIDE OF LIQUID TIGHT FLEXIBLE CONDUIT UPBLAST CENTRIFUGAL EXHAUST FAN. NEMA 3R DISCONNECT FACTORY WIRED FROM MOTOR TO DISCONNECT THROUGH THE BREATHER TUBE.40" MINIMUM18 GAUGE STAINLESS STEELGREASE PAN ON ROOF CONTINUOUS AROUND FAN. SECURE TO CURB AFTER ROOF WORK IS COMPLETE. EXTENSION. VENTED CURB 18" 18" ABOVE ROOF DECK. ROOF (BY OTHERS). BIRDSCREEN. STRUCTURE BEYOND 1" FLEXIBLE ELASTOMERIC LINER SEAL ALL THE WAY AROUND WITH NON-HARDENING CAULK. TRANSFER AIR DUCT. SEE PLAN SHEETS FOR VARIOUS SIZES. AIR GAP TO BE STUFFED WITH FIBERGLASS INSULATION FRAME OPENING WITH STUDS ANGLES 1-1/2"x1-1/2"x1/8" MINIMUM; FASTENED TO SLEEVE AS REQUIRED BY U.L. LABEL; ANGLES TO LAP MASONRY OPENING MINIMUM 1". CONNECT DUCT TO DAMPER COLLAR BOTH SIDES OF PARTITION AS REQUIRED BY U.L. LABEL. "S"-SLIP TYPICAL CONNECTION TO DUCTWORK DUCT CONNECTOR - FULL WIDTH OF SLEEVE REQUIRED AT TOP ONLY FASTEN FIRE DAMPER FRAME TO SLEEVE AS REQUIRED BY U.L. LABEL NOTE: PROVIDE HINGED OR DOUBLE CATCH ACCESS DOOR SIZED AND LOCATED TO PERMIT REPLACEMENT OF FUSIBLE LINK LABELLED "FIRE DAMPER ACCESS" WALL SLEEVE; MINIMUM 16 GA. FOR DAMPERS NOT EXCEEDING 36"Wx24"H AND 14 GA. FOR LARGER SIZES FIRE RATED FLOOR OR PARTITION TOP BLADE RIVETED TO FRAME PARTITION AS SCHEDULED AIR GAP OF NON- HARDENING CAULK AIR GAP TO BE STUFFED WITH FIBERGLASS INSULATION 1/2" GAP AROUND ENTIRE PERIMETER FRAME OPENING WITH STUDS DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M5-01 03/22/19 MECHANICAL DETAILS 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 SCALE: NTS1ROOF CURB INSTALLATION DETAIL SCALE: NTS4VRF TERMINAL PIPING DIAGRAM SCALE: NTS5VRF TERMINAL INSTALLATION DETAIL SCALE: NTS3EXHAUST REGISTER DETAIL SCALE: NTS6EXHAUST FAN (FLAT) DETAIL (TYP.) SCALE: NTS7DX CONDENSING UNIT DETAIL SCALE: NTS8BELOW CEILING TRANSFER DUCT SCALE: NTS9GAS PIPING DETAIL SCALE: NTS10RTU GAS PIPING CONNECTION SCALE: NTS13DUCTWORK ROOF SUPPORTS DETAIL SCALE: NTS11KITCHEN EXHAUST FAN DETAIL SCALE: NTS2ABOVE CEILING TRANSFER DUCT SCALE: NTS12FIRE DAMPER INSTALLATION DETAIL (TYP.) SCALE: NTS14DUCT/PIPE PENETRATION DETAIL NO. DATE DESCRIPTION