HomeMy WebLinkAboutM6-09-VRF-PIPING-AND-WIRING-DIAGRAMS-Rev.270.0 ft [5] 3/4" 7/8 x 3/8 x 6.0 ft [2] 1/2" 1/4 x 45.0 ft [3] 1/2" 1/4 x 24.0 ft [3] 1/2" 1/4 x 19.0 ft [3] 1/2" 1/4 x 42.0 ft [3] 1/2" 1/4 x 48.0 ft [3] 1/2" 1/4 x 41.0 ft [3] 1/2" 1/4 x 50.0 ft [3] 1/2" 1/4 x 30.0 ft [4] 1/2" 1/4 x CU 5-2CU 5-2 REYQ96TAYDUREYQ96TAYDU BSB 5-2BSB 5-2 BS10Q54TVJBS10Q54TVJ AA FCU-B Corrid...FCU-B Corrid... 5th Floor5th Floor FXMQ12PBVJUFXMQ12PBVJU BB FCU-B 523FCU-B 523 FXMQ12PBVJUFXMQ12PBVJU CC FCU-B 524FCU-B 524 FXMQ12PBVJUFXMQ12PBVJU DD FCU-B 525FCU-B 525 FXMQ12PBVJUFXMQ12PBVJU EE FCU-B 526FCU-B 526 FXMQ12PBVJUFXMQ12PBVJU FF FCU-B 528FCU-B 528 FXMQ12PBVJUFXMQ12PBVJU GG FCU-B 527FCU-B 527 FXMQ12PBVJUFXMQ12PBVJU HH FCU-B 529FCU-B 529 FXMQ12PBVJUFXMQ12PBVJU II FCU-A 507FCU-A 507 HousekeepingHousekeeping FXMQ09PBVJUFXMQ09PBVJU JJ Drawing No Date 5/7/2019 REYQ96TAYDU VRV-IV TA Air cooled heat recovery CU 5-2 Title Piping schematics Project Carmichael Hotel USA Client L1, L2, L3 21.1A 3ph L1, L2 1A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 0.6A 1ph OUT F1,F2 to centralized controller IN F1,F2 OUT F1,F2 IN F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 P1,P2 P1,P2 P1,P2 P1,P2 P1,P2 P1,P2 P1,P2 P1,P2 P1,P2 CU 5-2 REYQ96TAYDU REYQ96TAYDU BSB 5-2 BS10Q54TVJ ABCDEFGHIJ FCU-B Corrid... FXMQ12PBVJU BRC1E73 (1) FCU-B 523 FXMQ12PBVJU BRC1E73 (1) FCU-B 524 FXMQ12PBVJU BRC1E73 (1) FCU-B 525 FXMQ12PBVJU BRC1E73 (1) FCU-B 526 FXMQ12PBVJU BRC1E73 (1) FCU-B 528 FXMQ12PBVJU BRC1E73 (1) FCU-B 527 FXMQ12PBVJU BRC1E73 (1) FCU-B 529 FXMQ12PBVJU BRC1E73 (1) FCU-A 507 FXMQ09PBVJU BRC1E73 (1) Drawing No Date 5/7/2019 REYQ96TAYDU VRV-IV TA Air cooled heat recovery CU 5-2 Title Wiring schematics Project Carmichael Hotel USA Client 67.0 ft [6] 3/4" 7/8 x 3/8 x 50.0 ft [3] 1/2" 1/4 x 66.0 ft [4] 1/2" 1/4 x 80.0 ft [6] 1/2" 1/4 x 54.0 ft [4] 1/2" 1/4 x 60.0 ft [4] 1/2" 1/4 x 66.0 ft [4] 1/2" 1/4 x 78.0 ft [4] 1/2" 1/4 x 72.0 ft [4] 1/2" 1/4 x CU 5-3CU 5-3 REYQ96TAYDUREYQ96TAYDU BSB 5-3BSB 5-3 BS8Q54TVJBS8Q54TVJ AA FCU-B 522FCU-B 522 FXMQ12PBVJUFXMQ12PBVJU BB FCU-B 521bFCU-B 521b Suite 521Suite 521 FXMQ12PBVJUFXMQ12PBVJU CC FCU-B 521aFCU-B 521a Suite 521Suite 521 FXMQ12PBVJUFXMQ12PBVJU DD FCU-B 520FCU-B 520 FXMQ12PBVJUFXMQ12PBVJU EE FCU-B 519FCU-B 519 FXMQ12PBVJUFXMQ12PBVJU FF FCU-B 517FCU-B 517 FXMQ12PBVJUFXMQ12PBVJU GG FCU-B 518FCU-B 518 FXMQ12PBVJUFXMQ12PBVJU HH FCU-B 515FCU-B 515 FXMQ12PBVJUFXMQ12PBVJU Drawing No Date 5/7/2019 REYQ96TAYDU VRV-IV TA Air cooled heat recovery CU 5-3 Title Piping schematics Project Carmichael Hotel USA Client DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M6-09 03/22/19 VRF PIPING AND WIRING DIAGRAMS 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 SCALE: NTS1CU-5-2 PIPING SCALE: NTS2CU-5-2 WIRING SCALE: NTS3CU-5-3 PIPING NO. DATE DESCRIPTION 3 05/08/2019 VRF REVISIONS