HomeMy WebLinkAboutM6-13-VRF-PIPING-AND-WIRING-DIAGRAMS-Rev.237.0 ft [5] 3/4" 7/8 x 3/8 x 69.0 ft [3] 1/2" 1/4 x 92.0 ft [3] 1/2" 1/4 x 93.0 ft [3] 1/2" 1/4 x 99.0 ft [5] 1/2" 1/4 x 119.0 ft [6] 1/2" 1/4 x 110.0 ft [4] 1/2" 1/4 x 116.0 ft [4] 1/2" 1/4 x CU 6-4CU 6-4 REYQ96TAYDUREYQ96TAYDU BSB 6-4BSB 6-4 BS8Q54TVJBS8Q54TVJ AA FCU-B 616FCU-B 616 FXMQ12PBVJUFXMQ12PBVJU BB FCU-B 613FCU-B 613 FXMQ12PBVJUFXMQ12PBVJU CC FCU-B 614FCU-B 614 FXMQ12PBVJUFXMQ12PBVJU DD FCU-B 612aFCU-B 612a Suite 612Suite 612 FXMQ12PBVJUFXMQ12PBVJU EE FCU-B 612bFCU-B 612b Suite 612Suite 612 FXMQ12PBVJUFXMQ12PBVJU FF FCU-B 611FCU-B 611 FXMQ12PBVJUFXMQ12PBVJU GG FCU-B 610FCU-B 610 FXMQ12PBVJUFXMQ12PBVJU HH Drawing No Date 5/7/2019 REYQ96TAYDU VRV-IV TA Air cooled heat recovery CU 6-4 Title Piping schematics Project Carmichael Hotel USA Client L1, L2, L3 21.1A 3ph L1, L2 0.8A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph L1, L2 1.4A 1ph OUT F1,F2 to centralized controller IN F1,F2 OUT F1,F2 IN F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 F1,F2 P1,P2 P1,P2 P1,P2 P1,P2 P1,P2 P1,P2 P1,P2 CU 6-4 REYQ96TAYDU REYQ96TAYDU BSB 6-4 BS8Q54TVJ ABCDEFGH FCU-B 616 FXMQ12PBVJU BRC1E73 (1) FCU-B 613 FXMQ12PBVJU BRC1E73 (1) FCU-B 614 FXMQ12PBVJU BRC1E73 (1) FCU-B 612a FXMQ12PBVJU BRC1E73 (1) FCU-B 612b FXMQ12PBVJU BRC1E73 (1) FCU-B 611 FXMQ12PBVJU BRC1E73 (1) FCU-B 610 FXMQ12PBVJU BRC1E73 (1) Drawing No Date 5/7/2019 REYQ96TAYDU VRV-IV TA Air cooled heat recovery CU 6-4 Title Wiring schematics Project Carmichael Hotel USA Client OUT F1,F2 OUT F1,F2 OUT F1,F2 L,N Ethernet 100BASE-TX L,N L,N CPEV/FCPEV - Max distance is 164ft/50m CU 3-1 (11) REYQ144TAYDU CU 3-2 (9) REYQ96TAYDU CU 3-3 (8) REYQ96TAYDU CU 3-4 (7) REYQ96TAYDU CU 4-1 (11) REYQ144TAYDU CU 4-2 (9) REYQ96TAYDU CU 4-3 (8) REYQ96TAYDU Itouch Manager DCM601A71 CU 4-4 (7) REYQ96TAYDU CU 5-1 (11) REYQ144TAYDU CU 5-2 (9) REYQ96TAYDU CU 5-3 (8) REYQ96TAYDU CU 5-4 (7) REYQ96TAYDU CU 6-1 (11) REYQ144TAYDU CU 6-2 (9) REYQ96TAYDU i-Touch Manager DIII... DCM601A72 CU 6-3 (8) REYQ96TAYDU CU 6-4 (7) REYQ96TAYDU i-Touch Manager DIII... DCM601A72 Drawing No Date 3/5/2019 Control Group Title Controller wiring schematics Project Carmichael Hotel USA Client DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M6-13 03/22/19 VRF PIPING AND WIRING DIAGRAMS 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 SCALE: NTS1CU-6-4 PIPING SCALE: NTS2CU-6-4 WIRING SCALE: NTS3THIRD THROUGH SIXTH FLOOR CONTROLLER WIRING NO. DATE DESCRIPTION 3 05/08/2019 VRF REVISIONS