Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P-100-Plumbing-Under-Floor-Plan-Rev.6
5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J J L L P P T T 1 1 Y Y U U A A 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE G G XX SS VV 2 23 3 10 10 22 22 24 24 B B QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 0.9 0.9 6.7 6.7 W ST ST W STSTFFW STSTST WSGWWSTSTST ST WSTST W WST STWWWSTWW WW W W STST 4" ST 4" ST 6" ST 4" ST4" ST 4" ST 4" ST 6" ST 6" ST 6" ST 6" ST 8" ST 4" ST 4" ST 8" ST 6" ST 4" ST 4" ST 4" ST STST 6" ST 4" ST 6" ST 6" ST 4" ST 6" ST 3" ST 4" ST 4" ST 4" ST 4" ST 6" ST 4" ST 6" ST 4" ST 4" ST 6" ST 6" ST 4" ST 6" ST6" ST 4" ST 2 4 3 22 4 2 3 2 2 2 1 5 5 3 2 4 2 2 5 2 2 3 5 8" STORM INV. EL. -4'-2" B.F.F. 7 6" STORM INV. EL. -4'-0" B.F.F. 7 6" STORM INV. EL. -4'-0" B.F.F. 7 6" STORM INV. EL. -4'-0" B.F.F. 7 8" W 6" W 6" W 6" W 4" W 4" W 4" W 4" W 2" W 6" W 3" W 2" W 4" W 2" W 4" W 3" WWW 4" W 4" W 4" W 2" W 4" W 4" W 6" W4" W 6" W 4" W 4" W 6" W 6" W 6" W 3" W 4" W 4" W 9 10 10 8 12 12 16 17 17 16 10 10 18 16 21 18 16 19 18 16 17 17 16 10 8" WASTE INV. EL. -4'-0" B.F.F. 7 20 22 6" WASTE INV. EL. -4'-0" B.F.F. 20 4" SANITARY GREASE INV. EL. -4'-0" B.F.F. 21 2216 16 16 17 18 18 18 26 10 16 18 19 10 9 16 26 18 16 10 17 4" W3" W3" W W 9 27 2827 12 8 12 12 11 21 22 16 3" W 14 6" F 6" F 6" CW 77 29 30 31 7 7 3" V 7 13 24 12 12 3" W 3" SG 4" SG 4" SG 32 SG 24 38 24 4" W 4" W4" W3" W 4" W G 39 PIPE SLEEVE (TYP) 3" W 3" W 4" W 4" W 3" W 3" W 3" W 40 6 ST STST ST F.F.E.=834.00' F.F.E.=832.83' F.F.E.=834.00' F.F.E.=834.00' 11 4" ST 25 4" W 11 8" BEER CONDUIT 6" SODA CONDUIT 8" BEER CONDUIT6" SODA CONDUIT 6" SODA CONDUIT 8" BEER CONDUIT 6" SODA CONDUIT 8" BEER CONDUIT 43 44 43 44 44 43 48 47 27 3" W 49 49 6" W 11 12 4 12 12 16 9 12 9 9 10 10 11 14 12 12 11 16 461612 10 45 34 3432 36 45 33 50 45 34 32 35 34 32 4534 51 36 2452 24 24 24 24 24 24 36 SGSG 4" SG 4" W4" W 4" W 3" SG 4" W 3" W 4" W 4" W SG4" SG 2" SG 3" W 4" W 4" W 44 4422 6" W 6" W WW6 A. REFER TO SHEET M-000 FOR GENERAL PLUMBING SYMBOLS, LEGENDS AND ABBREVIATIONS. B. REFER TO MP SERIES DRAWINGS FOR CONDENSATE DRAIN PIPING WORK. C. FIRE BARRIER PENETRATIONS; WHERE PIPES PASS THROUGH THE FIRE RATED WALLS, PARTITIONS, CEILINGS AND FLOORS, MAINTAIN THE FIRE RATED INTEGRITY. REFER TO DIVISION 7 FOR SPECIAL SEALERS AND MATERIALS. REFER TO BUILDING CODE SUMMARY AND LIFE SAFETY PLANS ON ARCHITECTURAL DRAWINGS FOR FIRE RATED ASSEMBLIES. D. PROVIDE A CLEANOUT AT THE BASE OF ALL SANITARY SOIL OR WASTE STACKS AND STORM RISERS. E. INSTALL PIPING AS HIGH AS POSSIBLE. F. REFER TO FOOD SERVICE DRAWINGS FOR ADDITIONAL REQUIREMENTS. G. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. H. ALL PIPING AND MATERIALS INSTALLED ABOVE THE FIRST FLOOR AND SECOND FLOOR CEILINGS SHALL BE PLENUM RATED OR BE WRAPPED WITH A HIGH TEMPERATURE INSULATION BLANKET OR WRAP MEETING THE FLAME SPREAD AND SMOKE DEVELOPED RATING OF THE BUILDING CODE. PRODUCT SHALL BE 1/2" THICK FOIL FACED WITH A DENSITY OF 6 PCF. PRODUCT SHALL BE SUITABLE FOR OPERATION AT TEMPERATURES UP TO 2300°F. GENERAL PLUMBING NOTES DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc ISSUED FOR CONSTRUCTIONP-100 08/27/18 Plumbing Under Floor Plan 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 781-6200 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0" Plumbing Under Floor Plan1 N 0 16'8'4' SHEET KEYNOTES 1 3"ST UP. 2 4"ST UP. 3 6"ST UP. 4 4"ST UP TO FCO. 5 4"ST UP TO ECO. 6 3"V UP FROM GREASE INTERCEPTOR. 7 SEE SITE/CIVIL DRAWINGS FOR CONTINUATION. 8 2"W UP. 9 3"W UP. 10 4"W UP. 11 4"W UP TO FCO. 12 3"W WITH P-TRAP UP TO FLOOR SINK. 13 2"W, 2" VENT, 1"CW AND 3/4"HW UP TO SINK. 14 2"W UP TO SINK. 15 NOT USED. 16 2"W WITH P-TRAP UP TO FLOOR DRAIN. 17 4"W UP TO WATER CLOSET. 18 2"W UP TO LAVATORY. 19 2"W UP TO URINAL. 20 4"W UP TO ECO. 21 3"W WITH P-TRAP UP TO MOP BASIN. 22 2"V UP. 23 NOT USED. 24 3/4"CW & 3/4"HW UP. 25 4"W UP TO WALL CLEANOUT. 26 2"W WITH P-TRAP UP TO SHOWER DRAIN. 27 3"W WITH P-TRAP UP TO FLOOR DRAIN. 28 3"W WITH P-TRAP UP TO FLOOR DRAIN. 29 6" INCOMING DOMESTIC WATER SERVICE. 30 6" INCOMING FIRE SERVICE. 31 6"F DOWN TO FIRE DEPARTMENT CONNECTION. 32 3"SG WITH P-TRAP UP TO FLOOR SINK. 33 4"SG WITH P-TRAP UP TO FLOOR TROUGH. 34 2"SG WITH P-TRAP UP TO FLOOR DRAIN. 35 2"SG WITH P-TRAP UP TO FLOOR SINK. 36 4"SG UP TO FCO. 37 NOT USED. 38 1/2"CW UP. 39 INCOMING GAS SERVICE UP. 40 4"SG UP TO ECO. 41 NOT USED. 42 NOT USED. 43 6" SODA CONDUIT UP. 44 8" BEER CONDUIT UP. 45 2"SG UP TO HAND SINK. 46 4"W WITH P-TRAP UP TO FLOOR TROUGH. 47 1 1/4"CW (NPW) FROM ABOVE. 48 1 1/4"CW (NPW) UP TO IRRIGATION VALVE BOX. TERMINATE WITH SHUT-OFF VALVE. 49 2"W UP. 50 3"SG UP TO FCO. 51 4"SG WITH P-TRAP UP TO FLOOR SINK. 52 3/4"CW UP. REVISIONS NO. DATE DESCRIPTION 09/12/2018 ADD #2 09/20/2018 ADD #4 10/02/2018 ADD #5 1 08/27/2018 Issued for Construction 3 12/03/2018 General Revisions 6 03/22/2019 Revision 8