Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P-102-Plumbing-Floor-Plan-Level-2-Rev.7
DN 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J J L L P P T T 1 1 Y Y U U A A 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE G G XX SS VV 2 23 3 10 10 22 22 24 24 B B QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 0.9 0.9 6.7 6.7 BALLROOM 246 STAIR #1 2ST1 SERVICE 236 WOMEN 238 JAN 245 HOLDING KITCHEN 237 STORAGE 241 COATS 240 MEN 239 CORRIDOR 247 LUGGAGE 232 F.O. MANAGER 231 VEST 228 WORK 227 UNISEX 225 WOMEN 223 MEN 222 JAN 224 F&B 219 CATERING 218 FURNITURE STORAGE 217 STAIR #2 2ST2 REVENUE 214 BOARDROOM 211 LIBRARY 210 MEETING 201 COVERED PORCH 205 STORAGE 206 RETAIL 226 WELCOME DESK 230 BELL ACCESS 233 ELEVATOR LOBBY 208 SERV 229 VEST 221 PREFUNCTION 242 CORRIDOR 235 A/V ROOM 244 MECHANICAL 248 VESTIBULE 204 CART STOR 209CART STOR. 216 CORRIDOR 234 Room 200 BREAKOUT 243 WW WWWWW W ST STW ST W W3 P-502 GM 212 VEST 213 CORR 220 P-401 2 P-403 1 P-401 1 3"FD-2 1" HWR 3/4" HWR 3/4" HWR1 1/4" HWR 1 1/4" HWR 3/4" HWR 3/4" HWR3/4" HWR 3/4" HWR3/4" HWR 3/4" HWR 3/4" HWR 3/4" HWR EWC-1 ST 6" ST 4" ST4" ST 4" ST 6" ST 3" ST 3" ST 3" ST 3" ST 3" ST 4" ST 4" ST 4" ST 4" ST 4" ST 4" ST 4" ST 4" ST 4" ST 4" ST 4" ST 124 3 4 3 1 2 3 5 5 5 5 3 7 5 5 5 5 6 9 8 9 9 9 9 8 8 8 10 10 CO 10 10 CO CO 37CO (FOR SANITARY ABOVE CEILING) SEE 1/ P-404 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 2/ P-404 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 1/ P-418 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 2/ P-405 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 1/ P-406 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 2/ P-406 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 1/ P-407 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 1/ P-413 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 2/ P-412 FOR ENLARGED UNIT PLAN(FOR SANITARY ABOVE CEILING) SEE 1/ P-412 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 1/ P-408 FOR ENLARGED UNIT PLAN (FOR SANITARY ABOVE CEILING) SEE 2/ P-408 FOR ENLARGED UNIT PLAN 11 1213 1112 1112 1412 11121112 1112 13 1112 11 12 13 CO 1112 13 1112 11 12 CO 12 11 15 15 15 15 1515 15 15 1515 15 15 15 15 1515 15 3/4" HWR 3/4" HWR 3/4" HWR 3/4" HWR 3/4" HWR 13 20 21 22 22 23 12 11 13 24 25 11 1222 21 20 23 4" V 21 26 23 20 23 24 21 22 22 4" W 11 13 22 11 12 4" W 13 23 20 22 21 11 12 2" V 4" W 27 28 1" HWR(140°) 1 1/2" HW(140°) 1" HWR 2" HW 3" CW 1" SCW 5 3 P-402 2 P-402 3 2" G (2 PSI) 29 30 G (2 PSI)3232 34 31 3232 1 1/2" HWR 1 1/4" HWR 32 32 32 1" HWR 33 33 33 33 3 P-502 32(TYP FOR 6) 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 33333333333333333333333333333333 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3"AD-2 3333 33 3"AD-2 3"AD-2 3"AD-2 36 WH-1 10 WH-1 37 38 CO 39 39 39 39 39 39 39 1" G (2 PSI) 40 2"FD-1 WB-1 41 8 1/2" CW1/2" HW1 1/2" V WHA-AWHA-A 8 G (7"W.C.)G (7"W.C.)3/4" G (7"W.C.) A. REFER TO SHEET M-000 FOR GENERAL PLUMBING SYMBOLS, LEGENDS AND ABBREVIATIONS. B. REFER TO MP SERIES DRAWINGS FOR CONDENSATE DRAIN PIPING WORK. C. FIRE BARRIER PENETRATIONS; WHERE PIPES PASS THROUGH THE FIRE RATED WALLS, PARTITIONS, CEILINGS AND FLOORS, MAINTAIN THE FIRE RATED INTEGRITY. REFER TO DIVISION 7 FOR SPECIAL SEALERS AND MATERIALS. REFER TO BUILDING CODE SUMMARY AND LIFE SAFETY PLANS ON ARCHITECTURAL DRAWINGS FOR FIRE RATED ASSEMBLIES. D. PROVIDE A CLEANOUT AT THE BASE OF ALL SANITARY SOIL OR WASTE STACKS AND STORM RISERS. E. INSTALL PIPING AS HIGH AS POSSIBLE. F. REFER TO FOOD SERVICE DRAWINGS FOR ADDITIONAL REQUIREMENTS. G. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. H. ALL PIPING AND MATERIALS INSTALLED ABOVE THE FIRST FLOOR AND SECOND FLOOR CEILINGS SHALL BE PLENUM RATED OR BE WRAPPED WITH A HIGH TEMPERATURE INSULATION BLANKET OR WRAP MEETING THE FLAME SPREAD AND SMOKE DEVELOPED RATING OF THE BUILDING CODE. PRODUCT SHALL BE 1/2" THICK FOIL FACED WITH A DENSITY OF 6 PCF. PRODUCT SHALL BE SUITABLE FOR OPERATION AT TEMPERATURES UP TO 2300°F. GENERAL PLUMBING NOTES DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc ISSUED FOR CONSTRUCTIONP-102 08/27/18 Plumbing Floor Plan Level 2 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 781-6200 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0" Plumbing Floor Plan Level 21 N 0 16'8'4' SHEET KEYNOTES 1 6"ST DOWN. 2 6"ST UP. 3 4"ST DOWN. 4 4"ST UP. 5 4"ST UP TO 4" ROOF DRAIN (RD-1) AND 4" OVERFLOW DRAIN (OFD-1). 6 4"ST UP AND DOWN. 7 6"ST UP AND DOWN. 8 3"ST UP TO 3" ROOF DRAIN (RD-1) AND 3" OVERFLOW DRAIN (OFD-1). 9 3"ST UP TO 3" AREA DRAIN (AD-1). 10 3"ST DOWN. 11 4"W UP. 12 4"V UP. 13 4"W DOWN. 14 4"W UP & DOWN. 15 3/4"HWR UP. 20 2"W WITH P-TRAP UP TO SHOWER DRAIN. 21 2"W UP TO LAVATORY. 22 3"W UP TO WATER CLOSET. 23 2"V UP. 24 3"W DOWN. 25 4"W DOWN, 4"V RISE. 26 2"W WITH P-TRAP UP TO BATH TUB. 27 1 1/2"V DOWN. 28 3"V UP & DOWN. 29 2"G (2 PSI) FROM BELOW. 30 2"G (2 PSI) UP. 31 3/4"G (7" W.C.) DROP, VALVE AND CAP FOR FUTURE. 32 HWR BALANCING VALVE STATION, SET FOR 1 GPM. 33 REFER TO DRAWING A2-07 FOR ADDITIONAL INFORMATION. 34 2"W DOWN, 1 1/2"V RISE, 1/2"CW FROM BELOW. 35 NOT USED. 36 1"HWR(140°) AND 1 1/2"HW(140°) FROM BELOW. 37 3/4"CW FROM BELOW. 38 3" WASTE STACK VENT. 39 4"RD-1 AND 4"OFD-1 UNDER PEDESTAL SUPPORTED DECK PAVERS. 40 1"G (2 PSI) DROP, PROVIDE GAS PRESSURE REGULATOR 2 PSI TO 14" W.C. 396 MBH. 41 2" WASTE DOWN, 1 1/2" VENT RISE, 1/2"CW AND 1/2"HW DROP. REVISIONS NO. DATE DESCRIPTION 09/12/2018 ADD #2 09/20/2018 ADD #4 10/02/2018 ADD #5 1 08/27/2018 Issued for Construction 4 02/22/2019 RFI-40 6 03/22/2019 Revision 8 8 12/11/2019 Revision 21 8 8