Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P-103-Plumbing-Floor-Plan-Level-3-Rev.3
5588111112121717212123232626282830303232DDFFJJLLPPTT11YYUUAA99441818KKNN77WW3131RR2020161615152929272725251414661313EEGGXXSSVV2233101022222424BBQQMMZZ1919CCHH9.29.2L.5L.5A.7A.70.90.96.76.7FITNESS310CORRIDOR301GUESTROOMJUNIOR SUITEW/ ADA COMM.339GUESTROOMKING337GUESTROOMKING335GUESTROOMKING333GUESTROOMKING331GUESTROOMKING329GUESTROOMKING327HOUSEKEEPING307ELEVATORLOBBY308VEST305STAIR #23ST2GUESTROOMQQ340GUESTROOMQQ W/BALCONY338GUESTROOMKING336GUESTROOMKING334ADAGUESTROOMKING W/ ADACOMM.332GUESTROOMKING330GUESTROOMKING328GUESTROOMKING326GUESTROOMKING325GUESTROOMKING324GUESTROOMKING323GUESTROOMQQ W/ ADACOMM.322ELEC306GUESTROOMKING320GUESTROOMKING319GUESTROOMKING318GUESTROOMKING316GUESTROOMQQ314ADAGUESTROOMLUXURY SUITEB312GUESTROOMKING STUDIO311GUESTROOMKING STUDIO310GUESTROOMKING313STAIR #13ST1MECH304CORRIDOR302CORRIDOR303UnoccupiedUnoccupied4"OFD-14"RD-14"OFD-14"RD-14"OFD-14"RD-13"VTR3P-5025575151514325755651555567SEE 1/ P-404 FORENLARGED UNIT PLANSEE 2/ P-404 FORENLARGED UNIT PLANSEE 2/ P-404 FORENLARGED UNIT PLANSEE 1/ P-418 FORENLARGED UNIT PLANSEE 1/ P-418 FORENLARGED UNIT PLANSEE 2/ P-405 FORENLARGED UNIT PLANSEE 2/ P-405 FORENLARGED UNIT PLANSEE 1/ P-406 FORENLARGED UNIT PLANSEE 1/ P-406 FORENLARGED UNIT PLANSEE 2/ P-406 FORENLARGED UNIT PLANSEE 2/ P-406 FORENLARGED UNIT PLANSEE 1/ P-407 FORENLARGED UNIT PLANSEE 1/ P-407 FORENLARGED UNIT PLANSEE 1/ P-413 FORENLARGED UNIT PLANSEE 1/ P-413 FORENLARGED UNIT PLANSEE 2/ P-413 FORENLARGED UNIT PLANSEE 2/ P-413 FORENLARGED UNIT PLANSEE 2/ P-412 FORENLARGED UNIT PLANSEE 2/ P-412 FORENLARGED UNIT PLANSEE 1/ P-412 FORENLARGED UNIT PLANSEE 1/ P-408 FORENLARGED UNIT PLANSEE 2/ P-408 FORENLARGED UNIT PLANSEE 2/ P-408 FORENLARGED UNIT PLANSEE 1/ P-409 FORENLARGED UNIT PLANSEE 1/ P-409 FORENLARGED UNIT PLANSEE 1/ P-416 FORENLARGED UNIT PLANSEE 2/ P-410 FORENLARGED UNIT PLANSEE 1/ P-410 FORENLARGED UNIT PLANSEE 2/ P-411 FORENLARGED UNIT PLAN554"OFD-14"RD-13"VTR4"RD-24"OFD-24"OFD-24"RD-24"RD-24"OFD-24"RD-24"OFD-24"RD-24"OFD-24"OFD-24"RD-23"AD-13"AD-13"RD-13"OFD-13"OFD-13"RD-13"RD-13"OFD-13"RD-13"OFD-1GUESTROOMLUXURY SUITEA3213P-5022" G (2 PSI)1" G (2 PSI)1" G (2 PSI)G (2 PSI)89103"AD-13"AD-13"AD-13"AD-111A. REFER TO SHEET M-000 FOR GENERAL PLUMBING SYMBOLS, LEGENDS AND ABBREVIATIONS.B. REFER TO MP SERIES DRAWINGS FOR CONDENSATE DRAIN PIPING WORK.C. FIRE BARRIER PENETRATIONS; WHERE PIPES PASS THROUGH THE FIRE RATED WALLS, PARTITIONS, CEILINGS AND FLOORS, MAINTAIN THE FIRE RATED INTEGRITY. REFER TO DIVISION 7 FOR SPECIAL SEALERS AND MATERIALS. REFER TO BUILDING CODE SUMMARY AND LIFE SAFETY PLANS ON ARCHITECTURAL DRAWINGS FOR FIRE RATED ASSEMBLIES.D. PROVIDE A CLEANOUT AT THE BASE OF ALL SANITARY SOIL OR WASTE STACKS AND STORM RISERS.E. INSTALL PIPING AS HIGH AS POSSIBLE.F. REFER TO FOOD SERVICE DRAWINGS FOR ADDITIONAL REQUIREMENTS.G. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR.H. ALL PIPING AND MATERIALS INSTALLED ABOVE THE FIRST FLOOR AND SECOND FLOOR CEILINGS SHALL BE PLENUM RATED OR BE WRAPPED WITH A HIGH TEMPERATURE INSULATION BLANKET OR WRAP MEETING THE FLAME SPREAD AND SMOKE DEVELOPED RATING OF THE BUILDING CODE. PRODUCT SHALL BE 1/2" THICK FOIL FACED WITH A DENSITY OF 6 PCF. PRODUCT SHALL BE SUITABLE FOR OPERATION AT TEMPERATURES UP TO 2300°F.GENERAL PLUMBING NOTESDRAWING NO.DATECDG PROJECT NO.DRAWING TITLE3555 NW 58TH StreetSuite 700-WOklahoma City, OK 73112T: 405.848.9549F: 405.848.9783www.gsb-inc.comCopyright ©GSB, Inc ISSUED FOR CONSTRUCTIONP-10308/27/18Plumbing Floor Plan Level 317089CARMEL, INCARMEL, IN2018ARCHITECTGSB, INC3555 NW 58th Street, Suite 700WOklahoma City, OK 73112405 / 848-9549CIVIL ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 706-2075STRUCTURAL ENGINEERStructurePoint7260 Shadeland StationIndianapolis, IN 46256317 / 547-5580MEP ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 781-6200INTERIOR DESIGNERHBA Hirsch Bedner Associates171 17th Street NW, Suite 600Atlanta, GA 30363404 / 873-4379FOOD SERVICE CONSULTANTRicca Newmark Design5325 South Valentia WayGreenwood Village, CO 80111303 / 928-1333 1/8" = 1'-0"Plumbing Floor Plan Level 31016'8'4'NSHEET KEYNOTES1 4" STORM DRAIN UP AND DOWN.2 4"CW-HIGH PRESSURE UP AND DOWN.3 1 1/2"HWR UP AND DOWN.4 3"G (2 PSI) UP AND DOWN.5 4" WASTE STACK, 4" VENT STACK, 1"CW AND 1"HW FROM ABOVE, 3/4"HWRDOWN.6 4" WASTE STACK, 4" VENT STACK, 1 1/4"CW AND 1"HW FROM ABOVE, 3/4"HWDOWN.7 6" STORM DRAIN UP AND DOWN.8 2"G (2 PSI) FROM BELOW.9 GAS PRESSURE REGULATOR, 2 PSI TO 14" W.C., 265.8 MBH.10 GAS PRESSURE REGULATOR, 2 PSI TO 14" W.C., 402.9 MBH.11 3" WASTE STACK VENT.REVISIONSNO. DATE DESCRIPTION09/12/2018 ADD #21 08/27/2018 Issued for Construction6 03/22/2019 Revision 86