P-401-Plumbing-Enlarged-Plans-Rev.6
MM 21 21 23 23 26 26 28 28 Y Y U U W W RR 29 29 27 2725 25 XX SS VV QQ ZZ C17 C13 C16 C14 C13 C12.1 C11 C7 C4 19 14 13 3"FS-1 FCO 3"FS-1 3"FS-1 FCO16 17 15 CO 15 17 3" W 2" W 18 3" W 3" W 3/4" HWR(140°) 3" W3/4" HW(140°) 3/4" HW 3/4" CW 3/4" HWR WC-2 WHA-A WC-2 2"FD-1 L-1SU-1 2"FD-3UR-2 2"FD-1L-1 WHA-A 2"FD-1 WC-2 WC-1 WHA-A 2"FD-1 SU-1 2"FD-3 2"FD-1 MB-1 FCO 22 ST4" ST 23 4" ST 22 23 FCO 2425 26 FEINSTEIN'S CLUB 110 PRIVATE DINING 111 RECEPTION 109 JANITOR 137 CORRIDOR 139 SERVICE 136 WOMEN'S LOCKER 135 MEN'S LOCKER 134 UNISEX TLT 116 GREEN 115 SERVICE 114 CORRIDOR 122 BAR 112 3"FS-1 3"FS-1 C28 C28.1 C27 C29 A119 C8 3/4" HWR(140°) 1" HW(140°) 3/4" HW 3/4" CW 38 20 20 20 1 1/2" V 2" V 24 1 1/2" HW 3/4" HWR 1 1/2" CW 3/4" HWR(140°) 1" HW(140°)27 3132 34 2" CW 2" V2" V 2" V 4" W W293632 37 2" V 30 35 34 282932 37 4" W 7173 273130 1 1/2" HW 3/4" HWR 2" CW 3/4" HWR(140°) 1" HW(140°) 33 30 2" V 5454 555556 3" W 57 58 59 60 59 61 30 55 CO 24 24 24 24 24 4" ST 3" ST 3" ST 4" ST 3" ST 3" ST 4" ST 3" ST COSTST 24 24 24 ST ST 3" ST CO 4" ST 3" ST 4" ST 3" ST 8" BEER CONDUIT6" SODA CONDUIT 6263 65 64 3/4" CW 67 68 30 1/2" HW 1/2" CW 1 1/2" V 72 70 30 69 70 30 69 L-1 L-1 26 26 Y Y W W 27 27 D13 D12 D11 D8 D7.1 D4 D2 10 9 111413 9 20 D5 D8 D10 3"FS-13"FS-1 D8 9 12 26 26 28 28 L L 27 27 HH MECHANICAL 248 DTMV-2 DHWST-4 DHWST-3 DET-2 DWH-3 DWH-4 WS-1WS-1 BRINE TANK 3"FD-2 3"FD-2 3"FD-2 SALT STORAGE AREA 6" ST 4" ST 4" ST ST STCO G (2 PSI) 1 1/2" G (2 PSI) 6 144 5 5 8 DHWRP-6 DHWRP-5 3" SCW 3" CW 3" SCW 7 8 1" HWR(140°)3" SCW 4" ST1" HWR 1" HWR(140°) 1 1/2" HW(140°) 1 1/2" HWR 1" SCW 3" HW DHWRP-3 DHWRP-48 3" HW(140°) 3" SCW 8 8 2 3 21 44 8 A. REFER TO SHEET M-000 FOR GENERAL PLUMBING SYMBOLS, LEGENDS AND ABBREVIATIONS. B. REFER TO MP SERIES DRAWINGS FOR CONDENSATE DRAIN PIPING WORK. C. FIRE BARRIER PENETRATIONS; WHERE PIPES PASS THROUGH THE FIRE RATED WALLS, PARTITIONS, CEILINGS AND FLOORS, MAINTAIN THE FIRE RATED INTEGRITY. REFER TO DIVISION 7 FOR SPECIAL SEALERS AND MATERIALS. REFER TO BUILDING CODE SUMMARY AND LIFE SAFETY PLANS ON ARCHITECTURAL DRAWINGS FOR FIRE RATED ASSEMBLIES. D. PROVIDE A CLEANOUT AT THE BASE OF ALL SANITARY SOIL OR WASTE STACKS AND STORM RISERS. E. INSTALL PIPING AS HIGH AS POSSIBLE. F. REFER TO FOOD SERVICE DRAWINGS FOR ADDITIONAL REQUIREMENTS. G. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. H. ALL PIPING AND MATERIALS INSTALLED ABOVE THE FIRST FLOOR AND SECOND FLOOR CEILINGS SHALL BE PLENUM RATED OR BE WRAPPED WITH A HIGH TEMPERATURE INSULATION BLANKET OR WRAP MEETING THE FLAME SPREAD AND SMOKE DEVELOPED RATING OF THE BUILDING CODE. PRODUCT SHALL BE 1/2" THICK FOIL FACED WITH A DENSITY OF 6 PCF. PRODUCT SHALL BE SUITABLE FOR OPERATION AT TEMPERATURES UP TO 2300°F. GENERAL PLUMBING NOTES 26 26 28 28 L L 27 27 HH DWBP-1 DIAPHRAGM TANK 3"FD-2 3"FD-2 4"FD-2 FP-1 JOCKEY PUMP FIRE PUMP CONTROLLER AND TRANSFER SWITCH JOCKEY PUMP CONTROLLER FIRE PUMP 138 WH-1 50 51 45 46 47 48 42 43 40 6" CW3" W 52 40 53 40 1 1/2" G (2 PSI) G (2 PSI) 49 394" CW-HP 4" CW39 41 F FF FWW WCO 3" W W 8 DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc ISSUED FOR CONSTRUCTIONP-401 08/27/18 Plumbing Enlarged Plans 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 781-6200 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/4" = 1'-0" Plumbing Enlarged Plan - Feinstein Club4 N 0 8'4'2' 1/4" = 1'-0" Plumbing Enlarged Plan - Level 2 Lobby Bar2 N 0 8'4'2' 1/4" = 1'-0" Plumbing Enlarged Plan - Level 2 Mechanical Room1 N 0 8'4'2' SHEET KEYNOTES 1 6"ST DOWN. 2 4" VENT FROM BELOW. 3 4" VENT UP, 4" VTR. 4 GAS PRESSURE REGULATOR, 2 PSI TO 11" W.C., 500 MBH. 5 1 1/4"G (10" W.C.) DROP. 6 2"G (2 PSI) FROM BELOW. 7 REFER TO WATER SOFTENER DETAIL ON P-501. 8 REFER TO DOMESTIC WATER HEATER (DWH-3 AND DWH-4) PIPING DETAIL ON P-502. 9 1/2"CW AND 1/2"HW FROM BELOW. 10 1/2"CW & 1/2"HW FROM BELOW, 2"W AND 2"V LOOP DOWN. 11 1/2"HW (140°F) FROM BELOW. 12 1/2"CW FROM BELOW. 13 CONDUIT LINE STUBBED UP FROM BELOW FROM SODA SYSTEM TO SODA GUN. 14 CONDUIT LINE STUBBED UP FROM BELOW FROM BEER DISPENSER SYSTEM TO DRAFT BEER TEE TOWER. 15 3" WASTE WITH DEEP SEAL P-TRAP TO FLOOR SINK. 16 2" WASTE AND 2" VENT UP. 17 1/2"CW AND 1/2"HW UP. 18 1/2"HW(140°F) UP. 19 3/4" GAS (7" W.C.) UP. 20 ROUTE INDIRECT WASTE LINES BEHIND EQUIPMENT TO THE FLOOR SINKS. 21 4"ST UP TO 4" ROOF DRAIN (RD-1) AND 4" OVERFLOW DRAIN (OFD-1). 22 4"ST UP. 23 4"ST DOWN. 24 3"ST UP. 25 4"ST DOWN. 26 4"ST UP AND 4"ST DOWN. 27 1 1/2"CW DROP TO FULL SIZE CW SUPPLY HEADER. 28 2"W DOWN, 1 1/2"V RISE, 3/4"CW DROP. 29 2"W DOWN, 1 1/2"V RISE, 1/2"CW & 1/2"HW DROP. 30 1/2"CW & 1/2"HW DROP. 31 4"W DOWN, 2"V RISE. 32 4"W DOWN. 33 2"V FROM BELOW. 34 HWR BALANCING VALVE STATION, SET FOR 1 GPM. 35 3"W DOWN. 36 2"V UP. 37 4"W UP. 38 3/4"CW, 3/4"HW AND 1/2"HW(140°) DROP. ROUTE UNDER COUNTER BEHIND EQUIPMENT. 39 DOMESTIC WATER PRESSURE REDUCING VALVE STATION (DPRV-2). REFER TO DETAIL ON #16/P-501. 40 3"W WITH DEEP SEAL P-TRAP UP TO FLOOR DRAIN. 41 4"W DOWN, 2"V UP. 42 6"ST UP AND DOWN. 43 1 1/2"G (2 PSI) UP. 44 GAS PRESSURE REGULATOR, 2 PSI TO 7" W.C., 145 MBH. 45 6" INCOMING DOMESTIC WATER SERVICE. 46 DOMESTIC WATER METERS, REFER TO DETAIL #13/P-501. 47 DOMESTIC WATER BACKFLOW PREVENTERS (BFP-1 AND BFP-2), REFER TO DETAIL #13/P-501. 48 6"CW RISE. 49 DOMESTIC WATER BOOSTER PUMP (DWBP-1), REFER TO DETAIL #12/P-501. 50 3/4"CW DROP. 51 INCOMING 6" FIRE SERVICE LINE. 52 FIRE PUMP AND FIRE SUPPRESSION PIPING BY FIRE PROTECTION CONTRACTOR. 53 FIRE PUMP TEST HEADER. 54 2"W UP TO LAVATORY. 55 2"W WITH P-TRAP UP TO FLOOR DRAIN. 56 3"W WITH P-TRAP UP TO MOP BASIN. 57 1/2"CW & 1/2"HW ROUTE TO SINK. 58 1/2"(140°)HW ROUTE TO GLASSWASHER. 59 3/8"CW & 3/8"HW ROUTE TO SINK. 60 1/2"CW ROUTE TO DRIP TROUGH. 61 1/2"CW ROUTE TO SODA GUN. 62 CONDUIT LINE FOR BEER DISPENSER SYSTEM UP. 63 CONDUIT LINE FOR SODA SYSTEM UP. 64 CONDUIT LINE FOR BEER DISPENSER SYSTEM DOWN. 65 CONDUIT LINE FOR SODA SYSTEM DOWN. 67 3/4"CW UP. 68 1/2"CW DROP. 69 1 1/2"V RISE, 2"W ROUTED IN WALL SPACE. 70 2"W ROUTED IN WALL SPACE. 71 CONNECT 2"W TO 2"W DOWN. 72 REMOVE THE FLOOR DRAIN GRATE, FURNISH AND INSTALL A BLANK GAS TIGHT COVER PLATE. 73 2"W DOWN, 1 1/2"V RISE, CAP 1 1/2"W FITTING IN WALL SPACE FOR FUTURE LAVATORY. 1/4" = 1'-0" Plumbing Enlarged Plan - Fire Pump Room 1383 N 0 8'4'2' REVISIONS NO. DATE DESCRIPTION 09/12/2018 ADD #2 09/20/2018 ADD #4 10/02/2018 ADD #5 1 08/27/2018 Issued for Construction 3 12/03/2018 General Revisions 6 03/22/2019 Revision 8 8 12/11/2019 Revision 21