Loading...
HomeMy WebLinkAboutP-413-Plumbing-Enlarged-Guestroom-Plans-Rev.228283030LLKKNN3131RR2929SSQQWC-1GWC-1GL-1GSU-1GTD-1SU-1GTD-1L-1G596831247107681" CW1" HW3/4" CW3/4" HW1/2" CW1/2" HW1/2" HW1/2" CW3/4" CW1/2" HW1/2" CW1/2" CW2" W2" W3" W3" W3" W3" W3" W1 1/2" V1 1/2" V2" WGUESTROOM KINGGUESTROOM JUNIORSUITE W/ ADA COMM.1112131/2" HW1/2" CWADD #226262828LLNNRR2727SSQQWC-1GWC-1GL-1GSU-1GTD-1SU-1GTD-1L-1G596831247107681" CW1" HW3/4" CW3/4" HW3/4" CW1/2" HW1/2" HW1/2" CW1/2" HW1/2" CW1/2" CW3" W3" W3" W3" W2" W2" W2" W3" W1 1/2" V1 1/2" V1/2" CWGUESTROOM KINGGUESTROOM KINGA. REFER TO SHEET M-000 FOR GENERAL PLUMBING SYMBOLS, LEGENDS AND ABBREVIATIONS.B. REFER TO MP SERIES DRAWINGS FOR CONDENSATE DRAIN PIPING WORK.C. FIRE BARRIER PENETRATIONS; WHERE PIPES PASS THROUGH THE FIRE RATED WALLS, PARTITIONS, CEILINGS AND FLOORS, MAINTAIN THE FIRE RATED INTEGRITY. REFER TO DIVISION 7 FOR SPECIAL SEALERS AND MATERIALS. REFER TO BUILDING CODE SUMMARY AND LIFE SAFETY PLANS ON ARCHITECTURAL DRAWINGS FOR FIRE RATED ASSEMBLIES.D. PROVIDE A CLEANOUT AT THE BASE OF ALL SANITARY SOIL OR WASTE STACKS AND STORM RISERS.E. INSTALL PIPING AS HIGH AS POSSIBLE.F. REFER TO FOOD SERVICE DRAWINGS FOR ADDITIONAL REQUIREMENTS.G. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR.H. ALL PIPING AND MATERIALS INSTALLED ABOVE THE FIRST FLOOR AND SECOND FLOOR CEILINGS SHALL BE PLENUM RATED OR BE WRAPPED WITH A HIGH TEMPERATURE INSULATION BLANKET OR WRAP MEETING THE FLAME SPREAD AND SMOKE DEVELOPED RATING OF THE BUILDING CODE. PRODUCT SHALL BE 1/2" THICK FOIL FACED WITH A DENSITY OF 6 PCF. PRODUCT SHALL BE SUITABLE FOR OPERATION AT TEMPERATURES UP TO 2300°F.GENERAL PLUMBING NOTESNOTE:REFER TO INTERIOR DESIGN DRAWING PACKAGE FOR GUEST AREA PLUMBING FIXTURE MOUNTING LOCATIONS AND ELEVATIONS.DRAWING NO.DATECDG PROJECT NO.DRAWING TITLE3555 NW 58TH StreetSuite 700-WOklahoma City, OK 73112T: 405.848.9549F: 405.848.9783www.gsb-inc.comCopyright ©GSB, Inc ISSUED FOR CONSTRUCTIONP-41308/27/18Plumbing Enlarged GuestroomPlans17089CARMEL, INCARMEL, IN2018ARCHITECTGSB, INC3555 NW 58th Street, Suite 700WOklahoma City, OK 73112405 / 848-9549CIVIL ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 706-2075STRUCTURAL ENGINEERStructurePoint7260 Shadeland StationIndianapolis, IN 46256317 / 547-5580MEP ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 781-6200INTERIOR DESIGNERHBA Hirsch Bedner Associates171 17th Street NW, Suite 600Atlanta, GA 30363404 / 873-4379FOOD SERVICE CONSULTANTRicca Newmark Design5325 South Valentia WayGreenwood Village, CO 80111303 / 928-1333 3/8" = 1'-0"Plumbing Enlarged Plan - Grid 29-S1 3/8" = 1'-0"Plumbing Enlarged Plan - Grid 27-S206'4'2'06'4'2'SHEET KEYNOTES1 4" WASTE STACK RISER TO BE PROVIDED WITH CLEANOUT ON THIRD ANDFIFTH FLOOR. ACCESS THROUGH ACCESS PANEL IN CABINET.COORDINATE WITH INTERIOR DRAWINGS FOR LOCATION.2 4" VENT STACK.3 COLD WATER RISER.4 HOT WATER RISER.5 1/2"CW & 1/2"HW DROP, 2"W DOWN, 1 1/2"V RISE.6 3"W UP TO WATER CLOSET.7 1/2"CW DROP.8 1/2"CW & 1/2"HW DROP.9 2"W WITH P-TRAP UP TO SHOWER DRAIN, (TD-1).10 1 1/2"V DOWN, 1 1/2"V RISE.11 3" WASTE STACK VENT.12 1/2"CW & 1/2"HW DROP, ROUTE IN WALL TO SINK.13 ROUTE 1 1/2"W IN WALL TO SINK.NO. DATE DESCRIPTION1 08/27/2018 Issued for construction2 09/12/2018 ADD #2ADD #2