Loading...
HomeMy WebLinkAboutP-501-Plumbing-Details-Rev.2BALL VALVEREDUCED PRESSURE BACKFLOWPREVENTER, MAXIMUM MOUNTINGHEIGHT OF 5'-0" ABOVE FLOOR.BALL VALVETO SYSTEMFROM WATERSUPPLY SOURCEAIR GAP DRAIN FUNNELPIPE DISCHARGE TO FLOOR DRAIN OR MOP SINKCONCRETE PADFLOORBRINETANKWATERSOFTENERWATERSOFTENERROUTE BACKWASHDISCHARGE TOFLOOR DRAINFLOOR DRAINHARDWATERINLETSOFTWATEROUTLETNORMALLY CLOSEDFULL LINE SIZEBY PASS LINEMANUAL INLETVALVEMANUAL OUTLETVALVESLOPERISER PIPE SAME AS SEWER18"x18"x4" THICK CONCRETE PADROUND FLANGED HOUSINGW/ HEAVY DUTY CAST IRONCOVER LIKE J.R. SMITH 4251CLEANOUT PLUGFINISH GRADEMIN. 6" PEA GRAVEL OR APPROVEDBACKFILL COMPACTED TO 98%3000 PSI CONCRETE READY MIX12" AROUND BASE OF UNIT TOHEIGHT OF ANTI-BUOYANCY SLABOUTLETINLETEXTENSION COLLARAS REQUIRED24" DIAMETER HEAVY DUTY FRAMEAND COVER FLUSH WITH GRADESECURED IN CONCRETE (H20 RATED)PEA GRAVEL ORAPPROVED BACKFILLCOMPACTED TO 98%OUTLETINLETPEA GRAVEL ORAPPROVED BACKFILLCOMPACTED TO 98%NOTE: INSTALLATIONPER MANUFACTURER'SREQUIREMENTS3" VENT, REFER TOPLUMBING PLANSFOR TERMINATIONMIN. 18"FINISH GRADEREFER TO CIVILDRAWINGS FORINV. EL.REFER TO CIVILDRAWINGS FORINV. EL.GREASE INTERCEPTOR (GI-1)PLAN VIEWREBAR4"MIN. 8"TRAFFIC LOAING PAD REINFORCED CONCRETE RELIEVING PADNOTE: OIL/SAND INTERCEPTOR INSTALLATION SHALL BE PER MANUFACTURER'S, STATE AND LOCAL CODE REQUIREMENTSACCESS LIDTYPICAL REBARCONCRETE PAD MUST EXTEND 18" OUTSIDE OF THE UNIT FOOTPRINTCONCRETE PAD MUST EXTEND 18" OUTSIDE OF THE UNIT FOOTPRINTGREASE INTERCEPTOR SAMPLE BOX, PER CITY OF CARMEL UTILITIES STANDARD DETAIL REQUIREMENTSADD #2MOUNT MOTOR SHAFTIN VERTICAL POSITIONSTRAINERFROM SYSTEMISOLATION VALVE(REFER TO SPECS)SHUTOFF COCK (TYP)PRESSURE GAUGECHECK VALVEUNION (TYP)PUMP AND MOTORTO SYSTEMPIPE HANGER WITHSPRING ISOLATORSCONCENTRIC REDUCER(AS REQUIRED)CONCENTRIC INCREASER(AS REQUIRED)INOUTSLOPESLOPEVENT PIPE TO BE AS HIGH ASPOSSIBLE UNDER COUNTER,THEN DOWN THROUGH FLOORPIPE SLEEVE THROUGHFLOOR, SEE SPECS.VENT UNDER FLOOR,SEE PLAN FORLOCATIONLONG SWEEPSANITARYUNDER FLOORCOMBINATION "Y" AND 1/8BEND LONG TURNFLOORWASTE OUTLETFROM FIXTURECLEAN OUTTHREADEDCLEANOUT PLUGTEST TEEACCESS COVER AND FRAMEFINISHED WALL SURFACECHECK VALVEBALL VALVEFLOWFLOWBALL VALVEFLOW CONTROL VALVETYPICAL PACKAGEDROOFTOP UNITPLUGVALVEUNIONPIPEREDUCERPRESSUREREDUCINGVALVEDIRTLEGPIPING BRANCHREFER TO PLANSFOR SIZEPIPE SUPPORT(TYPICAL)INSTALL GROMMETAT PENETRATION THRUCABINET18" MIN.OR CUSHION STRIPNEOPRENE ISOLATORTHREADED STEEL HANGER RODSYSTEM PIPE (REFER TODRAWINGS FOR TYPE OFSTRUT PIPE CLAMPUNI-STRUT TRAPEZE SUPPORTINSULATIONPIPE INSULATION MATERIAL(REFER TO SPECIFICATIONS)STEEL ROD COUPLINGSYSTEM AND PIPE SIZE)BLOCKING12"PENETRATION BOOT & FLASHING TOMEMBRANE ROOFING BY ROOFINGCONTRACTOR. REFER TO MANUFACTURER'SRECOMMENDATIONS FOR INSTALLATION.PROVIDE STAINLESS STEELCLAMPING BANDSURE SEAL WATER CUT-OFF MASTICROOF DECK - SEE ARCHITECTURALDRAWINGS FOR CONSTRUCTIONOPENING IN DECK BY PLUMBINGCONTRACTORSEE DRAWINGS FOR SIZEINCREASER AS REQUIREDPIPE SIZE PER DRAWINGSCONTROL PANELAND VFD'SHYDROPNEUMATIC TANKTYPICALPUMPTYPICAL FLEXIBLECONNECTORFLOORCONCRETE HOUSEKEEPING PADNORMALLY OPEN FULLLINE SIZE BY-PASSSHUT-OFF VALVEAND CHECK VALVETYPICAL SHUT OFF VALVETYPICAL CHECK VALVECW TOBUILDINGSERVICECW FROM BFP'S, ANDWATER METERSMAXIMUM MOUNTINGHEIGHT OF 5'-0"ABOVE FLOOR.BFP-1METERBFP-2METERREDUCED PRESSURE ZONETYPE BACKFLOW PREVENTER6"CW TO BUILDINGSERVICE DOMESTIC WATER BOOSTER PUMPPROVIDE (2) 2" WATER METERSNEEDLE VALVEPRESSURE GAUGEFINISHED FLOORSEE SPECIFICATIONS FOR PIPESUPPORT REQUIREMENTSTYPICAL DRAIN FUNNEL WITH AIRGAP, TERMINATE DRAIN LINE OVERNEAREST FLOOR DRAIN6"CW INCOMING SERVICEFLOOR SLEEVECOUPLING ADAPTOR (TYP)GATE VALVE (TYP)1. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH UTILITY COMPANY'SREQUIREMENTS. WATER METER FURNISHED BY LOCAL UTILITY, CONTRACTOR INSTALLED.NOTE:4"CWSINKSHUT-OFF VALVE5/8" DRAINHOSE1 1/2" VENT2" SANDISHWASHER3/8" HWCW SUPPLYCOUNTERTOPINSTALL AS HIGH ASPOSSIBLE UNDERTHE COUNTERTOPP-TRAPHW SUPPLYFLOWGAS COCKCONCENTRIC FITTING(TYPICAL)UNION (TYPICAL)FULL SIZED VENT PIPE TO ATMOSPHERE THRU ROOF. DO NOT CONNECT ANY OTHER LINE TO THIS VENTINCREASER/REDUCER (TYP)PRESSURE REDUCING VALVE LOW FLOWPRESSURE GAUGE (TYP)SHUT-OFF VALVE (TYP)PRESSURE REDUCING VALVE HIGH FLOWSTRAINER (TYP)DIVERTER VALVE1/2"CW1/2"HWSHOWER CONTROL VALVE1/2"HAND HELD SHOWERSHOWER HEADNOTE: REFER TO INTERIOR DESIGN GUEST PACKAGE DRAWINGS FOR LOCATIONS, ELEVATIONS AND SPECIFICATIONSDRAWING NO.DATECDG PROJECT NO.DRAWING TITLE3555 NW 58TH StreetSuite 700-WOklahoma City, OK 73112T: 405.848.9549F: 405.848.9783www.gsb-inc.comCopyright ©GSB, Inc ISSUED FOR CONSTRUCTIONP-50108/27/18Plumbing Details17089CARMEL, INCARMEL, IN2018ARCHITECTGSB, INC3555 NW 58th Street, Suite 700WOklahoma City, OK 73112405 / 848-9549CIVIL ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 706-2075STRUCTURAL ENGINEERStructurePoint7260 Shadeland StationIndianapolis, IN 46256317 / 547-5580MEP ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 781-6200INTERIOR DESIGNERHBA Hirsch Bedner Associates171 17th Street NW, Suite 600Atlanta, GA 30363404 / 873-4379FOOD SERVICE CONSULTANTRicca Newmark Design5325 South Valentia WayGreenwood Village, CO 80111303 / 928-1333NOT TO SCALEBackflow Preventer Detail1NOT TO SCALEDuplex Water Softener Piping Detail2NOT TO SCALEExterior Cleanout Detail3NOT TO SCALEGrease Interceptor Detail - Fiberglass4NOT TO SCALEInline Pump Piping Detail5NOT TO SCALELoop Vent Piping Detail6NOT TO SCALENo-Hub Cleanout w/ Access Door Detail7NOT TO SCALEPotable HWR Balancing Station Detail8NOT TO SCALERooftop Unit Gas Piping Detail9NOT TO SCALETrapeze Detail10NOT TO SCALEVent Thru Roof Detail11NOT TO SCALEWater Booster Pump Piping Detail12NOT TO SCALEWater Meter and Backflow Preventer Piping Detail13NOT TO SCALEDishwasher/Sink Detail14NOT TO SCALEGas Pressure Reducing Station Detail15NOT TO SCALEDomestic Water Pressure Reducing Valve Station Detail16NO. DATE DESCRIPTION1 08/27/2018 Issued for construction2 09/12/2018 ADD #2NOT TO SCALETypical Guestroom Shower CW & HW Piping Detail17