P-601-Plumbing-Schedules-Rev.4
GAS WATER HEATER SCHEDULESPECIFICATION SECTION 223400MARKLOCATIONFUEL TYPEHEATING CAPACITYSTORAGECAPACITY(GAL.)EFF %UNITWEIGHT(LBS.)MANUFACTURERWITH MODELNUMBERNOTESINPUTCAPACITY (BTUH)MINIMUMEFFICIENCYRECOVERYGPHRISE °FNOTES:1. 120 VOLT, SINGLE PHASE.2. PROVIDED WITH CONDENSATE NEUTRALIZATION KIT.3. PROVIDED WITH INLINE CIRCULATOR, 1 HP, 115 VOLT, SINGLE PHASE.4. PROVIDED WITH INLINE CIRCULATOR, 3/4 HP, 115 VOLT, SINGLE PHASE.WATER HAMMER ARRESTOR SCHEDULETYPEFIXTURE UNIT RATINGI.P.S.ZURN NUMBERNOTESWHA-A1-113/4"1260XL-A1, 2WHA-B12-321"1260XL-B1, 2WHA-C33-601"1260XL-C1, 2WHA-D61-1131"1260XL-D1, 2WHA-E114-1541"1260XL-E1, 2WHA-F155-3301"1260XL-F1, 2NOTES:1.WATER HAMMER ARRESTORS SHALL BE SIZED AND INSTALLED PER THE PLUMBING DRAINAGEINSTITUTE (STANDARD PDI-WH 201) REQUIREMENTS IN ACCESSIBLE LOCATIONS ON THE COLD WATERAND HOT WATER PIPING WHERE FLUSH VALVES AND ANY OTHER QUICK CLOSING VALVES ARE USED.ROOF/OVERFLOW DRAIN SCHEDULEMARKDESCRIPTIONDRAIN BODYSTRAINERMANUFACTURER WITHMODEL NUMBERNOTESMATERIALOUTLET SIZEOUTLETTYPEMATERIALSIZETYPENOTES:1. PROVIDE WITH SUMP RECEIVER AND UNDER DECK DAM.2. CAST IRON DOME.3. PROVIDE WITH 2" EXTERIOR WATER DAM.4. PROVIDE WITH A THREADED TO NO-HUB FITTING ADAPTOR.WATER SOFTENER SCHEDULEMARKLOCATIONMAXIMUM CAPACITYMINIMUM CAPACITYSERVICE FLOW RATESBACKWASHFLOWRATE (GPM) EACHRESIN(CU.FT.) EACHSALTSTORAGECAPACITY(LBS.)MANUFACTURER WITHMODEL NUMBERNOTESGRAINSCAPACITY EACHSALTDOSAGE(LBS.) EACHGRAINSCAPACITY EACHSALTDOSAGE(LBS.) EACHCONTINUOUSGPM @ 15 PSI DROP EACHPEAK GPM @ 25 PSI DROP EACHNOTES:1. 120 VOLTS AC - 60 Hz - 1 PHASE, LESS THAN 1 FULL LOAD AMPSDIGITAL THERMOSTATIC MIXING VALVE SCHEDULEMARKLOCATIONCAPACITYPRESSUREDROP ATMAX FLOW(PSI)CONNECTION SIZESEXTERIOR FINISHSTRAINERSPRING CHECK VALVESHUTOFFVALVESTHERMOMETERPRESSURE GAUGEMANUFACTURER WITH MODEL NUMBERNOTESMAXFLOW(GPM)MINFLOW(GPM)HWINLET(IN)CWINLET(IN)TEMPEROUTLET(IN)NOTES:1. 115 VOLT, SINGLE PHASE.2. PRE-PIPED, ASSEMBLED, TESTED AND MOUNTED ON ENAMELED STEEL FRAMEDWH-1MECH 702NATURAL GAS1,500,00090%1,745100-1,185LOCHINVAR AWH1500NPM1, 2, 3DWH-2MECH 702NATURAL GAS1,500,00090%1,745100-1,185LOCHINVAR AWH1500NPM1, 2, 3DWH-3MECH 248NATURAL GAS500,00096%582100-339LOCHINVAR AWN501PM1, 2, 4DWH-4MECH 248NATURAL GAS500,00096%582100-339LOCHINVAR AWN501PM1, 2, 4FLOOR DRAIN SCHEDULEMATERIALOUTLETSIZEOUTLETTYPEMATERIALSIZETYPENOTES:1. PROVIDE DEEP SEAL P-TRAP.2. PROVIDE AND INSTALL DRAIN WITH 'SURE-SEAL', 'TRAP-GUARD', 'QUAD-CLOSE' OR SIMILAR SEWER GAS BACK-UP PROTECTION.3. PROVIDED WITH FLASHING FLANGE.4. PROVIDE WITH NICKEL BRONZE RIM AND HINGED GRATE.5. ACID RESISTING COATED RECEPTOR.6. SQUARE TOP DECK DRAIN WITH STATIC EXTENSION, HEEL PROOF GRATE AND ROTATABLE FRAME. REFER TO DRAWING A2-07.7. SQUARE TOP DECK DRAIN, HEAL PROOF DECORATIVE GRATE AND ROTATABLE FRAME.8. WALL TO WALL LINEAR DRAIN ASSEMBLY TO BE COMPATABLE WITH THE SHOWER WATERPROOFING SYSTEM. EQUAL TO SCHLUTER KERDI-LINE LINEAR DRAIN WITH PERFORATED GRATE OR QUICKDRAIN USA SHOWER LINE DRAIN WITH LINES GRATE.SPECIFICATION SECTION 221316MARKDESCRIPTIONDRAIN BODYSTRAINERINTEGRALTRAPVANDELPROOFSEDIMENTBUCKETFUNNELINTEGRALCLEANOUTMANUFACTURER WITHMODEL NUMBERNOTESFD-1FLOOR DRAINCAST IRONAS NOTEDNO HUBNICKEL BRONZE6"SQUARENOYESNONONO1, 2, 3J.R. SMITH #2005YB06NBFD-2FLOOR DRAINCAST IRONAS NOTEDNO HUBAS REQ'DROUNDNONONONOYES1, 2, 3J.R. SMITH #2110YBACKFLOW PREVENTER SCHEDULEPLUMBING EQUIPMENT SCHEDULEMARKMAKE AND MODEL NO.DESCRIPTIONCAPACITYELECTRICALCHARACTERISTICSNOTESNOTES:1. PROVIDE SHUT-OFF VALVES ON INLET AND OUTLET OF EACH TANK. INSTALL FLEX CONNECTORS PROVIDE WITH EACH TANK ON INLET AND OUTLET OF EACH TANK. INSTALL VACUUM BREAKER AFTER FLEX CONNECTOR ON OUTLET SIDE AND BEFORE SHUT-OFF VALVE OF EACH TANK.2. ASME CONSTRUCTED.DHWST-1DOMESTIC HOT WATER STORAGE TANK432 GALLONS-SUCT.(IN)DISCH(IN)HP(WATTS)RPMVOLTSPHNOTES1. SKID MOUNTED TRIPLEX DOMESTIC WATER BOOSTER PACKAGE WITH 50%, 50%, 20% PUMP CAPACITY. PRIMARY PUMPS TO BE GRUNDFOS CRE 20-5 RATED FOR 112 GPM @ 94 PSI BOOST EACH. PILOT PUMP TO BE GRUNDFOS CRE 10-6 RATED FOR 45 GPM @ 94 PSI BOOST. PUMPS TO INCLUDE INTEGRATED VFD PERMANENT MAGNET MOTORS, PROGRAMMABLE CONTROLS, MINIMUM SUCTION PRESSURE OF 33 PSI. OVERALL SYSTEM PRESSURE BOOST OF 94 PSI WITH A SUPPLY FLOW RATE FROM 0 TO 225 GPM. VERTICAL MULTI-STAGE PUMPS. 4" STAINLESS STEEL SUCTION AND DISCHARGE MANIFOLDS WITH 150# ANSI FLANGED CONNECTIONS. 34 GALLON AMTROL ST-60V HYDRO-PNEUMATIC TANK.2. IAC 8-10-3 TITLE 327 INDIANA DEPARTMENT OF ENVIROMENTAL MANAGEMENT; EFFECTIVE JULY 19, 1985. EACH PUMP SHALL BE PROVIDED WITH CONTROLS TO PREVENT THE OPERATION OF PRESSURE BOOSTER PUMPS WHENTHE PUMP SUCTION PRESSURE DROPS BELOW 20 PSIG.3. LEAD-FREE IN ACCORDANCE WITH STATE AND FEDERAL REGULATIONS.4. PARALLEL PUMPS ALTERNATE IN OPERATION.MARKLOCATIONSYSTEMTYPEDESIGNCAPACITY(GPM)DESIGNCAPACITY(FT. HD)MINEFF.PUMPMOTOR DATAMANUFACTURER WITHMODEL NUMBERNOTESPUMP SCHEDULEDWBP-1FIRE PUMP 138DOMESTIC WATERTRIPLEX DOMESTIC WATERBOOSTER PUMP PACKAGE22521872.2441536004603GRUNDFOS MPC-E 3/2CRE 20-5, 15 HP, 3x460V1, 2, 3NOTES:1. USC APPROVED, FDA EPOXY COATED STRAINER, 7.5 FPS FLOW.2. IN-LINE, INDEPENDENT CHECK VALVES WITH AN INTERMEDIATE RELIEF VALVE, NON-RISING STEM RESILIENT SEATED GATE VALVES.3. PROVIDE UNIT WITH AIR GAP DRAIN ASSEMBLY, PIPE DRAIN TO NEAREST FLOOR DRAIN OR SINK.4. MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR.5. IN-LINE INDEPENDENT CHECK VALVES WITH INTERMEDIATE RELIEF VALVE, FULL PORT QUARTER-TURN RESILIENT SEATED BALL VALVE.6. LEAD FREE.MARKLOCATIONSYSTEMTYPEDESIGNCAPACITY(GPM)PRESS.DROP(PSIG)SIZE(IN)MANUFACTURER WITHMODEL NUMBERNOTESBFP-1WATER METER RMMAIN CW SYSTEMREDUCED PRESSUREZONE ASSEMBLY175143WATTS LF909WATTS LF9091, 2, 3, 4, 6BFP-2MAIN CW SYSTEMREDUCED PRESSUREZONE ASSEMBLY175143WATTS LF909WATTS LF9091, 2, 3, 4, 6WATER METER RMDHWST-2DOMESTIC HOT WATER STORAGE TANK432 GALLONS-DHWST-3DOMESTIC HOT WATER STORAGE TANK250 GALLONS-DHWST-4DOMESTIC HOT WATER STORAGE TANK250 GALLONS-WS-1MECH 248150,00015 125,00010 53697.55800AQUA SYSTEMS MODEL 500 DUPLEX TANK WITH PROGRESSIVE FLOW1DTMV-1MECH 7021158222HWR TO HEATER (IN)1HWR RETURN INLET (IN)1 1/2YESYESYESYESYESARMSTRONG THE BRAIN WITH BRAIN SCAN MODEL DMC501, 2DTMV-2MECH 2484851 1/21 1/21 1/211YESYESYESYESYESARMSTRONG THE BRAIN WITH BRAIN SCAN MODEL DMC401, 2BFP-3BOILER MAKE UP20101WATTS LF009M2QT3, 4, 5, 6MECH 702REDUCED PRESSUREZONE ASSEMBLYNICKEL BRONZEFS-1FLOOR SINKCAST IRONAS NOTEDNO HUBNICKEL BRONZEAS REQ'DSQUARENONONONOYES1, 2, 3, 5J.R. SMITH #3161-12FS-2FLOOR SINKCAST IRONAS NOTEDNO HUBAS REQ'DSQUARENONONONOYES1, 2, 3, 4, 5J.R. SMITH #3161-19NICKEL BRONZERD-1ROOF DRAINCAST IRONAS NOTEDNO-HUBCAST IRON DOMEAS REQ.ROUNDJ.R. SMITH #1010Y1, 2OFD-1OVERFLOW DRAINCAST IRONAS NOTEDNO-HUBCAST IRON DOMEAS REQ.ROUNDJ.R. SMITH #1080Y1, 2RD-2ROOF DRAINCAST IRONAS NOTEDNO-HUBCAST IRON DOMEAS REQ.ROUNDJ.R. SMITH #1320T-R-C-CID1, 2, 4OFD-2OVERFLOW DRAINCAST IRONAS NOTEDNO-HUBCAST IRON DOMEAS REQ.ROUNDJ.R. SMITH #1320T-WD-R-C-CID1, 2, 3, 4DS-1DOWNSPOUT NOZZLECAST BRONZEAS NOTEDNO-HUBN/AN/AN/AJ.R. SMITH #1771-2.CERTIFIED TO NSF/ANSI 372 BY IAPMO.MECH 702MECH 702MECH 248MECH 248LOCATIONLOCHINVAR RGA0432LOCHINVAR RGA0432LOCHINVAR RGA0257LOCHINVAR RGA0257DET-1THERMAL EXPANSION TANK53 GALLON TANK VOLUME, .66 MAX. ACCEPT. FACTOR-DET-2THERMAL EXPANSION TANK-MECH 702MECH 248AMTROL ST-80VCAMTROL ST-60VC2225 GALLON TANK VOLUME, .44 MAX. ACCEPT. FACTORASU-1ANTI-SCALE UNIT FOR DOMESTIC COLD WATER75 GPM MAX. FLOW RATE, 10 PSI PRESSURE DROP-ASU-2MECH 702MECH 702WATTS ONEFLOW #OF1665-75TM1ANTI-SCALE UNIT FOR DOMESTIC HOT WATER12 GPM MAX. FLOW RATE, 10 PSI PRESSURE DROP-WATTS ONEFLOW #OF817-12H1GI-1EXTERIORGREASE INTERCEPTOR2000 GALLON TOTAL WET VOLUME1159 GALLON GREASE CAPACITY589 GALLON SOLIDS CAPACITY-PRECEPTOR #GMC2000UPC-AD-1AD-2FD-3FLOOR/SHOWER DRAINCAST IRONAS NOTEDNO HUB6"SQUARENONONONONO1, 2, 3ZURN #ZS415-2-NH-6-SZ1POLISHED STAINLESS STEELTD-1DWRP-1DWRP-2MECHANICAL 702DOMESTIC HOT WATER RETURNVERTICAL MULTISTAGE CENTRIFUGAL2071-1 1/41 1/41360-40002081GRUNDFOS CRE 3-5A-FGJ-A-E-HQQE3, 4DWRP-3DWRP-4MECHANICALDOMESTIC HOT WATER RETURNWET ROTOR IN-LINE826---(285)-1151GRUNDFOS MANGNA3 40-80F N3, 4DWRP-5DWRP-6MECHANICALDOMESTIC HOT WATER RETURNWET ROTOR IN-LINE534---(448)-1151GRUNDFOS MAGNA 3-10-120F N3, 4LOW FLOWHIGH FLOWNOTES1. CLA-VAL 90-01 SERIES.STATION MARKLOCATIONSYSTEMCLASS RATINGFLOW RATE GPMNOTESDOMESTIC WATER PRESSURE REDUCING VALVE STATION SCHEDULEDPRV-1MECHANICAL 702COLD WATER15045901PRESSURE IN (PSI)80PRESSURE OUT (PSI)59TOTAL135DPRV-2FIRE PUMP 138COLD WATER1504897112570145AREA DECK DRAINCAST IRONAS NOTEDNO HUB10"SQUARENOYESNONOYES7ZURN Z158-DTNICKEL BRONZEAREA DECK DRAINCAST IRONAS NOTEDNO HUB10"SQUARENOYESNONOYES6ZURN Z158-85-DTNICKEL BRONZETRENCH DRAINSTAINLESS STEELAS NOTEDNO HUBAS REQ'DLINEARNONONONONO8-STAINLESS STEELBFP-4IRRIGATION20101WATTS LF009M2QT3, 4, 5, 6JAN 158REDUCED PRESSUREZONE ASSEMBLY5DRAWING NO.DATECDG PROJECT NO.DRAWING TITLE3555 NW 58TH StreetSuite 700-WOklahoma City, OK 73112T: 405.848.9549F: 405.848.9783www.gsb-inc.comCopyright ©GSB, Inc ISSUED FOR CONSTRUCTIONP-60108/27/18Plumbing Schedules17089CARMEL, INCARMEL, IN2018ARCHITECTGSB, INC3555 NW 58th Street, Suite 700WOklahoma City, OK 73112405 / 848-9549CIVIL ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 706-2075STRUCTURAL ENGINEERStructurePoint7260 Shadeland StationIndianapolis, IN 46256317 / 547-5580MEP ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 781-6200INTERIOR DESIGNERHBA Hirsch Bedner Associates171 17th Street NW, Suite 600Atlanta, GA 30363404 / 873-4379FOOD SERVICE CONSULTANTRicca Newmark Design5325 South Valentia WayGreenwood Village, CO 80111303 / 928-1333REVISIONSNO. DATE DESCRIPTION09/12/2018 ADD #209/20/2018 ADD #41 08/27/2018 Issued for Construction5 02/22/2019 RFI-43