ELECTRICAL ABBREVIATIONS
A
AFF
co
CONTR
DN
DWG(S)
EC
EDC
EM
WUIP
ETR
EWC
EX
FLA
FS
GC
HP
MAX
MB
MC
MCA
MFR
MH
MIN
MLO
MOCP
MOD
MTD
NIC
NTS
OC
PC
P51
RLA
RPM
V
UON
AMPS
ABOVE FINISHED FLOOR
COMPANV
CONTRACTOR
DOWN
DRAWIN6(S)
ELECTRIC CONTRACTOR
ELECTRICAL DISTRIBUTION CEMER
EMERGENCV
E�UIPMENT
EXISTING TO REMAIN
ELECTRIC WATER COOLER
EXISTING
FULL LOAD AMPS
FLOW SWITCH
GENERALCONTRACTOR
HORSEPOWER
MAXIMUM
MAIN BREAKER
MECHANICALCONTRACTOR
MIMIMUM CIRCUIT AMPS
MANl1FACTURER
MOl1NTING HEIGHT
MINIMUM
MAIN LUG ONLV
MAXIMUM OVER CURRENT PROTECTION
MOTOROPERATEDDAMPER
MOUNTED
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
PLUMBING CONTRACTOR
POUNDSPERSpUAREINCH
RUNNING LOAD AMPS
REVOLUTIONS PER MINUTE
VOLTS
UNLESS OTHERWISE NOTED
PANELBOARD SCHEDULE
ABBREVIATIONS
L LIGHTING
R RECEPTAQE
PN POWERNONSEASONAL
PW POWERWINTER
MN MOTORNONSEASONAL
MNI MOTOR NON-SEASONAL INTERMITTENT
MS MOTORSUMMER
MW MOTOR WINTER
KT KITCHEN
��x�1:7[HG1�.9'IJiI Z�l�.y
DISCONNECT ��
EXIT SIGNAGE e
EXIT SIGNAGE WITH EMERGENCV HEADS `-µ-'
EMERGENCV LIGHTMG UNIT - -
EMERGENCV EXR EGRESS LIGHT �
SUSPENDED STRIP LIGHT
SURFACE MOUNTED STRIP LIGHT
RECESSE� �OWN LIGHT
MOTOR
LIGHT FIXTURE - ON NIGHT LIGHT CIRCUIT
�
`
�
�
LAVIN TROFFER FIXTURE
�
SUSPENDED LAVIN
SURFACE MOUNTED LAVIN
�
LIGHTFIXTURE-UNDERCOUNTER I
LIGHT FIXTURE- WALL SCONCE I__ ,
LIGHT RXTURE - PEN DANT
LIGHTFIXTURE-TRACK � � � F
LIGHT RXTURE - RECESSED DOW N LIGHT
LIGHTFIXTURE-VANITVLIGHT �(�'�,
OURET - 4 WAV #
OURET - DUPLEX 'II�
OURET-GROUNDFAULTINTERRUPT ('
OURET-GROUNDFAULTINTERRUPTWEATHERPROOF �Wp
OURET - DUPLEX WITH U5B ¶��
OUTLET-220 ..
JUNCTION BOX IJI �
SPECIAL E�UIPMENT COORDINATE W/SUPPLIER ��1
FLOOROUTLETWITHPOWER,DATAANDPHONE �-Q� RR
LOW VOLTAGE ONE LME l.�
LOW VOLTAGE TWO LME �
LOW VOLTAGE k LINES � p
ANALOG PHONE LINE ,
W IRELESS ACCESS POINT WAP
PUSH BUTTON
BUZZER
PHOTO CELL
POWERPOLE
TIME CLOCK
SWITCH
B�
P
f- PP
n
SWITCH - 3 WAV I'3
SWITCH - 4 WAV �'4
SWITCH WITH DIMMER �p
SWITCHWITHOCCUPANCYSENSOR �OS
CEILING MOUNTED OCCUPANCV SENSOR OSi
PANEL DESIGATION I � CIRCUIT BREAKER NUMBERS
1 1 1 1
X_ XX,XX,XX
DOORALARM CONTROLPANEL DACP
HMGESIDEPLUNGERSWITCH IDCI
MAGNETIC LOCK WITH KEV PAD I KPI
MAGNETIC LOCK WITH CARD READER ICRI
ELECTRICAL SPECIFICATIONS
1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE
BID IN STRICT ACCORDANCE WITH DESIGN BA515
EpUIPMENT AND MATERIALS. PROJECT DOES ENCOURAGE
COMPETITIVE PRICMG AND ALLOWS FOR SUBSTITUTIONS
OF EQUAL EQUIPMENT AND MATERIALSAGAINST THE BASIS
OF DESIGN. SUBSTITUTE ITEMS WILL BE COMPARED
AGAINST DESIGN BASIS DURING SUBMITTAL PROCESS.
ENGINEER RESERVES THE RIGHT TO REJECT
SUBSTITUTIONS FOUND NOT TO BE EpUAL TO ITEMS
LISTED IN DESIGN BASIS..
2. PRIORTOPROCUREMENTCONTRACTORSHALLSUBMITTO
ARCHITECT FULL SUBMITTALS FOR ALL ENERGV
CONSII MMG OR PRODl1CMG ITEMS AND FOR ALL SW ITCH
GEAR, LOAD CENTERS AND PANEL BOARDS. SUBMITTALS
SHALL BE DELMEATED WITH TAGS INDICATED ON PRINTS
CONTRACTORS NAME AND PROJECT NAME CLEARLV
INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES
AND OPTIONS BEMG PROVIDED. Sl1BMISSIONS SHALL BE IN
PDF FORMAT. ALL E�UIPMENTAND ITEMS SHALL BE PER
DESIGN BASIS ORAPPROVED EQUAL. ENGINEER RESERVES
THE RIGHT TO REJECT ANV SUBSTITUTE ITEM FOUND NOT
EpUAL TO THE SPECIFIED ITEM AS DESIGNED.
3. CONTRACTOR SHALL FURNISH ATEMPORARV SERVICE FOR
THE USE OF ALL TRADES DURMG CONSTRUCTION AS
REQUIREDBVTHEGENERALCONTRACTOR. REMOVEALL
TEMPORARY EpUIPMENT AS PERMANENT SERVICES
BECOME AVAILABLE.
4. THE DRAWMGS IN THIS SECTION ARE DIAGRAMMATIC AND
ARE NOT IMENDED TO DERNE EXACT �UANTITIES,
LOCATIONSORCODIFIEDREpUIREMENTS. DRAWINGS
SHOW GENERAL INTENT OF SVSTEMS. MODIFICATIONS IN
ELECTRICAL SVSTEM ROUTMG AND LOCATIONS AS
RE�UIRED TO MEET THE INTENT, SHALL BE PERFORMED
WITHOUT ADDITIONAL COST TOOWNER. SECURE AND PAV
FORALL REpUIRED PERMITS.
5. THEELECTRICALCONTRACTORISTOPROVIDEALL
REpUIRED LABOR, MATERIALS, EQ W PMENT, AND
CONTRACTOR'S SERVICESNECESSARYTOCOMPLETETHE
INSTALLATION OF SVSTEMS RE�UIRED M FULL
CONFORMITV WITH APPLICABLE CODES AND ORDINANCES.
THE FlN ISHED JOB SHALL BE FUNCTIONAL AND COMPLETE
IN EVERV DETAIL INC W DMG ANV AND ALL Sl1CH ITEMS FOR
A COMPLETE SYSTEM. CONTRACTOR SHALL GUARANTEE
ALL LABOR AND MATERIALS ENTERING INTO CONTRACT
FOR A PERIOD OF ONE (1) VEAR FROM DATE OF
ACCEPTANCE.
6. ALL WORK SHALL IN BE IN Fl1LL ACCORDANCE WITH 2O09
INDIANA ELECTRICAL CODE (2008 NFPA ]0), 2010 INDIANA
ENERGV CODE (ASHRAE 90.1-2001), PERTMENT STATE,
COUNTV, CODES AN D ORDINANCE AND INDIANA
AMENDMENTS. COORDINATE WORK WITH OTHER TRADES.
ELECTRICAL CONTRACTOR SHALL BEAR ALL COSTS
RESULTMG FROM ANY NON COMPLIANCE WITH CODE
REQUIREMENTS.
]. MATERIALSANDEpUIPMENTSHALLBENEWUNLE55
INDICATED OTHERWISE. MATERIAL SHALL BEAR U.L. LABEL
WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED AND
LISTED BV U.L. MATERIALS AND WUIPMENT SHALL
CONFORM WITH THE LATEST ISSUESOF APPLICABLE
TECHNICAL STANDARDS.
8. THEELECTRICALCONTRACTORISTOPROVIDEA
COMPLETE SYSTEM OF LIGHTMG, RECEPTACLES, AND
POWERASRE�UIRED. VERIFVALLVOLTAGESANDPHASE
REpUIREMENTS WITH MECHANICAL CONTRACTOR'S
EpUIPMENT PRIOR TO PERFORMING ANV WORK.
9. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND
VERIFV ALL EXISTWG CONDITIONS BEFORE SUBMITTMG A
BID. NO EXTRAS W ILL BE ENTERTAINED FOR
CONTRACTORS FAILURE TO IDENTIFY EXISTING
CONDITIONS AND ADJUST AS REpU IRED TO MEET DESIGN
INTENT.
10. ALLCONDUITCOUPLWGSANDCONNECTIONSSHALLBE
COMPRESSION TVPE AND MADE TO ENSURE POSITIVE
GROUNDMGCONTINUITV. MAKECONNECTIONSTO
EpUIPMENT SUBJECT TO VIBRATION WITH 18 MCHES OF
FLEXIBLE WATERTIGHT CONDUIT WITH WATERTIGHT
FITTWGS. PROVIDEFORSUPPORTANDSECURMGOFALL
CONDUIT AND WUIPMENT. CONNECTIONS TO LIGHTMG
FIXTURES SHALL BE MADE WITH SIX (6) FEET OF REXIBLE
CONDUIT FROM A BOX WITHIN TWO (2) FEET OF THE
FIXTl1RE. SPLICE ALL W IRES ONLV IN ACCESSBLE BOXES.
ALL FIXTURE WHIPS TO BE FLEXIBLE METAL CONDUIT 1/Y'
MINIMUM SIZE WITH COMPRESSION CONNECTORS WITH
INSULATEDTHROATS. WHIPSSHALLNOTEXCEED6'.
FIXTURE WHIPS TO BE SUPPORTED FROM BUILDING
STRUCTURE.
11. ALL LIGHTMG AND BRANCH CIRCUIT WIRMG SHALL BE
SOLID COPPER MINIMUM SRE#12AWG.600V INSULATION,
15 DEG. C., TVPE THW OR THWN, NOT LE55 THAN #12 AWG.
ALL WIRE SERVING AS FEEDS TO DISTRIBl1TION PANEL
BOARDS OR INTEGRAL HORSEPOWER MOTORS SHALL BE
EITHER STRANDED COPPER CONDUCTOR OR ASTM B800
ALUMINUM AA-8000 SERIES. THESE SHALL BE SRED NOT
LESS THAN #10 AW G FOR COPPER AND NOT LESS THAN #8
AWG FORAWMINl1M. EACH WITH MINIMUM 600V THW OR
THWN INSl1LATION, ]5 DEG. C. ALL FEEDER SHALL BE
SIZED IN ACCORDANCE W ITH NEC 310.15.
12. EXPOSED WIRING SHALL BE IN EMT RHCEWAV. EXTERIOR
WIRING SHALL BE IN CONDUIT. CONCEALED W IRING SHALL
BE IN EMT OR METAL CLAD CABLE WHERE ALLOWED BV
CODE.
13. ALL LOW VOLTAGE WIRMG IN PLENUM RATED CEILMGS OR
EXPOSED IN ROOMS SHALL BE PLENUM RATED CABLE.
14. ALL CABLE SHALL BE NEW W IRE OF RECENT
ELECTRICAL SPECIFICATIONS
MANUFACTURE AND IN ACCORDANCE WITH THE LATEST
STAN DARDS OF IPCEA AND NEMA AS A MIN IMUM
15. QRCUITBREAKERSSHALLBEpUICK-MAKE,pUICK-BREAK,
THERMAL-MAGNETIC, TRIP INDICATMG AND HAVE COMMON
TRIP ON ALL MULTI-POLE BREAKERS. BRANCH CIRCUIT
BREAKERS FEEDING CONVENIENCE OUTLETS SHALL HAVE
SENSITIVE INSTANTANEOUS TRIP SETTINGS OF NOT MORE
THAN 10 TIMES THE TRIP RATING OF BREAKER TO PREVENT
REPEATED ARCMG SHORTS RESULTMG FROM FRAVED
APPLIANCE CORDS. CONNECTION TO BUS SHALL BE BOLT
ON.
i6. CONTRACTORTOOBTAINMAXIMUMFAULTCURRENT
AVAILABLE FROM THE UTILITV. CALCl1LATE THE FAl1LT
CURRENTAVAILABLEATTHEPANELS. ALL
PANELS/BREAKERS/SW ITCHES ARE TO BE BRACED TO
EXCEED MAXIMUM AVAILABLE FAULT CURRENT AND
QRCUIT BREAKERS ARE TO BE CAPABLE OF INTERRUPTING
FAULT CURRENT. MAN UFACTURER SHALL PROVIDE ALL
REpUIRED FAULT CURRENT AND ARGFLASH LABELMG PER
110.16 AND 11024.
11. MAXIMUMLOADMGOF20AMPCIRCUITSSHALLNOT
EXCEED 1]50 WATTS. VOLTAGE DROP OF BRANCH
CIRCUITS SHALL NOT EXCEED 3% AND FEEDER CIRCUITS
SHALL NOT EXCEED 2%. SEAL ALL PENETRATIONS
THROUGH WALLS, CEILMGSAND FLOORSAIR AND WATER
TIGHT. FIRE STOP WHERE REQUIRED.
18. CONTRACTORSHALLPROVIDEENGRAVEDBAKELITE
NAMEPLATES FOR ALL ELECTRICAL PANELS,
DISCON NECTS, TRANSFORMERS AND MOTORS OVER 1 HP.
FURNISH TVPEWRITTEN PANEL DIRECTORIESTOIDENTIFV
ALL ELECTRICAL CIRCUITS BOTH NEW AND EXISTING.
19. VERIFYEXACTLOCATION,COLORANDHEIGHTSOFALL
Ol1TLETS, RECEPTACLE$ LIGHT FIXTl1RES AN D EQUIPMENT
WITH OWNER'S REPRESENTATIVE PRIOR TO START OF
WORK FURNISH GENERAL SERVICE DUPLEX'S, 15 AMP
SWITCHES, 15/20AMP GFICS, HEAW DUTV DISCONNECTS,
HVAC SSU SWITCHES, PANEL BOARDS, LOAD CENTERS,
DISTRIBUTION PANELS ETC. AS REpUIRED.
20. DISCONNECTSWITCHESSHALLBEGENERALDUTY,NEMA
TVPE 1 FOR INDOOR SERVICEAND NEMATVPE 3R FOR
OUTDOOR SERVICE, SUITABLE FOR PADLOCKING, NUMBER
OF POLES, RATINGS, FUSES QF REpUIRED) SHALL BE AS
INDICATED ON THE DRAWINGS.
21. DEVICES:
A. CONVENIENCERECEPTACLESSHALLBEMOUMEDIB"
ABOVE RNISHED ROOR (AEF.) TO BOTTOM UNLESS
NOTED OTHERWISE, SWITCHES AND PUSHBUTTONS SHALL
BE 4P' A.F F. TO BOTTOM UNLESS SPECIFIED OTHERW ISE
ON THE DRAWINGS.
B. PRIOR TO ROUGH-M EG SHALL VERIFV FINAL LOCATIONS
AND COLORS OF ALL DEVICES WITH OWNER.
C. INSTALL ALL DEVICES PARALLEL AND PERPENDICULAR TO
ADJACENT WALL AND CEILMG, FWSH WITH SURROUNDMG
SURFACES AND FREE FROM ALL OBSTRUCTIONS.
REWORKING OF EpUIPMENT INSTALLED IMPROPERLV
SHALL BE AT THE CONTRACTOR'S EXPENSE.
D. SWITCHES, BOXES, ETC., SHALL BE NEMATVPE 1
CONSTRUCTION FOR INDOOR APPLICATIONSAND NEMA
TVPE 3R CONSTRUCTION FOR OUTDOOR APPLICATIONS.
E SWITCHESSHALLMEETNEMASTANDARDS,COLORSHALL
BE BV ARCHITECT. SWITCHES SHALL BE EpUAL TO
HUBBELL COMMERCIAL SPECIFICATION GRADE 20I15
AMPERES, SMGLE POLE, 125/21N. MULTI-POLE OR
SPECIAL SWITCHING SHALL BEAS NOTED ON THE
DRAWINGS.
F. RECEPTACLESSHALLBE125VOLT,15/20AMPERES,
DUPLEX, GROUNDED HUBBELL COMMERCIAL
SPECIRCATION GRADE SPECIAL RECEPTAQES SHALL BE
AS NOTED ON THE DRAW INGS.
G. MATCHING COVER PLATES SHALL BE PROVIDED FOR ALL
RECEPTACLES AND SW ITCHES.
23. LIGHTMG FIXTURES:
A. CONTRACTORSHALLBERESPONSIBLEFORVERIFVING
FIXTURES- M W EL NUMBERS, QUANTITV AND DISTANCE
BETWEEN LIGHTING FIXTl1RE PER FLOOR PLANS.
B. PRIORTOROUGH-INE.C.SHALLVERIFVFIXTURE
QUANTITV, MODELS, STVLE, TRIM, LENS, ETC- WITH OWNER
FOR ALL FIXTURES.
G PROVIDE LIGHTING FIXTURES COMPLETE WITH, BUT NOT
NECESSARILV LIMITED TO, HOUSINGS, LAMPS, LAMP
HOLDERS, REFLECTORS, BALLASTS, STARTERS AND
WIRING.
24. INSTALLATION OF LIGHTING FIXTURES:
A. INSTALL LIGHTING FlXTURESAT LOCATIONS AND HEIGHTS
AS INDICATED, IN ACCORDANCE WITH FIXTURE
MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE
RE�UIREMENTS OF NEC, NECA'S "STANDARD OF
INSTALLATION", NEMASTANDARDS, AND WITH RECOGNRED
INDUSTRV PRACTICESTO ENSURE THAT LIGHTING
FIXTURES FULRLL REpUIREMENTS.
B. COORDINATE WITH OTHER ELECTRICAL WORK AS
APPROPRIATE TO PROPERLV IMERFACE INSTALLATION OF
INTERIOR LIGHTING FlXTURES WITH OTHER WORK.
C. E.C.TOFASTENFIXTURESSECURELVDIRECTLVTO
BWLDMGSTRUCTURALSVSTEM. LIGHTTROFFERSSHALL
ELECTRICAL SPECIFICATIONS
�
E.
BE SUPPORTED AT EACH CORNER OF RXTURE BV WIRES
OF SAME GAUGE AS HANGER WIRE FOR CEILING GRID.
ATTACH EARTHpUAKE CLIPSTO GRID AS RECOMMENDED
BV LIGHT MANl1FACTURER. 11SE SCREWS IF REpUIRED BV
MANUFACTURER. ATTACH THE WIRE TO THE STRUCTURE
ABOVE. LIGHTSSHALLNOTBESUPPORTEDINANVWAVBV
LAV-IN CEILING.
FIXTURE LOCATIONS SHALL BE AT APPROXIMATE
LOCATIONS AS SHOWN ON THE DRAW WGS FREE FROM ALL
OBSTRUCTIONS. CLEAN ALL LIGHTMG E�UIPMENT AFTER
LIGHTMG INSTALLATION AND GENERAL CONSTRUCTION IS
COMPLETE REPAIRANVFIXTURESDAMAGEDDURING
CONSTRUCTIONS.
PROVIDE NECESSARV MOUNTMG FRAMES, SUPPORTSAND
RELATED ITEMS RE�UIRED TO PROPERLY INSTALL
FIXTURES. SUPPORTFIXTURESINDEPENDENTLVOFPIPING
ANDDUCTWORK. MAKEMODIFlCATIONSTOTHE
STRUCTl1RE AS REQl11RED TO INSTALL FIXTURES. ANV
MODIFICATIONSTOTHE STRUCTURE SHALL NOT IMPAIR
THE STRUCTURAL IMEGRITV OF THE BUILDMG.
26 EpUIPMENTCONNECTIONS
A. ALL DEVICESAND EpUIPMENT SHALL BE SOLIDLV
GROUNDED IN ACCORDANCE WITH NEC REQWREMENTS.
B. ALLSOLIDCONDUCTORWIRESMAYBETERMINATED
UNDER SCREW HEADS. STRANDED WIRES MAV BE
TERMINATED BV USING PUSH-IN CLAMP TVPE
CONNECTORS FURNISHED WITH DEVICES OR TERMINATED
W ITH COMPRESSION TVPE TERMINAL W GS. SET SCREW
TVPE TERMINATIONS ARE NOT PERMITTED.
G NOMOTORSARETOBESUPPLIEDUNDERTHISCONTRACT
UNLESS ITEMS REpUIRING A MOTOR ARE FURNISHED BY
THISCONTRACTOR. THECONTRACTORSHALLFl1RNISH
ALL STARTERS FOR ALL MOTORS REpUIRMG A STARTER.
THE CONTRACTOR SHALL CONNECT ALL POW ER
EQUIPMENT IF & WHERE SHOWN ON PLANS UNLE55
OTHER-WISE SPECIFIED & ASSURE OWNER THE MOTORS
ARE IN GOOD RUNNING ORDER.
D. EG.SHALLPROVIDEALLCOMPONENTSNEEDEDTOMEET
MEANS OF DISCONNECT PER N.EG FOR ALL HARD WIRED
EpUIPMENT.
26. LOW VOLTAGE
A. ALL LOW VOLTAGE CABLE WHERE CONCFALED IN
CONSTRUCTION OR IN EXPOSED OPEN AREAS SHALL BE
FREE RUN. CONTRACTOR SHALL INSTALL 3/4" CONDUIT
(MINIMUM) FROM EACH LOW VOLTAGE ROUGH-IN LOCATION
TOACCESSIBLECEILINGSPACE,LOW VOLTAGEWIRE
TRAV OR HANGERS AND THEN TO MDF, HEAD-IN, PBX
PUNCH DOWN, CONTROLLER ETC.
B. E G SHALL COORDINATE W ITH LOCAL PHONE AND CABLE
PROVIDER AS CHOSEN BY O WN ER AND PROVIDE
RACEWAVS FOR BRWGMG IN SERVICES AS REpUIRED.
C. ALL LOW VOLTAGE CABLE SHALL BE PLENUM RATED IN
PLENUMS.
D. ALL DATA CABLE SHALL BE CAT 6 UNLESS OTHER WISE
NOTED. TERMINATE, LABEL AND TEST ALL WIRING.
E. ALL TV CABLE SHALL BE HIGH DEFINITION COAX RG6 OR AS
REpUIRED BV PROVIDER, VERIFV PRIOR TO ROUGH IN.
21. CLOSE OUT
A. PROVIDEMANUFACTURERSOPERATIONAND
MAINTENANCE MANUALS AND PROVIDE AS BUILT
DRAW W GS. PROVIDE (1) TRAIN W G SESSION TO OWN ER
SELECTED PERSONNEL AS RE�UESTED AND PROVIDE
WARRANTV MFORMATION FORALL MANUFACTURERS
WARRANTEDEpUIPMENT
�
Z
w J �
w
z / '
� � �
z
w � .
� E
W �
Q L U
U u�i �
O C
N � � N
> N
Q W > �
°2% m � N lt� (D �
N
N
r
� C � � 0 � �
�U a�Z�n��
U � � >
�
C � � tp
a
or�r�-o
V
O� anoQ aLL W
OWNER:
RANGELINE CHIROPRACTIC
XXX
CARMEL, IN
CONTRACTOR:
ALT CONSTRUCTION
10650 N BENNET PKWV SURE 200
ZIONSVILLE,IN 460]]
ARCHITECTURE:
ALO PROPERTY GROUP
9015 N MERIDIAN ST, SUITE 115
INDIANAPOLIS, IN 46260
MEP:
DESIGN BUILD
U
�
U
�
�
I
U
W
Z
J
,Wn
V
z
L.1_
Z
O
�
Q
�
O
Z
W
I..V
1..�
0
I..L
W
Z
No.
10200395
,.a.e or
�
� Q
zQ
O �
� �
} J
w w
Y�
N �
N Q
�U
�z-�a-zo�s
ELECTRICAL ABBREVIATIONS,
SYMBOLS, & SPECIFICATIONS
E001