HomeMy WebLinkAboutInverter Data SheetINVERTERSsolaredge.com
Optimized installation with HD-Wave technology
Specifically designed to work with
power optimizers
Built-in module-level monitoring
Outdoor and indoor installation
Optional: Revenue grade data, ANSI C12.20
Class 0.5 (0.5% accuracy)
Record-breaking efficiency
Fixed voltage inverter for longer strings
Integrated arc fault protection and rapid shutdown for
NEC 2014 and 2017, per article 690.11 and 690.12
Extremely small
UL1741 SA certified, for CPUC Rule 21 grid
compliance
Single Phase Inverter
with HD-Wave Technology
for North America
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US /
SE7600H-US / SE10000H-US / SE11400H-US
12-25
YEAR
WARRANTY
02/03/20
David Rutti
SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US
OUTPUT
Rated AC Power Output 3000 3800 @ 240V
3300 @ 208V 5000 6000 @ 240V
5000 @ 208V 7600 10000 11400 @ 240V
10000 @ 208V VA
Maximum AC Power Output 3000 3800 @ 240V
3300 @ 208V 5000 6000 @ 240V
5000 @ 208V 7600 10000 11400 @ 240V
10000 @ 208V VA
AC Output Voltage Min.-Nom.-Max.
(211 - 240 - 264)9 9 9 9 9 9 9 Vac
AC Output Voltage Min.-Nom.-Max.
(183 - 208 - 229)- 9 - 9 - - 9 Vac
AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz
Maximum Continuous Output
Current @240V 12.5 16 21 25 32 42 47.5 A
Maximum Continuous Output
Current @208V - 16 - 24 - - 48.5 A
GFDI Threshold 1 A
Utility Monitoring, Islanding Protection,
Country Configurable Thresholds Yes
INPUT
Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W
Maximum DC Power @208V - 5100 - 7750 - - 15500 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage 480 Vdc
Nominal DC Input Voltage 380 400 Vdc
Maximum Input Current @240V(2) 8.5 10.5 13.5 16.5 20 27 30.5 Adc
Maximum Input Current @208V(2) - 9 - 13.5 - - 27 Adc
Max. Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600k Sensitivity
Maximum Inverter Efficiency 99 99.2 %
CEC Weighted Efficiency 99 99 @ 240V
98.5 @ 208V %
Nighttime Power Consumption < 2.5 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)
Revenue Grade Data, ANSI C12.20 Optional(3)
Rapid Shutdown - NEC 2014 and
2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect
STANDARD COMPLIANCE
Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)
Emissions FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG
DC Input Conduit Size / # of Strings /
AWG Range 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG
Dimensions with Safety Switch
(HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in /
mm
Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg
Noise < 25 <50 dBA
Cooling Natural Convection
Operating Temperature Range -13 to +140 / -25 to +60(4) (-40˚F / -40˚C option)(5) ˚F / ˚C
Protection Rating NEMA 4X (Inverter with Safety Switch)
(1) For other regional settings please contact SolarEdge support
(2) A higher current source may be used; the inverter will limit its input current to the values stated
(3) Revenue grade inverter P/N: SExxxxH-US000NNC2
(4) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf
(5) -40 version P/N: SExxxxH-US000NNU4
Single Phase Inverter
with HD-Wave Technology for North America
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/
SE7600H-US / SE10000H-US / SE11400H-US
02/03/20
David Rutti