Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A001.0
SUMP w/ CHECK VALVE, VERIFY LOCATIONOPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATIONPROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE FURNACE PER MECHANICAL PLANS WATER HEATER, PER SPECOPT. WATER SOFTENER, PER SPECRADON VENT PER CODE, VERIFY LOCATION PERIMETER DRAIN, PER SPEC UP 7 RISERS HANDRAIL, PER CODE POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS FLOOR DRAIN, VERIFY LOCATION 4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS 2/8 2/8 SOFFIT PER SPEC ELECTRICAL PANEL (VERIFY LOCATION ON FIELD) DEDICATED GFI \Pw/ GAS WATER HEATER OPT. OPT. DEDICATED GFI FOR EJECTOR PUMP \P(VERIFY IN FIELD) 2/4 2/4(4) 16" SH FAN-\PEXHAUST POST & BEAM PER STRUCTURAL PLANS ADD RISER W/ OPT. 9'-0" POUR DEDICATED GFI FOR SUMP PUMP (VERIFY IN FIELD)LEAD WALL PAST OVERDIG, TYP. (SEE STRUCTURAL)\pxql;PAD FOOTING w/ OUTDOOR FIREPLACE OPTION \A1;11'-5{\H0.75x;\S1#2;}" \A1;3'-6{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}"\A1;15'-4" \A1;20'-9{\H0.75x;\S1#2;}"\A1;12'-0"\A1;1'-0"\A1;9'-5" \A1;5'-7" \A1;1'-9" \A1;3'-5" \A1;8'-11"\A1;1'-4{\H0.75x;\S1#2;}"\A1;1'-4{\H0.75x;\S1#2;}" \A1;3'-6{\H0.75x;\S1#2;}" \A1;1'-7{\H0.75x;\S1#2;}" \A1;1'-11" \A1;4'-1"\A1;12'-9"\A1;23'-11{\H0.75x;\S1#2;}"\A1;11" \A1;48'-7" - OVERALL \A1;31'-9{\H0.75x;\S1#2;}" \A1;16'-9{\H0.75x;\S1#2;}" \A1;14'-0" \A1;17'-6" \A1;12'-0" \A1;2'-0" \A1;30'-6{\H0.75x;\S1#2;}" \A1;11'-0{\H0.75x;\S1#2;}" \A1;6'-9" \A1;1'-0" \A1;11" \P TYP. LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) \A1;33'-7{\H0.75x;\S1#2;}" \A1;29'-7{\H0.75x;\S1#2;}" \A1;48'-7" - OVERALL \A1;20'-1" \A1;10'-6" \A1;18'-0" \A1;64'-7" - OVERALL \A1;30'-11{\H0.75x;\S1#2;}" \A1;64'-7" - OVERALL \A1;11'-11{\H0.75x;\S1#2;}" \A1;5'-0{\H0.75x;\S1#2;}" \A1;1'-9"\A1;2'-6{\H0.75x;\S1#2;}"\A1;8'-3"\A1;2'-2"\A1;16'-3" \A1;8'-11{\H0.75x;\S1#2;}" \A1;1'-9{\H0.75x;\S1#2;}" \A1;1'-8" \A1;5'-3{\H0.75x;\S1#2;}" \A1;11'-11{\H0.75x;\S1#2;}"\A1;3'-3"\A1;1'-9{\H0.75x;\S1#2;}" \A1;3{\H0.75x;\S1#2;}" \A1;47'-7" TO CORNER \A1;7'-4" \A1;6'-1{\H0.75x;\S1#2;}" \A1;12'-10" \A1;SHOWER\A1;SHOWER \pxql;2/8 \A1;1'-7{\H0.75x;\S1#2;}" \pxql;2/8\A1;1'-7{\H0.75x;\S1#2;}" \A1;11" \P TYP.\A1;11" \P TYP. 123456712345672A2 B.1 1A2 B.1 1A2 B.1 2A2 B.1 3A2 B.2 4A2 B.2 4A2 B.2 TP TR TBCONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS) 3A2 B.2SLAB/UNEXCAVATED (SEE STRUCTURAL PLANS)FINISHED BASEMENTSLAB (SEE STRUCTURAL PLANS)STORAGELBATH 7HVACSLOPE GAS VALVE OPT. GAS VALVE UNEXCAVATED(SEE STRUCTURAL PLANS)CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS)CONCRETE SLABA0.01 FOUNDATION - BASEMENTMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019 PROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Allison II 2377.300Home for * Market Home *, 6838-01100#313027 Chenille Drive, Carmel, IN 46074BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 02/10/20 Adam Schriner