HomeMy WebLinkAboutGNO10.0#1
of 8
Date:
11.25.19
Sheet:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.Grigsby ResidenceBasement RemodelBrian & Tina Grigsby1991 W. 116th StreetCarmel, Indiana 46032Approved By:
Date:
Jessica Seljan
Lead Designer
jseljan@caseindy.com
G002
FINAL
Megan Nagy
Designer
mnagy@caseindy.com
G ENERAL / CONSTRUCTION NOTES
DEMOLITION NOTES ELECTRIC NOTES
BASEMENTBASEMENT
F/I (2) TWO NEW LED RECESSED CANS ON
NEW 3 WAY DIMMER SWITCH FOR STAIR WELL
F/I (4) FOUR NEW SHALLOW DEPTH LED
RECESSED CANS ON NEW 3 WAY DIMMER
SWITCH
F/I (6) SIX NEW SHALLOW DEPTH LED
RECESSED CANS ON NEW 3 WAY DIMMER
SWITCH
F/I (11) ELEVEN NEW OUTLETS PER CODE
F/I (1) ONE NEW INTERCONNECTED
COMBINATION CARBON MONOXIDE SMOKE
DETECTOR
BRIAN'S BUNKERBRIAN'S BUNKER
F/I (5) FIVE NEW SHALLOW DEPTH LED
RECESSED CANS ON NEW DIMMER SWITCH
F/I (5) FIVE NEW OUTLETS PER CODE
WELL PUMP WELL PUMP ROOM
F/I (1) ONE NEW BARE BULB ON NEW SWITCH
MECHANICAL ROOMMECHANICALROOM
F/I (1) ONE NEW BARE BULB ON NEW SWITCH
F/I (1) ONE NEW INTERCONNECTED
COMBINATION CARBON MONOXIDE SMOKE
DETECTOR
R/H ELECTRICAL & UNNECESSARY
WIRES
R/H CARPET ON STAIRS & STAIR
HANDRAIL
R/H DOWN DRAFT VENTING FROM
EXISTING COOK TOP
PROPOSED NOTES
F/I NEW FLOOR JOIST & HANGERS AS NEEDED
FROM REMOVAL OF DAMAGED FLOOR JOIST
F/I NEW 2X4 ONTO EXISTING CEILING JOIST TO
CLEAR PLUMBING
FUR 2X2 WALLS ON NOTED WALL; F/I NEW FOAM
INSULATION ON THE FURRED OUT NOTED WALL
FRAME NEW 2X4 WALLS, OPENINGS, BULKHEADS
& COLUMNS
F/I NEW ACCESS PANEL TO EXISTING PLUMBING
CLEAN OUT & CRAWL SPACE; FIELD VERIFY SIZE &
LOCATION
FRAME & INSTALL DRYWALL AROUND EXISTING
ELECTRICAL PANEL TO BE EXPOSED
F/I NEW HVAC SUPPLY & RETURN AIR DUCTING
FOR NEW BASEMENT ROOM ADDITIONS
F/I NEW BATT INSULATION ON EXTERIOR WALLS
INSTALL & FINISH NEW DRYWALL ON WALLS,
BULKHEADS, COLUMNS & CEILINGS
F/I NEW PREHUNG SLAB DOORS & DOOR
HARDWARE; SEE DOOR SCHEDULE FOR DETAILS
F/I NEW BASE MOLDING & DOOR CASING
F/I NEW PAINT GRADE STAIRS HANDRAIL; H.O.
PROVIDED PAINTING
#2 12.23.19
#3 01.14.20
#4 01.30.20
02/11/20
David Rutti