HomeMy WebLinkAboutVIOC CARMEL, IN - M-1MECHANICAL GENERAL NOTES 1. ALL RECTANGULAR, ROUND AND RE%IBLE DUC1S SHALL BE SIZED AS SHOWN ON THESE DRAWINGS. MINIMUM INiERNAL DIMENSIONS ARE GWEN. 2 ALL SOPPLY & RENRN AIR DOCTS ARE SRE� FOft AIR VOWAIE ANO STAIIC PRESSIIRE �ROP PoIHOOT WiERIOR INSOLAlION. 3. INSiALL NRNING VANES IN ALL 90' DUCT ELBOWS AN� AT ALL DUCT "iEES' 4. ALL �UCTWORK SHALL BE FABRICAiE� AN� INSTALLE� ACCOR�ING TO RIE MOSi RECENILY P09LISHE� ASHRAE AN� SMACNA SiAN�AR�S. 5. RECTANGULAR METAL DUCT SHALL BE MILD GALVANIZED STEEL UNLESS NOIED OTHER'MSE OR APPROVE� BY OWNER. fi. MANUFACiIIRERS MINIMl1M CLEARANCE RECOAIMEN�A710N5 SHALL BE MAINTAWED ON ALL EOUIPAIENi AN� �OCiWORK. 7. THE CONIRACTOR SHALL CAREFULLY COORDINAIE 1HE LOCATION OF ALL DUCTS, GRILLES, DIFfU5ER5, ETC. 'M1H 7HE CEILING GRIDS AND iHE PWMBING AN� FRAAIING CONTRACTORS. 8. ALL CONWOL WIRING SHALL BE BV THE HVAC CONiRACTOR. 9. E%HAlIST FANS SHALL BE FIIRNISHED Wlhi BIRDSCREENS, BACKDRAFT DAMPERS ANO DISCONNECTS WHERE APPLICABLE AND ACCOR�ING TO hiE SCHEDULE. 10. CONTRACTOR TO BALANCE SYSiEM. 11. hIE CON7RACTOR SHALL CAREFULLV COORDINAIE Al1 THERMOSiAT LOCATIONS R1hi WIERIOR FlNISHES VERIFY LOCATIONS WITH INIERIOR ELEVAlI0N5. 12 hIE WN7RACTOR SHALL COOPERAIE FULLY BETWEEN ALL OhIER 7RADE5. 13. 1HE SUBMISSION OF A BID OR PROPOSAL W1LL BE CONSTRUED AS ENDENCE 1HAT THE CONIRACTOR HAS FAMILIARIZED HIMSELF WI1H THE PLANS AN� BUILDING SIIE. CLAIMS MADE SUBSEOVENT TO 1HE PROPOSAL FOR MAIERIALS AND/OR LABOR DUE TO DIFFlWLPES ENCOUNIERED PoLL NOT BE RECOGNIZED, UNLESS iHESE DIFFIWLPES COULD NOT HAVE BEEN FORESEEN EVEN THOUGH PROPER E%AMINAlION HA� BEEN MADE. 14. iHE PWMBINC CONIRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL GAS PIPING. ALL GAS LINES SHALL 9E SCHE�ULE 40 9LACK IRON AN� MSTALLE� I.A.W. 1HE LAiEST E�I➢ON OF N.F.P.A. 3�-]] FLAMMABLE ANO COMBUSIIBLE LIOUI�S CO�E), FIRE PREVEN110N CO�E AN� ANY APPLICABLE SiAiE OR LOCAL CO�ES. 1i ALL ROOF CIIRBS FOR FANS, EiC. SHALL BE A MINIMl1M OP 12" HIGH. 1fi. PROPERLY SECURE ALL FANS i0 WRBS & OUCiWORK. PRON�E NECESSARY GASKEi ON CURBS i0 PREVENi WAIER PREVENiION. 17. ALL POWER WRING SHALL BE BY 7HE EIECTRICAL CONiRACTOR. MECHANICAL PLAN NOTES 1. GROUN� MOUM FURNACE PER MANUFACTURER'S RECOMMEN�ATIONS. CONCENTRIC VENT LWE FOR COMBUSTION AIR MTANE / EXHAUST FROM GAS FIRE� EOUIPMEM TO ROOF TERMINATION KIT. ROUTE PIPING WIiH MINIMAL AMOUNi OF BENDS AND MINIMUM LENGiH AS REQUIREO BY RESPECiIVE UNIi MANUFACiURER�S REQUIREMENiS. LOCAIE A MINIMUM OF 10�-0° AWAY FR�M ANY FRESH AIR INIAKE. SEE PWMBING PIANS FOR GAS AN� WNDENSAiE PIPING. 2 INSTALL LINE-SEi AND 4-C�N�UCTOR COMROL WIRING FROM ROOF-MOUNTE� CON�ENSING UNIT TO FURNACE DOUBLE INSUUTE AND PROTECT EXTERIOR LWE-SEf USING 2" FOAM WRAP AND SCH.40 PVC WNDUR i0 ROOF PENEfRAiION. INSUTAiE BOiH LIQUID AN� SUCiION LWES INSIDE BUILDING USING 1" FOAM WRAP. PROVI�E ADDIiIONAL REFRIGERANi WHERE LENG7H OF LINE-SEf EXCEEDS FACTORY CHARGE CAPACITY. MAKE FlNAL CONNECTIONS. MECHANICAL COMRACTOR IS RESPONSIBLE FOR SEALING ALL BUIL�ING PENEiRATIONS FOR MECHANICAL E�UIPMEM WATERTIGHT, COORDINATE WIiH 07HER iRADES. COORDINAiE EXACT INSiALIAiION LOCAiION OF CONDENSING UNIT WITH ARCHRECTURAL SHEEfS. 3. REFRIGERANT LINES. SRE PER MANUFACNRERS RECOMMENDATIONS. 4. 6"0 O.A. INTAKE UP TO GOOSENECK ON ROOF, 100 CFM. ROUTE TO REAR ROOF SLOPE, REFER i0 ARCHIIECNRAL ROOF PLAN. 5. PROVIDE 4"0 COMBUSiION AIR INTAKE DUCT TO AN ALUMINUM GRILLE IN SOFFli W�AN ALUMINUM INSEC7 SCREEN. CRILLE SHALL HAVE A PREE AREA OF 72 SQ.IN, SEAL AROUND GRILLE COORDINAiE WITH SOFFli CONSIRUCTION. 6. iRANSFER AIR FAN iF-1, HANG FROM SIRUCNRE ABOVE Wlhi UNISIRUT, hIREADED RODS AN� NBRAlION ISOLATION PROTEC➢ON. PROVIDE FLE%IBLE WNNECiORS.INiERLOCK w/EF-2. 7. REGIS7ER � 1515 CFM W/ 24"x20" DUCT iRAN51ilON TO iRANSFER FAN oucT coNNEcnoN. Paov�oE F�Ezie�E coNNEcnoN ro FnN. aRONOE NRNING VANES AT ELBOWS. 8. hiERMOSiAi YARING IN 1/7' CON�UIi. Al1 i57A1S i0 BE LOW VOLiAGE PROGRAMMABLE SiA15. i1PICAL 9. INTERLOCK EF-2 FAN MOTOR W17H PIT LIGHIING SWITCH. 10. RADIANT HEAiER, MOUNi i0 ROOF SIRUCNRE, INSURE PROPER CLEARANCE FROM GARAGE DOORS ANO COMBUSTIBLE MAiERIALS, TYPICAL OF 7. 11. 4"0 T1PE "B" FWE UP THROUGH RWF WITH WEATHERCAP, iYP. OF 3. ROUIE TO REAR ROOF SLOPE, REFER TO ARCHITECNRAL ROOF PLAN. 12. BALANCING DAMPER, TVPICAL. 1J. SEE PWMBING SHEETS FOR GAS CONNECiION. 14. INLWE FAN MOUNTED IN TRUSS SPACE PER MANUFACTURERS INSTRUCTIONS. PROVIDE FLE%IBLE AT CONNECTIONS. 15. ifi"xi6" UP TO VENTILATOR VENPLATOR SHALL BE GREENHECK MO�EL �GRSR-ifi OR EOUAL MAINiAIN 10'-0" MIN TO OOTSIDE AIR INTAKE. PROVI�E AND INSTALL BACK�RAFT �AMPER. 16. 20"x17' DUCi UP i0 EF-2 DOWN i0 17' AFF WIiH HAR�WIRE CLOTH. D. EF-1 IN CEILING. 18. 18"x14" SUPPLY AIR DUCT DOWN THROUGH CHASE BELOW TO LOWER LEYEL BELOW REFER TO LOWER IEVEL MECHANICAL PLAN FOR CONTINUA710N. 19. 20"x17' E%HAUST �UCT UP IN CHASE FROM LOWER LEVEL BELOW. zo. is",is" exnnust oucr to Rise ua iNto teuss sPnce. 21. COMBOSTION AIR INTAKE DUCT TO RISE THROUGH CEIIJNG AND RON IN ATPC SPACE TO INTANE GRILLE IN SOFFIT. zz ExrENo a" ExHnust niR ouct uP NRoucH RwF ro vENt cna. RELEASED FOR CONSTRACTION u F�ooa naov�. Su6jec��ocompliancewithallregula�ions LE� ON FACE OF CEILING. o4S�a�e antlLocalCodes P17 EXHAUSi DUCIVIORK SEE ELECIRICAL City of Carmel �IAGRAM. AIR SW1iCH i0 9E QEVELAND oR Eoun�. `�s��� �\o,v�AwnT� MECHANICAL LEGEND � suaP�r niR oirrusER � REIlIRN/E%HAOST AIR CPoLLE � SUPPLY AIR DUCT: UP� DOWN � RENRN�E%HAUST AIR DUCTI UP� DOWN ��� AIR PATiERN DESIGNAiION (1-WAY, 2-WAY, 3-WAY) � �UCIWORK 1RANSI110N; CONCEN7RIC, ECCENiRIC - N FlRE DAMPER (PROUIDE ACCESS �OOR FOR RESET) Fo - VOLUME CONTROL �AMPER M MOiOR OPERAiE� OPPOSE� BLA�E �AMPER FLEXIBLE �UCiWORK iIIRNING VANES OA OUTSI�E AIR �UCiWORK TO iHERAlOSTAT EF-1 EXHAl15T FAN DESIGNAiION AFF ABOVE FlNISHE� FLOOR M.C. MECHANICAL CONTRACTOR G.C. GENERAL CONiRACTOR RH-1 RA�IANi HEAIER �ESIGNAPON EWH-1 ELECiRIC HEAiER �ESIGNATION E�H-1 ElEC1RIC DUCi HEAIER �ESIGNAlION iF-1 iRANSFER FAN �ESIGNAlION CU-1 HEAT PUMP DESIGNAiION FI FURNACE UNIT DESIGNATION LOWER LEVEL EXHAUST CALCULATIONS CALWLAPONS TO COMPLY W11H N.EC. 511-36 FOR (6) AIR CHANGES PER HOl1R. 1690SF x 7.88' x fi = 1331 CFM RE�IIIRE� fi0 MORE SiRINCENi NFPA 30A FOR 1 CFM/SF. 1690SF x 1= 169� CFIA RE�OIRED. USE 1690 CF�A. � CHANGING ROOM � m � BREAK AREA IL =„ I F I II STAIR LOWER I I LEVEL t � �_i LIIBE PIT BULK OIL � ��� -� . �� .� � LOWER LEVEL FLOOR PLAN SCALE 1 /4" = 1'-0" 2 CU-1 i -\ \_% ..,...,m�l . � � I' �--/ STORAGE�I� � �� IIROOM ff- - 4 � E/1515 ........__ I i�ioo c/aoo ......_ ;' �i ...,.,. �� -_ �� H/iao � F-1 1 � e ... �. - A/300 _ iF-1 ,. .�DH-1. . 6 18 �dlm EF-1 17 UN� z2 RESTROOM B/75 ° a' I 'N �I � O 1 10"0 VD F-� 12 n aoo c/aoo WAIPNG nREn l�� � �� - � scn�e: t/a" = t 0 �I ,�� � r` L _ r1 N M O � Ll.� � � z z - a J = 11.� U J d' =�OU yaa o � (n O z � LL� Q z (� O U Q� % Z ll7 M W W QC 2019 CESO, WC .9„���,���„�nn„�i ,1,�7,"N�H, sHEpqR%,,,, ;'\P,-V�STEq ,�S': _�;"�� FO'.2; '- y � No.PE10809267 ;� - . ..rnr[ 11F '.�i«:v� 756309-01 "" AS NOTED ,r.,� WHS =r"" ` WHS ��a os.os�a ..r ,i'9-Lc Mechanical Plans , �-9u, M-1 DATE: OZ�� 3�ZO