HomeMy WebLinkAboutVIOC CARMEL, IN - P-3BY GAS COMPANY (VERIFV) BY PWMBING CONTRACTOR
PRESSURE TEST COCK EXTERIOR BUILDING WALL
GAS PIPE UP EXTERIOR WALL.
GAS MEiER BY SIZE AS SHOWN ON PLAN.
GAS COMPANY c9 USE BLACK STEEL PIPE.
ANCHOR R6ER TO WALL Ai
PIPE TEN FOOT WTERVALS USING
INCREASER OFFSET RISER PIPE CLAMPS
� o �
O i PIPE WCREASER AS/IF
LBYPASS REQUIRED.
STRAMER VALVES PROVI�E 6" LONG DIRT LEG
SHUT-0FF � GRADE OR AT BOTTOM OF RISER
VALVE � PAVEMENT FLOOR
PRESSURE REGULATOR TO REDUCE PRESSURE TO 7" WC.
VEPoFY REQUIREMENTS FOR METERING AN� PIPING WITH GAS COMPANY.
INSTALL OTHER UTILITIES MINIMUM TEN FEET FROM GAS LINE PLUMBING
CONTRACTOR SHALL PAY ALL GAS COMPANY FEES POR INSTALLATION.
USE WELDED OR SCREWED PIPE AND FlTiINGS PER PWMBING SPECS.
GAS COMPANY SHALL EXCAVATE, BACKRLL, AND REPAIR ANY PAVING
OR SOD FOR GAS SERVICE LWE INSTALLATION FROM MAIN TO BUILDING.
GAS SERVICE ENTRY
No S�A�E
�RIM: REFER TO CINL PLANS
�
NOTE: REFER TO CML PLANS
FOR FINAL SUMP PUMP
MANHOLE LOCAPON AND
A�DI710NAL INFORMATION
STEPS 16" O.G (NEENAH CAT. N(
R-1981-W OR EQOAL)
4' INSI�E GRAVITY MLEi
PROM FOUN�AiION DRAIN
INV: 2'-0" BELOW FOUNC
CAST IRON MANHOLE FRAME AND
LID. (NEENAH FOUNDRY N0. R-2570
W/ CONCEALE� PICN HOLE, OR
EWAL)
�ELECTRIC COR� W/ PWG END AN�
SIAMLE55 51EEL CABLE ID LIF1
— GRAUITY OU7LET -
REFER i0 CIVIL PLANS
7' PVC DISCHARGE PIPE
CHECK VALI�E ASSEMBLY
6" DRAIN INV. _ (V.LF.)
SUMP PUMP - REFER i0 PLUM9ING PI%NRE SCHE�ULE
NOIE: � PRECAST CONCREIE FLOOR W/4"
PRON�E AUDIBLE/VISUAL ALARM W SAND CUSHION
OFFlCE TO NOiIFY OWNER IN iHE
EVENT OF PUMP FAIWRE.
FOUNDATION SUMP PUMP MANHOLE
NO SCALE
BACKFLOW PREVENTER 1-1/2'
CONNE
1-1/2'� SiRAINER:BRONZE BODY,SCREWED, VALVE'
STAMLESS STEEL SCREEN
1-1/2° MEiER
PROVIDED BY � �
UTILITY PROVIDER
UNION TypICAL BALL VALVE.
(TYPICAL) � �_��Z�• BRONZE BODY,
Il SCREWE� CONNECilONS
COPPER TUBE
,—,i�� WATER
SERVICE ENTRY
TO 6" ABOVE
FLOOR WIiH
SLEEVE ANO
cnu�e—
PIPING
IZE BODY SCREWED
PRESSURE REDUQNG
50 PSI �
`1-1/2" BRONZE SHUT-0FF VAWE,
scREwEo, REsiuENt sEntEo, NRs.
DO NOT USE A QUARTER TURN VALVE
FLOOR SLAB
SHOWN IN SCHEMATIG ADJUST TO SUIT FIELD CONDIilONS. PROVIDE
HORIZONTAL UPRIGHT POSITION. PROVIDE ANY RE�UIRED CERTIFlCAiION OF TEST OF BACKFLOW
PREVENTER TO LOCAL AUTHORITIES. ALL ITEMS SHALL BE APPROVED FOR DOMESTIC WATER
SERVICE INSTALL BACKFLOW PREVENTER SO IT CAN BE EA9LY SERVICED AND TESTED.
SUPPORT ASSEMBLY FROM WALL BRACKET OR FLOOR STAND.
DOMESTIC WATER SERVICE ENTRY
N� S�A�E
NOT USED
NO SCALE
RELEASED FOR CONSTRl1CTI0N pUMP/OIL SEPARATOR SCHEMATIC
Su6jec��o compliance with allregula�ions 1��
04 S�a�e antl Local Codes
City of Carmel
y�,:�v��� �'�a;,v��tiw� �
�
DATE: OZ�� 3�ZO
G ,
�
n
SHUi OFF VALVE - LOCAIE
3�-0" MA%. AWAY FROM WATER
HEATER
VACUUM RELIEF VALYE, LOCAIE
VALVE ABOVE LEVEL OF TANK
TOP
3/4" HW SUPPLY
FACTORY INSTALIE� T&P
VALVE EXIEND PIPE FULL
sac To cxTERioR.
ZX
�i
' N�
ro co�o wnrER
:I IPPI V �
�
�n
SAFETY PAN:� DO NOT LOCATE BOTTOM
1 1/2" DEEP MIN. OF TANK IN PAN. PRONDE
24ga GALVANIZED S7EEL OR W00� OR BRICKS i0 ELEV-
1/ifi" THICK HIGH IMPACT PLAS7IC ATE TANK. �
1" SAFEiY PAN �RAIN; E%iEN� FULL SIZE i0 SINK
WATER HEATER SCHEMATIC
NO SCALE
I PIPING tlY PWMtlING WNIHACIOH AhItH
1ANKS ARE INSIALLED. COORDINAIE ROOF
PENETRATIONS PRIOR TO INSTALLAPON.
WASiE OIL
VENT
MAIN LEVEL
�r
FINISH GRA�E CLEAN OUT BO% (STAMPE� "CO") MAX 7�
(CONCREIE, GRASS CLEAR AT TOP OF CLEANOUT
ETC.) 1" CROWN
�30" X 30'� X 6" CONCREIE PAD (SLOPE PAD
IN GRA55 AREA ONLY.)
CLEAN OUT PLUG
c�eaN aut eax to ee
IN�EPEN�ENT OF PIPE
NOTE: ALL 0.EANOUTS SHALL BE FLUSH N1TH iHE
ELEVAiION OF THE SURFACE IT IS BEING INSTALLED ON
WHEiHER IT BE GRASS OR CONCRETE INSTALL PER ALL
APPLICABLE CO�ES.
EXTERIOR CLEANOUT DETAIL
NO SCALE
Ho�o
``„Is
� ���
- PROVIDE AND INSiALL PRESSURE VAWUM
VENT AT EACH FRESH OIL TANK PER
MANUFACTORER'S REOUIREMENTS. MORRISON
� BROS. W. MODEL 7495 OR EQOAL.
ioi
TANK VENTING RISER DIAGRAM
ND S�A�E
n
�1-1/7' UP FROM
� 1 LAUNDRY iUB SUMP PUMP
i �
i
/ I
/
/� �
/ II
`\\�� ��2� u'�
[l 1
\ [�_��p^ �� 3..ViR
�
1-1/7'��^u
� J�� rv,R
��ae \�j���-�/�'�
�I I .
I �� I
�OSq I �Z" T�
��o.. I �—�/z"�� ��
u
P5
�� �
I O P9
�
TO SUMP VENT
a' Pvc v�Nr uP iN wn�� - RourE ro vTR oN
ROOF
— (2) 4" PVC SHORT-SWEEP ELBOWS - PROVIDE
ESCOTCHEON � WALL & FLOOR PENEiRATIONS
(45 ELBOWS ARE ACCEPTABLE)
— FLOOR �RAIN AS SCHEDULE�
���.�. 4" CONC. TOPPING
� 12" HOLLOW
CORE SLAB
CORE �RILL H.C. AS REQb � NON-iEN�ON
AREAS ONLY (V.LF.)
� �4" PVC TRAP
END VC EESPLANN& R SEREROUGHTINLAN�
INSTALL PIPING AS HIGH AS POSSIBLE TO
INSURE �AAKIMUM CLEARANCE 7HROOGHOUT
... . SPACE WHILE MAINTAINWG PROPER SLOPE.
FLOOR DRAIN WASTE/VENT DETAIL
SCALE: 3/4"=1'-0"
I ��� JI�
I \� ?�f
� 4 J ��\ �~
I �
I �`
I ��
�
� �
.
� �
.
� \
U \\ \
�
�
P6 ��
�
�\
�
�
a"��.
\\�
�
I
I
I
�
rrN Pfi �
/ �� �
/ �J
n
SOIL, WASTE 8� VENT RISER
NO SCALE
� e
_� I rl s o eo I I r eexa�
E
�
w
¢
z
0
N
M
O
W �
U` Z
Z —
2W
U
J �
OU
H
o � F Q
o � � �
Z �
Z
Z (�
J =
�
U
Q �
� Z
�
M
�
rn
WC
,1,q;N N, a�cv/�i.,,
;'\P,�V�STER •�S
\ ;�� F�. �
: y ; No.PE10809267 ��
- . ..rnr[ 11F .
°��i=yv�. 756309-01
; °', ns NorEo
�...� WHS
::u_�:� WH£
� oa.oa�=
]rezi'9 ill�:
PLUMBING
DETAILS
,.,�-g�o P 3