HomeMy WebLinkAbout20010083 State CDRELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 1/2
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on:January 17, 2020
Project number Release date
412136 01/17/20
Construction type Occupancy classification
Scope of release
V-B S-1
Type of release
Project name
Street address
City County
ARCH ELEC FDN HOOD MECH
PLUM STR
Standard
Valvoline Instant Oil Change
9835 N Michigan Rd
CARMEL HAMILTON
To: Owner / Architect / Engineer
CESO Inc
Benjamin T Bell AR10500002
1305 NE McClain Rd
Suite 7
Bentonville AR 72712
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
14B
14B100815
14B100816
14M0920
14B041243
14B11092
14M050131
14M05021
14M05063131
14M0510
AREL
This project has been reviewed under the 2014 Indiana Building Code.
There shall be a floor or landing on each side of a door in accordance with Section 1008.1.5, IBC
(675 IAC 13-2.6).
Landings at doors shall be designed and dimensioned in accordance with Section 1008.1.6, IBC
(675 IAC 13-2.6).
Suspended-type unit heaters shall be installed and supported in accordance with Section 920, IMC
(675 IAC 18-1.6).
An oil separator shall be provided and designed in accordance with Section 412.4.3, IBC (675 IAC
13-2.6).
Each toilet room and bathing room shall be handicapped accessible in accordance with Section
1109.2, IBC (675 IAC 13-2.6). (Clear turning radius, Door Swing, Grab Bars, Fixture Clearances,
Fixture Mounting Heights, Shower/Bathtub seats)
The termination point of exhaust outlets and ducts discharging to the outdoors shall be located in
accordance with Section 501.3.1, IMC (675 IAC 18-1.6).
Exhaust systems shall be provided, maintained and operated as specifically required by Section
502.1, IMC (675 IAC 18-1.6).
Exhaust outlets that terminate above the roof shall have the discharge opening located not less than
40 inches above the roof surface in accordance with section 506.3.13.1 IMC (675 IAC 18-1.6).
Hazardous exhaust systems shall comply with the requirements of Section 510, IMC (675 IAC 18-
1.6).
Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from
required compliance with all applicable rules of the commission, even if noncompliant conditions
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
8882084826, richard@cesoinc.com
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
appear in the plans and specifications that have been filed with the division. The owner is
responsible for correcting any and all areas of noncompliance even if they are discovered
subsequent to the issuing of this design release.
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will
be final, and you must comply with its requirements.
Code review official
Address (name,title of local official,street,city,state and ZIP code
KEVIN HANSON
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL,IN 46032
DEPT OF COMMUNITY SERVICE
Fax & e-mail: 3175712499, jblanchard@carmel.in.gov
Indiana State Building Commissioner khanson@dhs.in.gov