HomeMy WebLinkAboutCarmel Project A121LEGEND
NEW OR RELOCATED
�LIGHi FIXiURE.7x4'.
BUILDING SiANDARD LED.
PROVIDED FROM BUILDWG
SiOCK; COORDINAiE WIiH
PROPERiY MANAGEMENi
SUSPENDED IJNEAR, 8'-0"L,
� BUILDINGSiANDARDLED;
HEIGHi MOUNiED Ai: iDB
� LIGHi FlXiURE PENDANi,
$500 MAiERIAL COSi
ALLOWANCE PER
PENDANi; HEIGHi
MOUMED Ai: iBD
NL NIGHi LIGHi
(1 E%li LIGHi FIXiURE
� EMERGENCY IJGHi FIXiURE
�N LIGHiSwIiCH
�Na uGHiSWIiCH,3-WAY
$ND �IGHiSWIiCH,DIMMER
$NG SWIiCH,GARBAGE
DISPQSAL (ABOVE
COUMERiOP)
. — . ucNrcirecmr
CEWNG GRID,
SUSPENDEq 2'x4'
❑ EXPOSEDiO DECK
EXISTING TO REMAIN
�LIGHi FIXiURE.7x4'.
FWORESCENi, PARABOLIC
� LIGHi RXiURE
PENDANi
� E%li LIGHi FIXiURE
� EMERGENCYLIGHiFlXiURE
$ LIGHiSWIiCH
�3 IJGHi SW IiCH, &W AY
�p LIGHiSWIiCH,DIMMER
$� SWIiCH,GARBAGE
DISPOSAL
: �'�� uGHrciRcuir
CEWNG GRID,
SUSPEN DEq 2'z4'
GENERAL NOTES
I. REUSEE%ISTINGCEIIJNGGRIDANDTILEl1NLESSOTHERWISENOTED.
EXISiW G GRID IS 2x4 Ai 10'-9" A.F F. iILE$ ARE 2x4 ARMSiRONG
SECONDLOOKCORiEGAIIACOUSiICALLAYINiILES. REPAIRANY
DAMAGED GRID AND REPLACE ANV DAMAGED TILES WITH NEW TO
MAiCH EXISiWG-
2. IF IN GOOD CONDIiION, EXISiING CEILING iILES SALVAGED FROM
DECONSTRUCTION CAN BESUBSTITUTED FOR NEW. PROVIDE LIKE
CEILWG iILES IN INDIVIDUAL ROOMS WHERE POSSIBLE i0 CREAiE
UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHiING IN iENANi SPACEAS REQUIRED PER
NEMA AND IBC- EMERGENCV BAiiERV PACKS OR LIGHiS
CONNECiED i0 AN EMERGENCY POWER SOURCE ARE REQUIRED IF
iH ESPACE CONiAINS 50 PERSONS OR MORE RXiURES SHOW N ON
PLAN ARE f-0R REFERENCE ONLV. IN RECEPTION AREAS.
CONFERENCE ROOMS AND OiHER HIGH PROFlLE AREAS W IiHIN
SUIiE ALL LOCAiIONS OFSUCH DEVICES MUSi BE APPROVED BYSDI
OR TENANT PRIOR TO INSTALLATION. FAI W RE TO DO SO MAY RESULT
W CONiRACiOR RELOCAiWG iHESE IiEMS Ai iHEIR EXPENSE
4 LAYOUiSHOWNISINiENDEDiOMEEiASHRAE90.ISiANDARDS.
ELECiRICAL CONiRAQOR IS RESPONSIBLE FOR COMPLIANi
WSTALLATION. IF ADJl1STMENT IS REQl11RED TO MEETASHRAE 90J.
CONiRACiOR MUSi NOiIFY SDI_
5. ALLNEWSWIiCHESiOBEOCCUPANCYSENSORS;PROVIDECOMBO
UNIiWIiHBOiH ULiRASONICANDWFRAREDiECHNOLOGVWIiHA
ONE BUiiON OVERRIDE_ OCCUPANCV SENSORS AREiO BE
LOCAiED SUCH iHAi OCCUPANCY WIiHIN ANY PORiION OF
INCWDEDAREAISDETECTED. PROVIDECEIIJNGMOl1NTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED_
6. NEW DEVICES AND FACE PLAiES iO BE WHIiE. WHERE POSSIBLE,
GANG MULTIPLE SWITCHES TOACCOMMODATE MULTISW ITCH PLATE
W HEN SWIiCHES ARE SHOWN ADJACENi ON PUN.
]. ELECiRICALWORKISLIMIiEDiOADESIGN-BUILDSCOPEANDIS
OUiLWEDINiHESEDRAWINGS. ALLELECiRICALWORKISLIMIiEDiO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHiWG iHAi DO NOi EXCEED iHE CAPACIiY OF iHE EXISiWG
ELECiRICALSERVICHN iHE BUILDING. ELECiRICAL CONiRACiOR IS
TO NOTIFV APPIJCABLE PARTIES IF ADDITIONAL W ORK IS REQl11RED
SO iHAi ADDIiIONAL PUNS CAN BE FlLED AND MUA COMPLV W IiH
ALL APPLICABLE CODES.
8. ALL REQUIRED MECHANICAL DRAW INGS TO BE PROVIDED BY
OiHERS.
9. REMOVE EXISiWG LIGHi SWIiCH Ai DOOR 09 AND REPLACE WIiH
NEW 3-WAYSWIiCH ANDSINGLESWIiCH FOR iHE MARKEf 109
PENDANTS. GANG S W ITCH ES W ITH ONE PLAT6 REFER TO CEIIJNG
PUNS FOR MORE WFORMAiION.
PLAN NOTES
R01 CONTROL WELCOME 101. HOMEPAGE I I I. AND COFFEE 109
IJGHiWG WIiH &WAY SWIiCH AiiH1S LOCAiION_ PROVIDE
MULiIPLESWIiCHESAS REQUIRED.
IN AREA TO BE E%POSED TO DECK. REPLACE LOW PRESSURE
R02 SUPPLVBRANCHLINEDUCiANDWIiHNEWRIGIDSPIRALDUCi
AND ROUND SUPPLY DIFFUSERS AS REQUIRED. QEAN AND
PREPARE f-0R DRVFALL PAIM �Pi3�-AS SPECIFlED, PAIM E%ISiWG
EXPOSED CEILING DECK, SPRINKLER PIPING, JUNCiION BOXES,
CONDUIi,SiRUQURALBEAMS FlREPROOFlNG, HC.IN
ACCORDANCE WITH NFPA 13 6.3.8.
�
�
�
�
�w
— ,
O Y
J
N b O J
� Q o �
JJ
N Z � '
+ n L
� J
� .� � .
o` Q� J
� o m �
O C
I y � O $
� 5
I
rHis orenwiNG, nNo m e ioens.
DESIGNS AND CONCEPiS CONiA W ED
HereeN. nree rHe Excwsive
IMELLECiUAL PROPERiY OF SCHOii
DESIGN, WC.,ANDARENOiiO BE
USE� oR REPRo�UCE� iN wHo�E, oR
IN PqRi, wIiHOUi iHf wRIIIfN
GONSENi OF SGHOII DESIGN.
�
Uo
� J
� LL
�
i � �
� O
O "' � �
N Z
�
HWQw
W � p �
5���
`U� �
OZ
��
M
� �
�
�
ISSUE
DAiE DESCRIPiION
OI.V.40 RENEWSEi
01.20.20 PERMIiSEi
REVISIONS
MAR DAiE DB DESCRIPiION
RELEASEU FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
y\0.v��i �\p;,V`iiY?A i)
\
DATE: OZ��4�ZO
/
/
/
IV �.
AR10700017
STATE OF
PROJECT NUMBER
2019.473
PROJ. MGR DRAWN BY
CB CB
1ST FLOOR
REFLECTED
CEILING PLAN
A121
� AREANoi�N�oNiRA�i REFLECTED CEILING PLAN �
❑ AREA OF WORK 0 3' 4' 8' 16'
■ � -