HomeMy WebLinkAboutE100.0-E100-LIGHTING PLANRELEASED FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
�Sv�� �'l'�^l�`�pNil
\
DATE: OZ�1 H�ZO
GENERAL NOTES:
A. 120 VOLT BRANCH CIRCUITS M EXCESS OF ]5' SHALL HAVE
CONDUCTOR S2E INCREASED A MINIMUM OF 1 CONDUCTOR SIZE.
INSTALLMG CONTRACTOR SHALL DETERMMEACTUAL CONDUCTOR
SIZE TO BE INSTALLED TO ADHERE TO VOLTAGE DROP REQUIREM ENTS.
B. LMEAR FLUORESCENT LUMINAIRES SHALL BE INSTALLED TO MEET THE
REQUIREMENTS OF NEC REGARDING LOCAL DISCONNECTING MEANS.
C. PROVIDESTAINLESSSTEELCOVERRINGSATALLTHRUWALLAND
CEILING PENETRATIONS.
KEY NOTES:
� � � ELECTRICALCONTRACTORTOPROVIDEJUNCTIONBOXWITHTOGGLE
DISCONNECT SW ITCH W ITHIN 5 FEET OF SIGN IN ACCESSBLE
CONCEALED SPACE. SIGN FURNISHED AND INSTALLED BV SIGN
CONTRACTOR. FlNAL CONNECTION OF SIGN BV ELECTRICAL
CONTRACTOR. SEE ARCHITECTURAL PLANS FOR SIGN LOCATION TO
DETERMINECONDUITANDROUTING. ALLOUTLETS,BOXES,CONDUIT,
ETC. SHALL BE CONCEALED FROM VIEW. COORDINATE EXACT
LOCATION W ITH TENANT PRIOR TO ROUGH-IN. SIGN CONTROLLED VIA
INTEGRALPHOTOCELL.
2� CONNECT EXITIEMERGENCV AND NIGHT LIGHTS TO LOCAL LIGHTING
CIRCUIT AHEAD OF ANV SW ITCHING.
3� REFER TO RERECTED CEILING PLAN ON SHEET A240 FOR EXACT
LOCATION AND MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES
W ITHIN THE ENTIRE TENANT SPACE.
� 4� SEE SHEET E110 FOR EQUIPMENT NUMBERSAND KITCHEN
EQUIPMENT ELECTRICAL CONNECTION SCHEDULE ON SHEET E210
FOR MFORMATION ON CONNECTION OF WALK-IN COOLER LIGHTING
SUPPLIED W ITH COOLER.
5 SEESHEETE110FOREQUIPMENTNUMBERSANDKITCHEN
� EQUIPMENTELECTRICALCONNECTIONSCHEDULEONSHEETE210
FOR INFORMATION ON CONNECTION OF HOOD LIGHTING SUPPLIED
W ITH HOOD.
� 6� PROVIDE JUNCTION BOX AND RACEWAV FOR SPEAKERS (BV OTHERS),
BACKTOTERMINALEQUIPMENTATMANAGER'SDESK. COORDINATE
EXACT REQUIREMENTS W ITH G.C.
�� PROVIDEJUNCTIONBOXANDRACEWAVFORSECURITYCAMERAS(BV
OTHERS), BACK TO TERMINAL EQUIPM ENT AT MANAGER'S DESK.
COORDINATE EXACT REQUIREMENTS WITH G.C. INSTALLER TO
VERIFV LME OF SITE IS SUFFlGENT AND REPORT ANV ISSUES TO
BIBIBOP REPRESENTATIVE.
8 � NOT USED.
� 9� PROVIDE LUTRON MAESTRO VACANCV SWITCH.
� 10 � SW ITCH BANK LOCATION. PROVIDE SW ITCHES AS REQUIRED PER
� ENERGVCODEREQUIREMENTSANDLABELEACHSWITCHWITH
LIGHTS THAT THEV CONTROL 8 PANEL CIRCUIT ASSOC WTED W ITH.
COORDINATE EXACT LOCATION W ITH FlNAL EQUIPMENT PLAN PRIOR
TO ROUGH-IN.
� 11 � PROVIDE TORK OR EQUAL 4 CHANNEL ASTRONOMIC DIGTAL TIME
� CLOCKWITHO-2HOURSPRINGWOUNDWERRIDEFORCONTROLOF
INTERIOR LIGHTMG AND SIGNAGE W ITH A 4 POLE CONTACTOR.
�p� PROVIDELIGHTINGINVERTERISOLITEIMI125MODELNO.IMI-1&LC-Vi-
TB FOR EMERGENCV LIGHTMG. COORDINATE EXACT LOCATION PRIOR
TO ROUGH-IN.
13 � THIS LIGHT SHALL BE CONNECTED TO THE EMERGENCV LIGHTING
INVERTER AHEAD OF ALL SW ITCH CONTROLS.
14� NOTUSED.
15 VERIFV IF THERE IS ADEQUATE EXISTING EMERIOR GENERAL
LIGHTING. PROVIDE NEW AS REQUIRED. COORDINATE FIXTURE TYPE
W ITH TENANT AND LANDLORD IF REQUIRED.
i6 � ALL FIXTURE HEADS TO BE REPOSITIONED BV CONTRACTOR AFTER
� CASEW ORK IS INSTALLED. VERIFV FlNAL LOCATION W ITH TENANT'S
REP.
� 1] � EXISTMG FlXTURE TO REMAIN. MAINTAM EXISTMG CONNECTIONS AND
� CONTROLS.
18� PROVIDEPOWERANDFINALCONNECTIONTOINTERIORSIGNAGE.
� COORDINATERWUIREMENTSWITHBIBIBOPANDSIGNAGEVENDOR
PRIOR TO ROUGH-IN. CONTROL VIA TIME CLOCK.
KEY
FIXTURE TVPE
D(2) = 2 TRACK HEAD FIXTURES OF TVPE'Ti'
A NL-+: "NIGHTLIGHT
OLIS-c
EM-c "EMERGENCVLIGHT'
� PANEL/CIRCUITNUMBER-SWITCHLEG
LIGHT FU(TURE
�
�
e/3-a
�
C
— e
3
2
.2. 2 �NL �12�
REH Rl �Xi �
B/ 3 U B/ 3 6/ 3
1¢
B
5
,- ���.. tLtC I KIC
._.� ��4�� _ ��_���
- VY' METAL CONDUIT, PAMT P3. W HERE POSSIBLE, RUN
CABLMG HORIZONTALLV TIGHT BACK TO WALL.
�� BOTTOM OFPERFORATEDMETALARCH�ATQUEUMG�OR
UNISTRUT (PAINTED'P3; AT CONDIM ENT STATION)
�-4" OCTAGONAL JUNCTION BOX WITH BLANKCOVERPLATE.
MOUNT FIXTURE SOCKET WITH KNUCKLE MOUNTED IN CENTER
OFCOVERPLATE PAINTHOUSMGANDJUNCTIONBOXPER
LIGHT FIXTURE SCHEDULE
------- TVPE"K"FIXTURE,SWNELKNUCKLELAMPHOLDERBVTENANT
� - - - - - - 13 WATT LED PAR30 LAMP
;�z��, TYPE "H" FIXTURE MOUNTWG DETAIL
--' NO SCALE
eisx
17
C
BI 5
xz
3I5 �
{I
i� � �
Z 6
C
B/ 5
I
� B/3
e/3-a EM/NL
� 6 � �
2 13
q
0
C
B/ 5
J
B/3-a
�
E
BIS-e
E
BIS-e
� I�\ �
B/ 5 \b
O 2
X2 �
B/5 �18 Bl3-a
� 0
C
- 12
�
6
J
Bl3-a
X2 �
2 B/ 3
GRID
�
X2
B/3 � H H H
- - B/3-g B/3-g B/3-g
J
B/3-a.i6�� �i6 � �i6
EM O
2•13
� E �
6/5-e 6
\ E
Q Q� � i ' BI5-e
II' C
Bl5.. G. Bl5'.- c : C
BI S
�- ' c
'° e o ' o �o �
d
9�b�
Q a I Q ���. �X1 .B/5-tl 6/5�-c
B/ 5 2
F F O O O O O O O O O O O O
B/ 5
' - .._____'
..._____ __— '_ 5 ________—._ _..
xz
� � B/ 5 2
�
Bl5-f
C
e/5-c
D
BIS-d
C
B/5-c
K
Bl 5 - f
D
BIS-d
C
BIS-cK
BI5-f
D
6I5-d
C
B/5-c
��
H
B/3-g
i6 �1
i6 �)B13-9
J
6/3-a
EM
B Z •13 B
B/3-b B/3-b
� I �
6
�B e
B/3-b B/3-b
� �
finn �laniels
A R C H I T E C T S
GRID 21q5 Ford Parkway, SuAe 301
Saint Paul, Minnesota 55116
651.690.5525
.— � � www.finn-daniels.com
� � � 7/� �' 6
A q q (/r�
B/3-b Bl3-b Bl3-b p•,
2 Xi REH 15
� B/3 �.� B/3
6 p
J �
J J 6/3-a �����
B/3-a B/3-a EM � ��J�
O � O • B
6 z ia �
. �—. � Y = , �-� -
B
BIB b � � ' gIB3 b BB -0 �....
i'
, ,. _, .. .., 6 � .
J �
�3 B 6 B/3-a� ..
BB-b B/3-b �
x B/3-a
pB�l3 �
� � � `CY
H H �! H
&l3-g &l3-g � 6� BI3-g
'. 16 � 16 i6.�
H
B 3-G
iG Qv
-08
C/12
CONSULTANT:
DUNHAM �I
DUNHAM
mso ns s .�is��n�noo
M���op ��,M i�ssaoa-isao
r..'.�61p,<65]550 nx61RA6o.1561
..�e tlunpanengrom
ec�an cal a electi cal co sult ng enB ^e=�ing
SEAL/SIGNATURE:
.��pNER �A. �f.,.,
:� :'¢�c.�Ttq�•%!'�;
_'Vi No.PE1180U559 ;�.
STAIE OF
i���
12/ll/2019
� 6
2
�REH
era 15� PROJECT:
...r.�
�`
LIGHT FIXTURE SCHEDULE
ELECTRICAL
FIXTURE LAMPS FIXTURE MANUFACTURER'S SERIES
LETTER FIXTURE STYLE VOLTAGE MOUNTING TYPE MAX VA NUMBER FIXTURE DESCRIPTION NOTES
A 9.5" PENDANT 120 PENDANT LED 10 VA A19 INCORPORATED 9.5" SPHERICAL WHITE PENDANT Wl6' WHITE CORD.
MOUNT BONAIRE P1601 PROVIDE COVER PLATE IF REQUIRED. SUPPLIED WI10W
4000K LED LAMP.
B 14" PENDANT 120 PENDANT LED 10 VA A191NCORPORATED- DECORATIVE PENDANT. SUPPLIED WI10W 4000K LED LAMP.
MOUNT GRAN THERA P302 TO BE INDIVIDUALLY MOUNTED WIJUNCTION BOX AT DECK.
C 6" ROUND DIAMETER 120 RECESSED LED 7.3 VA HALO - RL560WH68401 6" DOWN LIGHT, SO CRI, 5000K, MATTE WHITE BAFFLE, AND
DOWNLIGHT E1700AT HOUSING ALL-PRO 6" HOUSING
D 4" ROUND DIAMETER 120 RECESSED LED 7.3 VA HALO - RL460WH8401 4" DOWN LIGHT, SO CRI, SOOOK, MATTE WHITE BAFFLE, AND
DOWNLIGHT ET400ATSB HOUSING ALL-PRO 4" HOUSING
E 4" ROUND DIAMETER 120 RECESSED LED 9 VA SATCO - 59468 4" LED DIRECTIONAL DOWN LIGHT, GIMBALED, 5000K, AND
DOWNLIGHT 90 DEGREE BEAM SPREAD
F 2X4 LENSED TROFFER 120 RECESSED (3) F32T8 SS VA COOPER - APT332-L735 2'X4' (3) SOOOK LAMP LENSED TROFFER FLUORESCENT
G BRUSHED NICKEL 120 SUSPENDED INTEGRAL 16 KUZCO LIGHTING- 12" DIAMETER BRUSHED NICKEL PENDANT
PENDANT LED PD1712BN
H SURFACE MOUNTED 120 SURFACE LED 13 VA BY BIBIBOP SURFACE MOUNTED DIRECTIONAL LIGHT FIXTURE WITH 2& 3
DIRECTIONAL FIXTURE 4000K LAMP. SEE DETAIL 2IE100 & 3IA600 FOR ADDITIONAL
INFORMATION. PROVIDED AND INSTALLED BY G.C.
J 6" ROUND DIAMETER 120 PENDANT 13W LED 13 VA PROGRESS LIGHTING- LED CYLINDER DOWN LIGHT, 4000K, WHITE FINISH,
PENDANT PAR30 P5741-30 SUPPLIED WITH LAMP. MOUNT BOTTOM AT 9'-0" A.F.F.
K WALL WASH MENU 120 MONOPOINT LED 16 VA SOLAIS - WW 12y-A-35K-CM CANOPY MOUNT WALL WASH MENU LIGHT
LIGHT
REH OUTDOOR 120 SURFACE LED 5.4VA COOPERAPWR1 REMOTEOUTDOOREMERGENCYLIGHT.COORDINATE 1
EMERGENCY MOUNTING HEIGHT WI LOCAL FIRE MARSHAL.
X1 EXITIEMERGENCY 120 SURFACE LED 4 VA COOPER APCH7R LED EXITIEMERGENCY WIBATTERY PACK & POWER TO 1
REMOTE HEAD. COORDINATE MOUNTING HEIGHT WI LOCAL
FIRE MARSHAL
X2 LED EMERGENCY 120 SURFACE LED 4 VA COOPER APEL LED EMERGENCY WI90 MINUTE BATTERY BACKUP. 1
COORDINATE MOUNTING HEIGHT WI LOCAL FIRE MARSHAL.
GENERAL ELECTRICAL NOTES:
A. DESIGNATED LIGHTMG FlXTURE PACKAGE AND ALL REQUIRED ACCESSORIES FOR MOUNTMG AS SPEGFlED SHALL BE PURCHASED AND FURNISHED BV GENERAL CONTRACTOR VIA BIBIBOP'S DESIGNATED
LIGHTING VENDOR. CONTACT 606 BEATTIE - CAPITAL LIGHTING (614) 841-1200.
B. PROVIDE SHATTERPROOF LAMPS OR LENSES IN ALL FOOD ARFAS.
Q EQ SHALL CONFlRM MOUNTMG HEIGHTS OF ALL FlXTURES W ITH ARCHITECT PRIOR TO ROUGH-IN.
D. EC. SHALL COORDINATE DIMENSIONED LOCATIONS OF ALL FIMURES W ITH ARCHITECPS DRAW INGS PRIOR TO ROUGH-IN.
E. PROVIDE BLOCKING IN WALLS, CEILING, AND CASEW ORK AS NECESSARV TO HANG FIXTURES.
F. WHEREPOSSIBLE,ALLKITCHENBBACKOFHOUSELIGHTFIXTURESSHALLHAVESOOOKLAMPSBALLDINMGLIGHTLIXTURESSHALLHAVE4000KLAMPS.
NOTES:
1. PROVIDE WITH MINIMUM 90 MINUTE BATTERV BACK UP.
2 ATQUEUING,MOUNTTOUNDERSIDEOFPERFORATEDMETALARCH&PAMTHOUSING/JUNCTIONBOXPP.
3. ATCONDIMENTSTATION,MOUNTTOUNISTRUTAT11'-0"AF.F.&PAMTHOUSINGJUNCTIONBOX'P3'.
IF VOU HAVEANV QUESTIONS REGARDMG THE
ELECTRICAL PLANS, PLEASE CALL THE
ELECTRICAL DESIGNER.
DESIGNER: CULLENMURTAUGH
PHON EIFAX: 612-465-�681 1612-465-��81
EMAIL'. cullen.murtaugh@tlunhamengcom
. . . • •
asian grill
THE BRIDGES
365 WEST 116TH STREET
SUITE 140
CARMEL, INDIANA 46032
BIBIBOPSTORENO.: TBD
BIBIBOP PO NO: THE BRIDGES
PROIEQ NO.:
DRAW N BV:
CHECKE� 8V'
ISSUES AND REVISIONS:
LL/QIENT REVIEW SET
PERMIT ISSUE
oazo99s-ii9
CM
RM
11262019
12.112019
SHEET TITLE:
LIGHTING PLAN
E100