HomeMy WebLinkAboutP105.0-P210-PLUMBING DETAILSyq. � EXTEND TO ITEMS: E10 E100 E104 WATERFILTER � 3/4 CW SVSTEM (E9) - 3/4"FW-X � o i � � � � � .�� FW-X , EXTEN�TOITEMS- E33 BALLVALVE I E4ZE43 TYPICAL � E10VE102 ���'— TERMINATE DRAINS W ITH AIR GAP ABOVE FUNNEL FLOOR DRAIN MIN. ]'-0"A.F.F. � FLOOR NOTE: SCHEMATIC BASE� ON MANUFACTURER INSTALLATION �ETAIL COOR�INATE INSTALLATION WITH MANUFACTURERAND KITCHEN EpUIPMENT VENDOR. � . FILTERED WATER SCHEMATIC / NOSCALE MiN. za^ rznows s" FlN. RR. LME �� 4 .......\ ` . .....I. a "�`p � 4 �' ,�%� *tl � �" � I '—}i � � s` ,s �. ! � UNDERGROUNDCONDUIT • CON�UITTOBEWATERTIGHTPVCAN�MUSTHAVEASMOOTHINTERIORWITHAMINIMUM INSIDE DIAMETER OF 6". • SLEEVETOHAVELEAK-TIGHTJOINTSANDMUSTHAVEONLVONE�i)24"RADIUSSWEEPBEND AT EACH END. • EXPOSEDENDSOFCONDl11TTOBESTl1BBED-l1PAMINIMl1MOF4"ABOVEFINISHEDFLOOR, CAPPED AND SEALED AT BOTH ENDS DURING CONSTRUCTION. . AFTER�RINKLINESAREINSTALLE�(BVOTHER),OPENEN�SARETOBEFlLLE�AN�SEALE� WATERTIGHT APPROXIMATELV P' TO 4" AT EACH END. • AFTER GAS PIPING IS INSTALLED IN SLEEVE BOTH ENDS SHALL NOT BE SEALED. PVC SLEEVE DETAIL 5 NO SCALE 3 COMP. SINK FURNISHED BV KITCHEN EQUIPMENT SUPPLIER. �� � � �� �.�� 2"VENTONROOFSINK. ' - EXTEND TO VENT MAIN IN CEILING. SEE PLAN. I �. i �� '���-__�-� � TOGREASEWASTE SEE PLAN. -7 , 3-COMP SINK DETAIL NO SCALE GAS PIPE o PENETRATION THRU ROOF � � o :�� NO SCALE finn �laniels A R C H I T E C T S 2145 Ford Parkway, SuAe 301 Saint Paul, Minnesota 55116 651.690.5525 www.fin n-dan iels.com CONSULTANT: DUNHAM �I DUNHAM mso ns s ..is .noo M �o p M � � ssaoa- s o ..� 6 H 65 550 r. ti 2 6. S e a n, y m cn i i mcaic it g nBineenng SEAL/SIGNATURE: W.11100108 : STRTEOi � 12/ll/2019 PROJECT: ...r.� �` . . . • • asian grill THE BRIDGES 365 WEST 116TH STREET SUITE 140 CARMEL, INDIANA 46032 BIBIBOPSTORENO.: TBD BIBIBOP PO NO: THE BRIDGES UNION AT DRAIN PAN CONNECTION. INSULATION AROUN� UNION SHALL BE REMOVABLE. TVPICAL OF FREEZER ANDCOOLERINSTALL COOLER��'� � EVAP.COIL SLOPE GONDENSATE DRAIN IN '� � COOLER 1/2" PER FOOT. SECURE PIPE � � TOOOOLERWALLWITH9PAOMG � ��� BRACKETS. / �'. PENETRATION THRU ��tif'�'J COOLER PARTITION. �� , ��'��..�i TRAP LOCATED IN ADJACENT SPACE CO OUTSIDE OF FREEZER ,r SECURE PIPES TO WALL EXPOSE� W ITH SPACING BRACKETS. INDIRECT CONNECTION W ITH AIR GAP PERLOCALCODE FLOOR DRAIN wiFUNNE� .:. �\�. SLOPE CONDENSATE DRAIN IN COOLER il2" PER FOOT. SECURE PIPES TO COOLER W ALL W ITH SPACMG BRACKETS. � TEMPERED WA THERMOSTATI( MIXING VALVE HOT WA WATER NOTE: SET TEMPERED WATER TEMPERATl1RE TO 110 DEG F MAX. THERMOSTATIC MIXING VALVE DETAIL 2 'Norroscn�E EpUIPMENT GAS CONNECTION, VERIFV SIZE AND LOCATION W ITH KITCHEN EpUIPMENTPLANS �UI�UIY.<Nyy�Ri�i]Y ELBOW BV MECH. CONTRACTOR. FACE OF BUILDMG WALL KITCHEN � ' SHUT OFF VALVE OFFSET EpUIPMENT -��\ BVMECH CONTRACTOR ' I —WALL � � ��qUICKDISCONNECTHOSE & FITTMG SUPPLIED BV � ��- UTILITVOUT � �� K.ESUPPLIER,INSTALLED OF WALL B1'MEGH GONTR. � ��1 � � COORDINATE WALL REINFORCMG KITCHEN �L���VJ � W/GENERALCONTRACTOR EpUIPMENT FINISHED FLOOR ., _ RESTRAINMG CABLE BV F.S.E.C. PLAN VIEW SIDE VIEW NOTE'. IF UTILITV INLET IS NOT AT HEIGHT SHOW N, MECHAN ICAL CONTRACTOR TO PROVIDE PIPING W ITH ELBOW S TO RAISE MLET. GAS PIPING DETAIL — AT KITCHEN EQUIPMENT ! 3 Nos�A�E DISTANCE BETWEEN COMPARTMENT DRAINS SHALL NOT EXCEED 30" O.C. �— — I CHEMICAL �ISPENSERASSEMBLIES SHALL MEET I I THE REpUIREMENTS OF ASSE 1055 W ITH A I PRESSUREBLEEDINGDEVICE(SIDEKICK)8A I BACKFLOW PREVENTER. NO EXCEPTION. WVE � T T CONNECTORS ARE NOT EpUAL. CHEMICAL DISPENSER BVOTHERS. SERVICESMK FAUGET �''s �i � ��''� ��.i ___ 3l4"WATTSN9-CDHOSE '�-pRESSUREBLEE�MG�EVICEECOLAB CONNECTION BACKFLOW SIDEKICK. NO EXCEPTIONS. PREVENTER. ASSE1052 OR EpUAL. (� CHEMICAL DISPENSER VACUUM BREAKER DETAIL ' " - NO SCALE GRATE (SEE SCHEDULE FOR SPECIFlCATION-GRATE SHOW N FOR REFERENC COORDINATE PLACEMENT WITH KITCHEN EpUIPMENT UNIT CONNECTION SRE. FIELD VERIFV W ITH EpUIPMENT FURNISHED BV KITCHEN EpUIPMENT CONTR(KEC) COPPER CONDENSATE DRAIN PIPE IN COOLER W RAPPED W ITH HEAT TRACE TAPE AND INSULATION PER MANUFACTURER'S RECOMMENDATIONS. EVAPORATOR CONDENSATE DRAIN DETAIL n RELEASED FOR CONSTRACTIDN Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y�,:�v��� �'�a;,v��tiw� � � DATE: OZ�1 H�ZO � r �� ��� 80�V-SMOOTHINTERIOR PROPERLV SEAL FLOOR SMK AS WALL SURFACE REQUIRED BV LOGAL HEALTH DEPT. �, YBaTTOM REGULATIONS&SUCHTHATGRATECAN DOME BE EASILV REMOVE� FOR REpUIRE� HUB 'FLOOR SMKSHALL CLEANINGS. . OURET � STRAMER gEALIGNEDTO FLOOR TILE FINISH, FLOORSWKCOVERSHALL AIRGAPPER WHEREAPPLICABLE BE FLUSH W ITH FINISH LOCAL CO�E �--.�� FLOORMATERIALELEVATE .�:�DRAM CUTANDREMOVEEXISTING IF REpUIRE� 8V AHJ LME CONCRETE SLAB. � � - -- ��, _ _ i FlNISHED TRE ROOF FlNISHEDCONCFETEROOF � �- \� r} � (WHEREINDICATED) (WHEREIN�IOATE�) ��11 `- � f3 � . t`�' � GUTSLABBAGKTOAGGEPT �/�� ' � pqNFOR FLOORMEMBRHNE . FORMING 11SE THRII PENETRATION �`� FORM 8 POUR IN FILL WITH FIRE STOP SVSTEM. AS HVDRAULIC CEMENT TO REQUIRED BV CODE . PRESERVE FLOOR RATMG. - FLOOR SINK DETAIL 1 0 I NO SCALE PLUMBMG CONTR SHALL INSTALL DRAINVALVESFURNISHEDBV � KITCHENEpUIPMENTSUPPLIER .. INDIRECT CONNECTION TO FLOOR SINK VIAAIR GAP. TERMINATE SINK DRAIN A MIN IMUM DISTANCE FROM FLOOR SINK PER CODE. TRAPPEDANDVENTED FLOOR SINK COORDINATE ALL ROOF SUPPORTS WITH LAN�LOR� AND APPROVED ROOFING CONTRACTOR AS REpUIRED. CLAMP PIPE TO STEEL CHANNEL. GAS PIPE/ELECTRICAL CONDUIT/REFRIG. PIPMGI CONDENSATE PIPMGMITCHEN EpUIPMENTCONDENSERS. RUBBER SUPPORT BLOCK W ITH GALVANIZEDSTEELCHANNEL. REFER TO SPECIFICATION SECTIQN � HANGERSANDSUPPORTSFOR � APPROVEDMANUFACTURERS �" _ _ PLUMBINGCONTRACTORSHALLINSTALL � � RISERSUPPORTSASNECESSARVFORGAS PIPE/EpUIPMENTSUPPORTSSHALLBE � PIPWGTOBELEVELACROSSROOF. C-PORT (C10 FOR PIPING & C40 FOR � - SPACE 5 O.C. EQUIPMENT) AS MANUFACTURED BV QEARLMETECHNOLOGIES-C-PORT^ — — _ ROOFSURFACE ROOF PIPE/EQUIPMENT SUPPORT DETAIL 11 1 No s�A�E - HANGER ROD . NUT (TOP & BOTTOM) - WASHER�TOPBBOTTOM) d��� —HEAWDUTVCLEVISHANGER �� � T� �� , INSULATION '\� . PIPE {. -� INSULATION PROTECTNE SHEETMETAL SHIELD - THREADED ROD CUT TO LENGTH � .�� ..� CLEVISTVPEPIPEHANGER � I �GARRIERPIPE l � — INSULATION r =,;; �F , _ —SHIELDFORINSULATION PIPE HANGER DETAIL 4 ! No s�A�E COORDINATE ALL ROOF EXTEND PIPE ABOVE ROOF PENETRATIONS WITH ASREQUIREDFORTALL �ANDLORDAPPROVED CONEROOFPENETRATION ROOFMGCONTRACTOR. BOOT SHUTOFFVALVE, � �� SEE PLANS- 18 � � ROOF � � � WATERTIGHT ROOF � � � � � � � � � � � PENETRATION BOOT BV I. � ... GAS PIPE SEE DETAIL 4IP210 FOR PIPE SEE DETAIL 11IP210 FOR SUPPORT FROM STRUCTURE `� � ROOFTOP SUPPORT — PROIEQ NO.: DRAW N BV: CHECKEO 8V' ISSUES AND REVISIONS: LL/QIENT REVIEW SET PERMIT ISSUE 0420995-119 TA8 GMS 11262019 12.112019 SHEET TITLE: PLUMBING DETAILS P210