Loading...
HomeMy WebLinkAboutP106.0-P300-PLUMBING SPECIFICATIONSfinn �laniels A R C H I T E C T S RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y�,:�v��� �'�a;,v��tiw� � � DATE: OZ�1 H�ZO DIVISION 15000 - MECHANICAL SECTION 15001 - BASIC MECHANICAL RE�UIREMENTS A. GENERAL CONDITIONS 1. THEDRAWMGSANDGENERALCONDITIONS,INCLUDMGSUPPLEMENTARVGENERALCONDITIONS SHALL APPLV TO ALL W ORK IN DIVISION 1 W00. 2. THECONTRHCTORFORTHISDIVISIONSHALLREVIEWTHEDRAWINGSANDACCOMPANVING SPECIFICATIONS, EXAM INE THE SITE, CHECK AS TO THE MEANS OF MAKING CONNECTIONS TO SERVICES,ANDSHALLBECOMEFAMILIARWITHALL THEEXISTMGCONDITIONSAND LIMITATIONSBEFORESUBMITTINGAPROPOSAL. ANVAPPARENTVARIANCESOFTHEPLAN OR SPECIFICATION FROM THE EXISTING CONDITIONS AT THE SITE SHALL BE CALLED TO THE ATTENTION OFTHE ENGINEER DURMGTHE 61D PERIOD SO THAT CLARIFICATION CAN 6E MADE BV ADDENDUM. ITEMS KNOWN TO BE INCONSISTENT WITH THE BID DOCUMENTS INTENT MUST BE LISTED AND pUALIFIED ON THE CONTRACTORS BID FORM. NO EXTRAS W ILL BE ALLOW ED BECAUSE OF THE CONTRACTORS MISUNDERSTANDMG AS TO THE AMOUNT OF WORK INVOLVED OR HIS LACK OF KNOW LEDGE OF ANV SITE CONDITIONS W HICH MAV AFFECT HIS W ORK. 3. COORDINATIONOFSCHEDULINGFORCOMPLETIONANDALLINSPECTIONSOFTHEIRWORKAND WORK OF SU6CONTRACTORS IS THE RESPONSI6ILITV OF THIS CONTRACTOR. 4. BEFORESUBMITTMGAPROPOSALONTHEWORKCONTEMPLATEDONTHESEDRAWMGSAND ACCOMPANVING SPECIFICATIONS, EACH BIDDER SHALL EXAMINE THE SITE, CHECK AS TO THE MEANSOFMAKMGCONNECTIONSTOSERVICES, ANDSHALLBECOMEFAMILIARWITHALL THE EXISTMG CONDITIONS AND LIMITATIONS. MECHANICAL EQUIPMENT AND SVSTEMS SHOW N AS EXISTING ON THE PLANS HAVE BEEN BASED ON EXISTING DRAW INGS. NO EXTRAS W ILL BE ALLOW ED 6ECAUSE OF THE CONTRACTOR'S M ISUNDERSTANDMG AS TO THE AMOUNT OF W ORK INVOLVED OR HIS LACK OF KNO W LEDGE OF ANV SITE CONDITIONS W HICH MAV AFFECT HIS W ORK. ANY APPARENT VARIANCE OF THE PLAN OR SPEQFICATION FROM EXISTING CONDITIONS AT THE SITE SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER DURING THE BID PERIOD SO CLARIFlCATION CAN BE MADE BV ADDENDUM. SECTION 15002-GENERAL REQUIREMENTS 1. WORKTOBEACCOMPLISHEDONTHESEDRAWMGSANDSPECIFICATIONSINCLUDESFURNISHMG ALL LABOR, MATERIAL, EpUIPMENT AND SERVICES FOR THE COMPLETION OF ALL MECHANICAL WORK. ALL MECHANICAL WORK UNLESS NOTED TO BE SPECIFICALLV BV THE LANDLORD IS THE RESPONSIBILITV OF TH IS CONTRACTOR. 2. THISCONTRACTORANDTHEIRSUBCONTRACTORSSHALLWORKCLOSELVWITHTHETENANT PROJECT MANAGER FOR COORDINATION OF TRADES AND COMPLETION OF THE PROJECT. 3. PLANSANDSPECIFlCATIONSARECOMPLEMENTARVANDWHATISCALLEDFORMEITHERONE SHALLBEASBINDINGASIFCALLEDFORINBOTH. ANVITEMORLABORTHATISNECESSARV TO COMPLETETHE WORKAND IS TYPICALLV INCLUDED IN SIMILAR WORK SCOPE SHALL BE FURNISHED AND INSTALLED AS PART OF THE CONTRACT W HETHER OR NOT IT IS SHO W N ON THE PLANS OR IN THE SPEQFICATIONS. 4. WHENTHEINCLUDEDDRAWINGSAND/ORSPECIFICATIONSCALLOFITEMSWHICHEXCEEDTHE LANDLORDS TENANT CRITERIA OR E%CEED CODE, IT'S THE RESPONSI8ILITV OF THE CONTRACTOR TO INSTALL THE MORE STRINGENT REpUIREMENTS NOTED ON THE PLANS ANDIOR SPECIFICATIONS. IF THE PLANS AND SPECIFICATIONS HAVE DISCREPANCIES BETW EEN THEM, THE CONTRACTOR SHALL ASSUME IN THEIR BID THAT THE MORE STRMGENT ITEM IS REpUIRED AT NO ADDITIONAL COST. 5. ALLPIPING,DUCTWORKANDEpUIPMENTSHALLBEFURNISHEDANDINSTALLEDTOPRESENTA NEAT AND CLEAN APPEARANCE USMG GOOD CONSTRUCTION PRACTICES. EpUIPMENT SHALL 6E INSTALLEDFORPROPERACCESSTO OPERATE,SERVICEANDMAINTAINTHEEQUIPMENTWITHOUT HAVINGTOMOVEOTHEREpUIPMENTFORACCE55. ANVMECHANICALEpUIPMENT(OREXISTING EQUIPMENT TO REMAIN) THAT REQUIRES ACCESS PANELS SHALL HAVE THOSE PANELS FU RNISHED AND INSTALLED BV THE MECHANICAL CONTRHCTOR. 6. UNLESS SPEQFICALLV NOTED ON THE PLANSISPEQFICATIONS ALL MATERIALSAND EpUIPMENT SHALL 6E NEW AND 6EST pUALITV TO CONFORM TO THE REpUIREMENTS OF THE LANDLORDS TENANT CRITERIA, LOCAL AND STATE CODES GOVERNMG THE WORK INVOLVED AND BE MADE BV NATIONALLY RECOGNIZED MANUFACTURES W ITH UL LISTINGS AND LABELS. SECTION 15003-CODES 1. ALLWORKSHALLBEINSTALLEDINCONFORMITVOFTHELANDLORDSTENANTCRITERIA,AND APPLICABLE LOCAL CODES AND ORDINANCES AND STATE STATUTES. ALL REQUIREMENTS OF THE CURRENTPLUMBMGCODES,HEATMG ANDVENTILATIONCODES,HEALTHANDSAFETI' CODES, N FPA CODES AND ENERGY CODES MUST BE MET. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MQUIRE INTO AN D COMPLV W ITH ALL LOCAL ORDINANCES AND INCLUDE ANV ADDITIONAL ITEMS NOT NOTED IN THE PLANS/SPECIFlCATIONS IN THEIR BID. ANV CHANGESTO THE MECHANICAL SVSTEM AS REQUIRED BV LOCAL, STATE OR TENANT CRITERIA THAT ARE NOT QUALIFIED ON THE CONTRACTORS BID FORM ARE ASSU MED TO BE INCLUDED IN THE ORIGINAL BID AND ADDITIONAL COSTS W ILL NOT BE DUE TO COMPLETE THOSE ITEMS AFTER THE CONTRACT IS ISSUED. SECTION 15004 - LICENSES, PERMITS, INSPECTIONS & FEES 1. THISCONTRHCTORISRESPONSIBLEFORALLFEES,CHARGESANDOBLIGATIONSFOROBTAINING PERMITS AND INSPECTIONS FOR PLUMBING, HEATING AND VENTILATION AN D FIRE EXTINGUISHING WORK. 2. ALL CERTIFlCATES OF INSPECTION AND FlNAL INSPECTIONS SHALL BE TURNED OVER TO THE TENANT'S PROJECT MANAGER AT THE COMPLETION OF THE PROJECT. SECTION 15005 - TRADE NAMES, MANU FACTURERS AND SHOP DRAW MGS 1. IN ANV CASE W HERE A SPECIFIC NAME OF EpUIPMENT OR MATERIAL IS MENTIONED ON THE DRAW INGS OR SPEC IFICATIONS THE EXACT EQUIPMENT SHALL 8E USED FOR THE BASE 81D. EQUIPMENT OF EQUAL GRADE AND QUALITV W ILL BE SUBJECT TO PRIOR APPROVAL BV THE TENANT'S PROJECT MANAGER AND THE ENGMEER IN W RITING THRU THE SHOP DRHW ING SU6MITTAL PROCESS. ANV EpUIPMENT INSTALLED WITHOUT WRITTEN APPROVAL WILL 6E CHANGED OUT TO THE SPECIFlED E�UIPMENT AT THE CONTRACTORS EXPENSE. 2. MECHANICALCONTRACTORSHALLSUBMIT3COPIESOFSHOPDRAWINGSTOTHETENANT'S PROJECT MANAGER FOR APPROVAL IF APPROVED, COPIES W ILL BE STAMPED "NO EXCEPTIONS" OR "APPROVED AS NOTED" AND W ILL BE RETU RNED TO THE CONTRACTOR. IF NOTATIONS AND MARKS INDICATE THAT REVISED INFORMATION IS REpUIRED, THEN CORRECTED INFORMATION SHALL BE SUBMITTED. SECTION 15006 - GUARHNTEE 1. THISCONTRACTORSHALLASSUMERESPONSIBILITVFORANDDEFECTSWHICHMAVDEVELOPIN ANV PART OF THE SVSTEMS CAUSED BV FAULTY WORKMANSHIP, MATERIAL OR E�UIPMENT, AND AGREES TO REPLACE ANY SUCH FAULTY W ORKMANSHIP, MATERIAL OR EpUIPMENT DURING A PERIOD OF 12 MONTHS FROM THE DATE OF FINAL ACCEPTANCE W ITHOUT ANV COST TO THE OWNER. ANV EXTENDED WARRANTIES (LONGER THAN 12 MONTHS) FOR EpUIPMENT W ILL 6E NOTED ON THE SCHEDULES, PLANS OR SPECIFlCATIONS. 2 EACHPIECEOFEQUIPMENTFURNISHEDBVTHECONTRACTORSHALLHAVEAI2MONTH WARRANTV FOR MATERIAL AND LABOR AT STARTS UPON THE DATE OF FlNAL ACCEPTANCE AS DESIGNATED BV THE TENANT'S PROJECT MANAGER. ALL COSTS FOR THE WARRHNiY (MATERIAL AND LABOR) SHALL BE INCLUDED IN THE ORIGINAL BID. SECTION 15001- RECORD DRHW INGS 1. THIS CONTRACTOR SHALL MAMTAIN AT THE JOB SITE A SET OF DRAW INGS TO BE USED SPECIFICALLV FOR RECORDWG CHANGES FROM THE CONTRACT DOCUMENTS. THE INFORMATION SUCH AS VALVES, DUCT AND PIPE DEVIATIONSSHOULD BE DIMENSIONED FROM EASILV RECOGNIZABLE REFERENCE POINTS INDICATING BOTH HORIZONTAL AND VERTICAL DISTANCES. 2. THECONTRACTORSHALLSUBMITAFINALSIGNEDSETOFASBWLTDRAWINGSTOTHETENANTS PROJECT MANAGER AT THE COMPLETION OF THE PROJECT. 3. THECONTRACTORSHALLSUBMITTOTHETENANTSPROJECTMANAGERATTHEENDOFTHE PROJECT (2) COMPLETE HARD HOUND SET OF CATALOG DATA, MANUFACTURES LITERATURE, DETAIL MANUALS COVERMG THE OPERATION AND MAIMENANCE OF ALL W UIPMENT SPECIFlED. SECTION 15008-DISCREPANCIES IN DOCUMENTS 1. THEDRAWMGSOFPIPMGANDDUCTWORKSVSTEMSSHALLBEINSTALLEDSUBSTANTIALLVAS SHOWNONTHEPLANS. THEEXACTPOSITIONOFEACHANDEVERVPIPE,DUCT,OFFSETAND TRANSITION CANNOT BE GIVEN BV SCALMG THE DRAW WGS BUT SHALL IN EVERV CASE BE PLACED SO AS TO AVOID INTERFERENCE W ITH OTHER W ORK. ALL NECESSARV CHANGES IN THE LOCATION OF PIPE OR DUCTWORK FOR ITS PROPER INSTALLATION AND TO AVOID CONFLICT W ITH OTHER TRADES SHALL BE DONE BV THE CONTRACTOR AT NO ADDITIONAL CHARGE. SECTION 15009 DEMOLITION 1. THISCONTRACTORSHALLBERESPONSBLEFORTHECOORDINATIONOFTHEDEMOLITIONOF EXISTMG WORK AND THE DEMOLITION PROVIDED BV THE GENERAL CONTRACTOR. COORDINATE W ITH THE GENERHL CONTRACTOR ANV EXISTING EpU IPMENT REpUIRED TO BE LEFT INTACT. 2 EACHCONTRACTORSHALLVERIFVSCOPEOFWORKWITHTHEGENERALCONTRACTORFORTHE REMOVAL OFALL EXISTMG FlRE PROTECTION, PLUMBMG FlXTURES, PIPMG, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED RW F CURBS NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLV NOTED OTHERW ISE. 3. CONTRACTORMUSTVERIFYWITHTHELANDLORDALLPRESUMEDABANDONEDEQUIPMENT,PIPES, DUCPNORK AND EpU IPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST 6E REMOVEDAND ROOF/JJALLffL00R PATCHEDIREPAIRED TO MATCH EXISTING STRUCTURE. 4. EXISTINGABANDONEDPIPES,DUCTS,OREpUIPMENTINTHEFLOOR,EMBEDDEDINCONCRETE,OR OTHERW ISE INACCESSIBLE ARE TO 8E CUT OFF AND SEALED BELOW OR W ITHIN FLOOR OR W ALL LEVEL W HEN THEV ARE NOT TO BE REUSED IN THIS PROJECT. 5. IF REQUIRED BV LANDLORD OR CODES, ABANDONED PIPING AND/OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION W ITH THE GENERAL CONTRACTOR AND TENANT PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BV THE GENERALCONTRACTORANDTENANT. SECTION 15010 - CUTTMG AND PATCHMG L THISCONTRACTORSHALLPROVIDEALLCUTTINGANDPATCHINGREpUIREDFORTHE INSTALLATION OF HIS EpUIPMENT IN THE 6WLDMG WALLS, PARTITIONS, FLOORS, CEILMGS, ETC., UNLE55 OTHERW ISE NOTED. ALL CUTTING AND PATCHING SHALL BE SUBJECT TO THE DIRECTION OF THE LANDLORD, ARCHITECT OR ENG W EER. 2. THISCONTRACTORSHALLNOTENDANGERTHESTABILITVOFTHESTRUCTUREBVCUTTMG, DIGGMGOROTHERWISEALTERMGTHESTRUCTUREANDSHALLNOTAT ANVTIMECUTOR ALTER W ORK OF ANV OTHER CONTRACTOR. 3. PATCHINGOFWALLS,FLOORSANDROOFSHALLBEOFSAMEMATERIALANDWORKMANSHIPOF THE SU RROUNDMG MATERIAL W ITH FINISHED SURFACE APPEARMG THE SAME AS THE SURROUNDINGAREAS. ALL PATCHING SHALL BE PERFORMED BY WORKMEN SKILLED M THAT PARTICULAR TRADE. 4. DAMAGE CAUSED BV THE CONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR IN A SU ITABLE MANNER ACCEPTABLE TO THE LANDLORD AND TENANT'S PROJECT MANAGERS. SECTION 15011 -SLEEVES 1. THISCONTRACTORSHALLINSTALLSLEEVESINCONNECTIONWITHALLPIPESPASSINGTHROUGH ALL W ALLS, PARTITIONS AND FLOORS. SLEEVES SHALL EXTEND THROUGH FULL TH ICKNESS OF W ALLS AND FLOORS AND SHALL BE CUT FLUSH W ITH THE FINISHED SURFACES. SLEEVES IN SLABS SHALL BE CUT Y' ABOVE THE FLOOR SURFACE. 2 ALLSLEEVESSHALL8E22GAUGEGALVANIZEDSTEELMINIMUMFINISHEDWITHASMOOTHEDGE ANDPROPERLVSUPPORTED. 3. COREDRILLINGFLOORSANDWALLSMUSTBECOORDINATEDWITHTHELANDLORDANDTHE TENANT'S PROJECT MANAGER. 4. THISCONTRACTORSHALLFURNISHANDINSTALLFlRESTOPPMGATALLPENETRATIONSTHRU RATED FLOORS TO MAINTAIN THE FIRE RATING. 3M FIRE BARRIER SVSTEMS, FLAME SAFE FIRE RETARDANT SVSTEMS, DOW CORNMG, SPECSEAL OR EpUAL THE CONTRACTOR MUST PRESENT UL LISTMG DATA SHEETS TO THE TENANT'S PROJECT MANAGER AND LANDLORD TO SHOW THAT THE PENETRATIONS MAINTAIN THE FIRE RATING. SECTION 15012 - HANGERS 1. FURNISHANDINSTALLBRACKETS,BRHCESORREINFORQNGANGLESASREpUIREDFORALL PARTITIONS NOT SUFFICIENT IN THEMSELVES TO SUPPORT PLUM6MG FIXTURES OR OTHER EQUIPMENT. 2. PIPING SHALL BE SUSPENDED FROM CONSTRUCTION ABOVE WITH ANGLE IRON, CLAMPS, UNISTRUT, OR HANGER RODS. NO PIPING SHALL BE HUNG FROM OTHER PIPING EXISTING OR NEW. CONTRACTOR SHALL COORDINATE W ITH LANDLORD CRITERIA AND ALL CODES. 3. ALLPIPESWHICHARESPEQFlEDTOBEINSULATEDSHALLHAVEPREFABRICATEDINSULATED METAL SADDLES SIZED FORTHE INSULATION THICKNESSAND CONTINUOUS INSULATION THROUGH THE HANGER. ALL DISSIMILAR METALS MUST BE SEPARATED W ITH DIELECTRIC MATERIAL. DIVISION 15400-PLUMBING SECTION 15401 -SUMMARV OF WORK A. THISCONTRACTORSHALLFURNISH,INSTALLANDTESTALLNECESSARVMATERIALFORACOMPLETE OPERATMG PLUMBMG SVSTEM. IT IS THE RESPONSIBILITV OF THE CONTRACTOR TO DETERMINE THE LOCATION OF THE EXISTING WATER, VENT AND DRAIN LMESTO MAKE CONNECTIONS IN ORDERTO COMPLETE THE W ORK AS SHO W N ON THE PLANS. ALL MATERIAL SHALL BE NEW AND SHALL BE INSTALLED FOR PROPER ACCESS FOR SERVMGS. ANV ACCESS PANELS NECESSARV FOR SERVMG EQUIPMENT SHALL BE FURNISHED AND INSTALLED BV THIS CONTRHCTOR. SECTION 15402 MATERIALS A. THE PLUMBING FlXTURE SCHEDULE ISSHOWN ON PLANS. ALL EpUIPMENT SHALL BE INSTALLED ACCORDING TO THE MANUFACTURES INSTALLATION INSTRUCTIONS. B. SANITARV WASTEAND VENT PIPING 1. ALLWASTEDRAINAGEPIPMGSERVMGCORROSIVHACIDICENVIRONMENTSINCLUDMGBUTNOT LIMITED TO KITCHEN, BAR, SERVICE STATIONS, ETC. SHALL BE CONSTRUCTED OF ACID RESISTANT PIPE AND FITTINGS THAT MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATMGS OF 25/50. ORION PLENUM PLUS OR SIMILAR AS APPROVED BV LANDLORD AND LOCAL AUTHORITV HAVING JURISDICTION. 2 ALLOTHERWASTE,VENTANDDRAINPIPMGSHALL6ESERVICEWEIGHTCASTIRON. NOHU6 CONNECTIONSSHALLBEUSEDABOVEGROUND. HUBANDSPIGOTCONNECTIONSSHALLBEUSED BELOW GRADE. GALVANRED STEEL VENT PIPING MAY BE USED ABOVE GRADE ON Y' OR SMALLER PIPE. NO PVC PIPING W ILL BE ALLOW ED. 3. ALL WASTE PIPMG LOCATED IN THE CEILMG OF TENANT SPACES BELOW SHALL BE INSULATED W ITH 1" INSULATION W RHP AND ASJ COVERING FOR SOUND INSULATION. 4. CONDENSATEPIPINGSHALLBETVPE"C'HARDDRAWNCOPPERINSULATECONDENSATEPIPMG W ITH 1" INSULATION W RAP AND ASJ COVERING. C. GREASE WASTE PIPING 1. ALL GREASE WASTE DRAINAGE PIPING SHALL BE CONSTRUCTED OF ACID RESISTANT PIPE AND FlTTMGS THAT MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATMGS OF 25/50. ORION PLENUM PLUS OR SIMILAR AS APPROVED BY LAN DLORD AND LOCAL AUTHORITY HAVING JURISDICTION. 2 ALL WASTE PIPMG LOCATED IN THE CEILWG OF TENANT SPACES 6ELOW SHALL 6E INSULATED W ITH 1" INSULATION W RHP AND ASJ COVERING FOR SOUND INSULATION. D. POTABLE WATER PIPING 1. ALLUNDERSLABDOMESTICWATERPIPMGSHALLBECPVCORPEX.IFNOTALLOWEDBVLOCAL JURISDICTION, PROVIDE iYPE'K' COPPER PIPING W ITH MINIMAL JOINTS. 2. ALLABOVEGRADEPIPINGSHALLBETVPE'L'HARDDRAWNCOPPERTUBEWITHSWEATJOINTS.ALL PIPMG CONNECTIONS WITH DISSIMILAR METALS SHALL HAVE D4ELECTRIC CONNECTIONS. 3. INSULATE ALL HOT WATER, COLD WATER AN D INTERIOR CONDENSATE PIPING W ITH 1" THICK (K=0 23 @]5 F) PIPE INSULATION. INSULATION TO BE AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPRFAD AND SMOKE DEVELOPED RATMGS. OW ENS-CORN MG OR EQUAL. 4. TRUEBROMODEL102W WHITEINSULATIONKITSHALLBEINSTALLEDONALLTRHPSANDSUPPLV LMES BELOW LAVATORIES TO MEET ADA. 5. SIOUXCHIEF650SERIESALLSTAWLESSSTEEL,ORJR.SMITHHVDROTROLSSHOCKABSORBERS SHALL BE INSTALLED IN BOTH HOT AND COLD LMES OF PIPMG SVSTEM TO PREVENT NOISE AND DAMAGE DUE TO W ATER SHOCK ABSORBERS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURES INSTALLATION INSTRUCTIONS. 6. THE CONTRACTOR SHALL PROVIDE BALL VALVES IN THE SUPPLV PIPMG TO EVERV FlXTURE FOR SERVIQNG. CONTRHCTORSHALLFURNISHANDINSTALLACCESSPANELSWHERENECESSARVFOR PROPER SERVICMG. 1. MAXIMUMPIPESUPPORTSPACMGOFSFEET.CONTRACTORSHALLPROVIDENECESSARVSEISMIC BRHCINGWHEREREpUIREDBVLANDLORD CRITERIA,CODEANDLOCALAUTHORITIES. 8. THE CONTRACTOR SHALL STERILIZE NEW AND EXISTING WATER SVSTEM AS REpUIRED BV LOCAL CODES. CONTRACTOR SHALL INSTALL ANV ADDITIONAL SERVICE VALVES NEEDED IN ORDER TO ISOLATE SVSTEM FOR STERILRING THE W ATER SVSTEM. 9. CONTRACTORSHALLPROVIDECHROMEPLATEDESCUTCHEONSATALLEXPOSEDPIPE PENETRATIONS IN FINISHED SPACES. 10. FLOOR DRAINS W ITH DEEP SEAL TRAPS REpUIRED. INSTALL TRAP PRIMERS IN ALL FLOOR DRAINS. LOCATE CLEAN-OUTS IN WALLSAND FLOORS AS REpUIRED TO MEET LOCAL CODES. 11. CONTRACTOR SHALL PERFORM ALL PIPMG PRESSUREILEAK TESTS BE AS REpUIRED 6V LOCAL CODES. ALL ROOF FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. 12. ANV ROOF WORK MUST BE DONE BV THE LANDLORD'SAPPROVED ROOFMG CONTRACTOR IN ORDER TO MAINTAIN THE ROOF WARRANTEE ALL COSTS FOR ROOF WORK MUST BE INCLUDED IN THE BID. 13. CONTRACTORSHALL FURNISH AND INSTALL WATER METERAND REMOTE READER PER LANDLORD'S CRITERIA OR AS REQU IRED BV LOCAL UTILITIES REQUIREMENTS. E. GASPIPWG L FURNISH AND INSTALL A FUNCTIONAL GAS PIPMG SVSTEM WITH NECESSARV VALVES, FlTTMGS, UNIONS, DIRT LEGS, REGULATORS, METER$ ETG REFER TO PLANS FOR EXACT REpUIREMENTS. 2 GAS PIPE SHALL HE SCHEDULE 40 HLACK STEEL W ITH MALLEAHLE THREADED FITTMGS FOR P' AND SMALLER,ANDWITHWELDEDJOINTS FOR2-1/2"ANDLARGER. 3. PROVIDEASHUT-0FFVALVE,6"DIRTLEG,ANDUNIONATEACHEpUIPMENTCONNECTION. 4. PROVIDELANDLORDAPPROVEDPIPINGSUPPORTSEVERV5FEETORASREpUIREDBVLANDLORD OR LOCAL AUTHORITV HAVMG JURISDICTION, W H ICHEVER IS MORE STRMGENT. 5. PAINT AND PRIME ALL EXPOSED GAS PIPING ON ROOF & EXTERIOR OF BUILDING W ITH RUST-INHIBITING PAINT. COORDINATE COLOR REpUIREMENTS W ITH LANDLORD. 6. TESTWGANDPURGMGOFGASPIPMGSHALL6EDONEPERTHEREpUIREMENTSOFTHELOCAL GAS COMPANV, LOCAL CODES, AND APPLICABLE NFPA 54 CODES. ]. CONTACTANDCOORDINATEGASSERVICEANDMETERREpUIREMENTSWITHTHELOCALGAS COMPANV AND THE MALCS OPERATIONS MANAGER PRIOR TO 81D. INCLUDE INSTALLATION OF VALVES, FlTTINGS, UNIONS, DIRT LEGS, REGULATORS, METERS, ETG COSTS IN BID. PRIOR TO 61D, THE CONTRACTOR SHALL REVIEW THE MECHAN ICAL, ELECTRICAL AND KITCHEN EQUIPMENT DRAW INGS. THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL RELEVANT W ORK IN THE ENTIRE SET OF DOCUMENTS AND REPORT ALL DISCREPANCIES BETW EEN THESE DRAW INGS TO THE ENGMEER PRIOR TO BIDDING FOR CLARIFlCATION. IF DISCREPANCIES REMAIN UNRESOLVED DUE TO A SHORT TIME FRAME, THE CONTRACTOR SHALL INCLUDE THE MOST W ORK AND THE HIGHER COSTS IN THE BID. SOLUTIONS TO UNREPORTED DISCREPANCIES W ILL BE DETERMINED HV THE ARCHITECTIENGINEER, W ITH NO ADDITIONAL COMPENSATION DUE TO THE CONTRACTOR. 2145 Ford Parkway, SuAe 301 Saint Paul, Minnesota 55116 651.690.5525 www.fin n-dan iels.com CONSULTANT: � DUNHAM �I DUNHAM m so�m s�.m s.��v s��n� noo M���o�pona,m����yoi�ssaoa-isao r..'.�61p,<65]550 nx61RA6'31561 ..�e tlunpamengr.om ecnamcai a eiecmcai consmnng eneineenng SEAL/SIGNATURE: W.NIOWOB �. ' STRTE Oi 12/ll/2019 PROJECT: � BIBIBOP asian grill THE BRIDGES 365 WEST 116TH STREET SUITE 140 CARMEL, INDIANA 46032 BIBIBOPSTORENO.: TBD BIBIBOP PO NO: THE BRIDGES PROIEQ NO.: 0 42 0 995-119 DRAWNBV: T%e CHECKE� eV' GMS ISSUES AND REVISIONS: LL/QIENTREVIEWSET 11262019 PERMITISSUE 12.112019 SHEET TITLE: PLUMBING SPECIFICATIONS P300