Loading...
HomeMy WebLinkAbout Energy Certificate6801 PULASKI CT CARM E L, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls. R-1.6_ ___ Foundation Walls R-13 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 2688 CFM50 (3.32 ACH50) Window U-Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-9.0, Return R-9.0 6 Duct Leakage to Outside 164 CFM @ 25Pa (3.01J100 s.f.) Total Duct Leakage 435 CFM @ 25Pa (Post -Construction) Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Natural Gas • 0.72 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Signature: Organization: TSI Energy Solutions Digitally signed: 1/29/20 at 12:04 PM Ekotrope RATER - Version 3.1.0.2345 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. RESNET HOME ENERGY RATI N G Standard Disclosure C"IEriergy Solutions For home(s) located at: 6801 PULASKI CT, CARMEL, IN Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page_ J011. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: E[A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself RID. Training for sales or construction personnel E. Other(specify) []3. The Rater or the Rater's employer is: E]A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home 4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products HVAC systems Installed in this home by []Rater Employer OR is in the business of Rater DEmployer Thermal insulation systems Rater Employer Rater Employer Air sealing of envelope or duct systems Rater Employer Rater WlEmployer Energy efficient appliances Rater Employer Rater Employer Construction (builder, developer, construction contractor, etc) Rater Employer Rater Employer Other (specify): Rater OEmployer Rater Employer []5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification #: 5935319 Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Digitally signed: 1129/20 at 12:04 PM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at http://resnet. us/standards/RESN ET_Mortgage_I nd ustry_National_H ERS_Standards. pdf The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Form 03001-2 - Amended April 24, 2007 Horne Energy Rating Certificate Rating Date: 2020-01-29 'f'S�Energysdutbns Final Report Registry ID:972686771 Ekotrope ID: M28wnV3v Your Home's Estimated Energy Use: Heating Cooling Hot Water Lights/Appliances Service Charges Generation (e.g. Solar) Total: Existing Homes Reference Home Zero Energy Home More Energy 150 140 130 L20 110 100 90 so 70 - — ft so This Home 40 30 20 10 0 Less Energy Use [MI3tu] Annual Cost 98.4 $ 628 3.9 $118 16.2 $99 35.5 $979 $273 0.0 $0 154.1 $2,097 Home Feature Summary: HomeType: Single family detached Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 Conditioned Floor Area: 5,446 ft2 Number of Bedrooms: 5 Primary Heating System: Furnace • Natural Gas • 95.5 AFUE Primary Cooling System: Air Conditioner • Electric • 13 SEER Primary Water Heating: Water Heater • Natural Gas • 0.72 Energy Factor House Tightness: 2688 CFM50 (3.32 ACH50) Ventilation: None ' Duct Leakage to Outside: 164 CFM @ 2513a (3.01 / 100 s.f.) Above Grade Walls: R-16 Ceiling: Attic, R-38 Window Type: U-Value: 0.33, SHGC: 0.28 Foundation Walls: R-13 This home meets or exceeds the criteria of the following: 2009 International Energy Conservation Code Rating Completed by: Energy Rater:MatthewTimmons RESNETID:5935319 Rating Company:TSI Energy Solutions 4650 Killarney Dr, Carmel IN 46082 317-846-4655 omw'a.. Rating Provider:TSI Energy Solutions 4650 Killarney Dr, Carmel IN 46082 -14a5' 317-846-4655 Matthew Timmons, Certified Energy Rater Digitally signed: 1/29/20 at 12.04 PM IECC 2009 Performance Compliance Property 6801 PULASKI CT CARMEL, IN 46033 Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 LRO94 (AS BUILT) LEGACY RIDGE 94_11009788 Organization Inspection Status TSI Energy Solutions 2020-01-29 Matthew Timmons Rater ID (RTIN): 5935319 RESNET Registered Builder (Confirmed) LENNAR HOMES C"UnergySoIL&ns Annual Energy Cost Design IECC 2009 Performance As Designed Heating $1,795 $1,501 Cooling $269 $212 Water Heating $206 $206 SubTotal Used to determine compliance _ $2,269 _ - $1,919 Lights & Appliances $963 $963 Onsite generation $0 $0 ;Total $2,882 Requirements 405.3 . Performance -based compliance passes by 15.4% " R402.4.1.2 Air Leakage Testing Air sealing is 3.32 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. 402.5 Area -weighted average fenestration SHGC J 402.5 Area -weighted average fenestration LI-Factor 403.2.2 Duct Testing Mandatory Checklist Mandatory code re quirements'that-are not checked by Ekotrope must be met - - - - - -- - R405 2 Duct Insulation °' Design exceeds requirements for IECC 2009 Performance compliance by 15.4%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedtlested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Signature: Organization: TSI Energy Solutions Digitally signed 1/29/20 at 12:04 PM Ekotrope RATER - Version 3.1.0.2345 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report