HomeMy WebLinkAbout Energy Certificate6801 PULASKI CT
CARM E L, IN 46033
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls. R-1.6_ ___
Foundation Walls R-13
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 2688 CFM50 (3.32 ACH50)
Window U-Value: 0.33, SHGC: 0.28
Building Features
Duct Supply R-9.0, Return R-9.0
6
Duct Leakage to Outside 164 CFM @ 25Pa (3.01J100 s.f.)
Total Duct Leakage 435 CFM @ 25Pa (Post -Construction)
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.72 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons Signature:
Organization: TSI Energy Solutions Digitally signed: 1/29/20 at 12:04 PM
Ekotrope RATER - Version 3.1.0.2345
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
RESNET HOME ENERGY
RATI N G Standard Disclosure C"IEriergy Solutions
For home(s) located at: 6801 PULASKI CT, CARMEL, IN
Check the applicable disclosure(s) in accordance with the
instructions on the reverse of this page_
J011. The Rater or the Rater's employer is receiving a fee for providing the rating on this home.
2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services
for this home:
E[A. Mechanical system design
B. Moisture control or indoor air quality consulting
C. Performance testing and/or commissioning other than required for the rating itself
RID. Training for sales or construction personnel
E. Other(specify)
[]3. The Rater or the Rater's employer is:
E]A. The seller of this home or their agent
B. The mortgagor for some portion of the financed payments on this home
C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home
4. The Rater or Rater's employer is a supplier or installer of products, which may include:
Products
HVAC systems
Installed in this home by
[]Rater Employer
OR is in the business of
Rater DEmployer
Thermal insulation systems
Rater
Employer
Rater
Employer
Air sealing of envelope or duct systems
Rater
Employer
Rater
WlEmployer
Energy efficient appliances
Rater
Employer
Rater
Employer
Construction (builder, developer, construction contractor, etc)
Rater
Employer
Rater
Employer
Other (specify):
Rater
OEmployer
Rater
Employer
[]5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification #: 5935319
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Digitally signed: 1129/20 at 12:04 PM
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
http://resnet. us/standards/RESN ET_Mortgage_I nd ustry_National_H ERS_Standards. pdf
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
RESNET Form 03001-2 - Amended April 24, 2007
Horne Energy Rating Certificate Rating Date: 2020-01-29 'f'S�Energysdutbns
Final Report Registry ID:972686771
Ekotrope ID: M28wnV3v
Your Home's Estimated Energy Use:
Heating
Cooling
Hot Water
Lights/Appliances
Service Charges
Generation (e.g. Solar)
Total:
Existing
Homes
Reference
Home
Zero Energy
Home
More Energy
150
140
130
L20
110
100
90
so
70
- —
ft
so This Home
40
30
20
10
0
Less Energy
Use [MI3tu]
Annual Cost
98.4
$ 628
3.9
$118
16.2
$99
35.5
$979
$273
0.0
$0
154.1
$2,097
Home Feature Summary:
HomeType:
Single family detached
Model:
3500 RIVIERA C
Community:
LEGACY RIDGE 94
Conditioned Floor Area:
5,446 ft2
Number of Bedrooms:
5
Primary Heating System:
Furnace • Natural Gas • 95.5 AFUE
Primary Cooling System:
Air Conditioner • Electric • 13 SEER
Primary Water Heating:
Water Heater • Natural Gas • 0.72 Energy Factor
House Tightness:
2688 CFM50 (3.32 ACH50)
Ventilation:
None '
Duct Leakage to Outside:
164 CFM @ 2513a (3.01 / 100 s.f.)
Above Grade Walls:
R-16
Ceiling:
Attic, R-38
Window Type:
U-Value: 0.33, SHGC: 0.28
Foundation Walls:
R-13
This home meets or exceeds the
criteria of the following:
2009 International Energy Conservation Code
Rating Completed by:
Energy Rater:MatthewTimmons
RESNETID:5935319
Rating Company:TSI Energy Solutions
4650 Killarney Dr, Carmel IN 46082
317-846-4655
omw'a..
Rating Provider:TSI Energy Solutions
4650 Killarney Dr, Carmel IN 46082
-14a5'
317-846-4655
Matthew Timmons, Certified Energy Rater
Digitally signed: 1/29/20 at 12.04 PM
IECC 2009 Performance Compliance
Property
6801 PULASKI CT
CARMEL, IN 46033
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94
LRO94 (AS BUILT)
LEGACY RIDGE 94_11009788
Organization Inspection Status
TSI Energy Solutions 2020-01-29
Matthew Timmons Rater ID (RTIN): 5935319
RESNET Registered
Builder (Confirmed)
LENNAR HOMES
C"UnergySoIL&ns
Annual Energy Cost
Design
IECC 2009 Performance
As Designed
Heating
$1,795
$1,501
Cooling
$269
$212
Water Heating
$206
$206
SubTotal Used to determine compliance
_ $2,269
_
- $1,919
Lights & Appliances
$963
$963
Onsite generation
$0
$0
;Total
$2,882
Requirements
405.3 . Performance -based compliance passes by 15.4% "
R402.4.1.2 Air Leakage Testing Air sealing is 3.32 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa.
402.5 Area -weighted average fenestration SHGC J
402.5 Area -weighted average fenestration LI-Factor
403.2.2 Duct Testing
Mandatory Checklist Mandatory code re quirements'that-are not
checked by Ekotrope must be met
- - - - - -- -
R405 2 Duct Insulation °'
Design exceeds requirements for IECC 2009 Performance compliance by 15.4%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspectedtlested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Signature:
Organization: TSI Energy Solutions Digitally signed
1/29/20 at 12:04 PM
Ekotrope RATER - Version 3.1.0.2345
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report