HomeMy WebLinkAbout Energy Certificate2614 LACEWOOD CT CARMEL, IN 46074 Builder: PULTE HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls N/A Framed Floor R-30 Slab R-10.0 Perimeter, R-10.0 Under Infiltration 1796 CFM50 (3.34 ACH50) Window U-Value: 0.31, SHGC: 0.3 Building Features Duct Supply R-25.0, Return R-25.0 Duct Leakage to Outside 174 CFM @ 25Pa (5.02 / 100 s.f.) Total Duct Leakage 503 CFM @ 25Pa (Post -Construction) Heating -Furnaee • Natural Gas • 95 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certif•; that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Michael Hill Signature: 40 Organization: TSI Energy Solutions Digitally signed: 2/14/20 at 9:44 AM Ekotrope RATER - Version 3.2.3.2360 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. IECC 2009 Performance Compliance Property 2614 LACEWOOD CT CARMEL, IN 46074 Model: BOURGES Community: SHADOW WOOD 19 SHWO19 (AS BUILT) SHADOW WOOD 19_11010755 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PULTE HOMES Design Heating Cooling Water Heating Su rota) - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status 2020-02-14 Rater ID (RTIN): 9479271 RESNET Registered (Confirmed) Annual Energy Cost IECC 2009 Performance $1,539 $233 $326 $2,099 $731 $0 $2,830 Requirements ® 405.3 Performance -based compliance passes by 15.9% ® R402.4.1.2 Air Leakage Testing ® 402.5 Area -weighted average fenestration SHGC ® 402.5 Area -weighted -average fenestration U-Factor!-- 4032.2 Duct Testing ® Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be ® R405.2 -met. Duct Insulation C"IEnergySclutions As Designed $1,272 $167 $326 $1,165 $734 $0 $2,499 Air sealing is 3.34 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 15.9%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Organization: Michael Hill TSI Energy Solutions Signature:�L� 40 Digitally signed: 2/14/20 at 9:44 AM Ekotrope RATER - Version 3.2.3.2360 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users Ekotrope disclaims all liabil ty for the information shown on this report