HomeMy WebLinkAbout Energy Certificate2614 LACEWOOD CT
CARMEL, IN 46074
Builder: PULTE HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls N/A
Framed Floor R-30
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 1796 CFM50 (3.34 ACH50)
Window U-Value: 0.31, SHGC: 0.3
Building Features
Duct Supply R-25.0, Return R-25.0
Duct Leakage to Outside 174 CFM @ 25Pa (5.02 / 100 s.f.)
Total Duct Leakage 503 CFM @ 25Pa (Post -Construction)
Heating -Furnaee • Natural Gas • 95 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certif•; that the address referenced above has been inspectedltested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Michael Hill Signature: 40
Organization: TSI Energy Solutions Digitally signed: 2/14/20 at 9:44 AM
Ekotrope RATER - Version 3.2.3.2360
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
IECC 2009 Performance Compliance
Property
2614 LACEWOOD CT
CARMEL, IN 46074
Model: BOURGES
Community: SHADOW WOOD 19
SHWO19 (AS BUILT)
SHADOW WOOD 19_11010755
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PULTE HOMES
Design
Heating
Cooling
Water Heating
Su rota) - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
2020-02-14
Rater ID (RTIN): 9479271
RESNET Registered
(Confirmed)
Annual Energy Cost
IECC 2009 Performance
$1,539
$233
$326
$2,099
$731
$0
$2,830
Requirements
®
405.3
Performance -based compliance passes by 15.9%
®
R402.4.1.2
Air Leakage Testing
®
402.5
Area -weighted average fenestration SHGC
®
402.5
Area -weighted -average fenestration U-Factor!--
4032.2
Duct Testing
®
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be
®
R405.2
-met.
Duct Insulation
C"IEnergySclutions
As Designed
$1,272
$167
$326
$1,165
$734
$0
$2,499
Air sealing is 3.34 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 15.9%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name:
Organization:
Michael Hill
TSI Energy Solutions
Signature:�L� 40
Digitally signed: 2/14/20 at 9:44 AM
Ekotrope RATER - Version 3.2.3.2360
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users
Ekotrope disclaims all liabil ty for the information shown on this report