Loading...
HomeMy WebLinkAbout Energy CertificateCARMEL, IN 46074 Builder: PULTE HOMES Building ;Features Ceiling Attic, R-38 Duct Supply R-22.0, Return R-22.0 Above Grade Walls R-15 Foundation Walls N/A Framed Floor R-30 Slab R-10.0 Perimeter, R-10.0 Under Infiltration 2133 CFM50 (3.97 ACH50) Window U-Value: 0.31, SHGC: 0.3 Duct Leakage -to Outside 131 CFM @ 25Pa (3.82 / 100 s.f.) Total Duct Leakage 400 CFM @ 25Pa (Post -Construction) Heating Furnace • Natural Gas • 95 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor i As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5_ If rating is Projected. I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been ins^pecc►tedtlested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. �L`J Name: Michael Hill Signature: Organization: TSI Energy Solutions Digitally signed: 2/14/20 at 9:23 AM Ekotrope RATER - Version 3.2.3.2360 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. IECC 2009 Performance Compliance Property 14482 CARLOW RUN CARMEL, IN 46074 Model: LYON Community: SHADOW WOOD 15 SHWO15 (AS BUILT) SHADOW WOOD 15_11010756 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PULTE HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status 2020-02-14 Rater ID (RTIN): 9479271 RESNET Registered (Confirmed) Annual Energy Cost IECC 2009 Performance $1,472 $245 $331 $2,048 $727 $0 $2,775 Requirements C"UnergySclutions As Designed $1,188 $167 $331 . $1,687 $729 $0 . $2,416 405.3 Performance based compliance passes by 17.6.% ® R402.4.12 Air Leakage Testing Air sealing is 3.97 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa 402.5 Area -weighted average fenestration SHGC ® 402.5 Area -weighted average fenestration U-Factor ® 403-2-2 Duct Testing- ®- —Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be m_et. ® R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 17.6%. As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Michael Hill Signature: 40 Organization: TSI Energy Solutions Digitally signed: 2/14/20 at 9:23 AM Ekotrope RATER - Jersion 3.2.3.2360 IECC 2004 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Too( All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report