HomeMy WebLinkAbout Energy CertificateCARMEL, IN 46074
Builder: PULTE HOMES
Building ;Features
Ceiling Attic, R-38 Duct Supply R-22.0, Return R-22.0
Above Grade Walls R-15
Foundation Walls N/A
Framed Floor R-30
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 2133 CFM50 (3.97 ACH50)
Window U-Value: 0.31, SHGC: 0.3
Duct Leakage -to Outside 131 CFM @ 25Pa (3.82 / 100 s.f.)
Total Duct Leakage 400 CFM @ 25Pa (Post -Construction)
Heating Furnace • Natural Gas • 95 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
i
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5_ If rating is Projected. I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been ins^pecc►tedtlested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. �L`J
Name: Michael Hill Signature:
Organization: TSI Energy Solutions Digitally signed: 2/14/20 at 9:23 AM
Ekotrope RATER - Version 3.2.3.2360
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
IECC 2009 Performance Compliance
Property
14482 CARLOW RUN
CARMEL, IN 46074
Model: LYON
Community: SHADOW WOOD 15
SHWO15 (AS BUILT)
SHADOW WOOD 15_11010756
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PULTE HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
2020-02-14
Rater ID (RTIN): 9479271
RESNET Registered
(Confirmed)
Annual Energy Cost
IECC 2009 Performance
$1,472
$245
$331
$2,048
$727
$0
$2,775
Requirements
C"UnergySclutions
As Designed
$1,188
$167
$331
. $1,687
$729
$0
. $2,416
405.3 Performance based compliance passes by 17.6.%
® R402.4.12 Air Leakage Testing Air sealing is 3.97 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa
402.5 Area -weighted average fenestration SHGC
® 402.5 Area -weighted average fenestration U-Factor
® 403-2-2 Duct Testing-
®- —Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be m_et.
® R405.2 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 17.6%.
As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Michael Hill Signature: 40
Organization: TSI Energy Solutions Digitally signed: 2/14/20 at 9:23 AM
Ekotrope RATER - Jersion 3.2.3.2360
IECC 2004 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Too( All results are based on data entered by Ekotrope users
Ekotrope disclaims all liability for the information shown on this report