Loading...
HomeMy WebLinkAbout Energy Certificate1g10vps tz 7275 ZANESVILLE RD CARM EL11 1 N 46033 Builder: LENNAR HOMES Building Features Ceiling Attic, R-38 Duct Supply R-6.0, Return R-6.0 ove-Grade-Walls- -R-16 Foundation Walls N/A Framed Floor R-38 Slab R-10.0 Perimeter, R-0.0 Under Infiltration 1828 CFM50 (6.84 ACH50) Window U-Value: 0.33, SHGC: 0.28 Duct Leakage to Outside 96 CFM-@-25Pa-(5.26-/-1-OO�f gp3 Total Duct Leakage 289 CFM @ 25Pa (Post -Construction) l Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted Intemational Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. - e Name: Matthew Timmons Signature: Organization: TSI Energy Solutions Digitally signed: 2/10/20 at 12:00 PM Ekotrope RATER - Version 3.1.0.2356 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. RESNET HOME ENERGY RATING Standard Disclosure C",Fnergy solutions For home(s) located at: 7275 ZANESVILLE RD, CARMEL, IN Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page. R11. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: E]A. Mechanical system design F] B. Moisture control or indoor air quality consulting 11C. Performance testing and/or commissioning other than required for the rating itself D. Training for sales or construction personnel E] E. Other(specify) [13. The Rater or the Rater's employer is: []A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home 4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products HVAC systems Installed in this home by Rater Employer OR is in the business of Rater Employer Thermal insulation systems Rater Employer Rater Employer Air sealing of envelope or duct systems Rater Employer Rater Employer Energy efficient appliances Rater Employer Rater Employer Construction (builder, developer, construction contractor, etc) Rater Employer Rater Employer Other (specify): I I Rater Employer Rater Employer 1]5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification #: 5935319 Name: Matthew Timmons Signature: Organization: TSI Energy Solutions Digitally signed: 2/10/20 at 12:00 PM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at http://resnet.us/standards/RESNET Mortgage_Industry_National_HERS _Standards.pdf The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Form 03001-2 -Amended April 24, 2007 IECC 2009 Performance Compliance - Property 7275 ZANESVILLE RD CARMEL, IN 46033 Model: LOCKERBIE (V) Community: LEGACY PRAIRIE 803 PRL803 (AS BUILT) LEGACY PRAIRIE 803_11004005 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating subTotal - Used to, determ_ ine compliance ... Lights & Appliances Onsite generation Inspection Status 2020-02-10 Rater ID (RTIN): 5935319 RESNET Registered (Confirmed) Annual Energy Cost IECC 2009 Performance $580 $88 $338 $1,006 $496 $0 Total - - $1,502 _ ..: .. - C"IErergySolutoris Requirements As Designed $576 $87 $338 -- 11,000 $496 405.3 Performance -based compliancepasses by 0.6% R402.4.1.2 Air Leakage Testing Air sealing is 6.84 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 403.2.2 Duct Testing ® t Mandatory code requirements that are not Mandatory Checklis checked by Ekotrope must be met. i R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 0.6%: As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that his energy code compliance document has been created in accordance with the requirements of Chapter of the adopted International Energy Conservation Code based on Climat Zone 5. If rating is Projected, I certify that the building design described herein Is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating Is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installedlto meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions i Signature: Digitally signed: 2/10/20 at 12:00 PM Ekotrope RAl ER - Version 3.1.0.2356 IECC 2009 Performance compliance results calculat ad using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liabiljty for the information shown on this report. Home Energy Rating Certificate Rating Date: 2020-02-10 TSiEmrgySolufws Final Report Registry ID: 247836347 p Ekotrope ID: KvpbbmKL Your Home's Estimated Energy Use: This home meets or exceeds the Use [MBtu] Annual Cost criteria of the following: Heating 44.3 $288 2009 International Energy Conservation Code Cooling 1.8 $54 Hot Water 9.9 $295 Lights/Appliances 19.0 $495 Service Charges $273 Generation (e.g. Solar) 0.0 $0 Total: 75.1 $1,405 HERS'Index Home Feature summary: Rating Completed by c>� More Energy Home Type: Townhouse, inside unit Energy Ra er•MatthewTimmons lso Model: LOCKERBIE (V) RESNET ID:5935319 Existing 140 Community: LEGACY PRAIRIE 803 Homes 130 RatingCom an TSI EnergySolutions 220 Conditioned Floor Area: 1,826 ftz 4650 Killarney Dr,Carmel IN 46082 w Number of Bedrooms: 3 Reference l317-846-4655 Home ioo Primary Heating System: Furnace • Natural Gas • 95.5 AFUE 90 Primary Cooling System: Air Conditioner • Electric • 13 SEER Rating Provider-.TSI Energy Solutions80 Primary Water Heating: Water Heater •Electric • 0.93 Energy Factor 4650 Killarney Dr, Carmel IN 46082 70_ 317-846-4655 House Tightness: 1828 CFM50 (6.84 ACH50) 60 This Home so Ventilation: None 40 Duct Leakage to Outside: 96 CFM @ 25Pa (5.26 / 100 s.f.) 30 Above Grade Walls: R-16 to to Ceiling: Attic, R-38 Zero Energy o Window Type: U-Value: 0.33, SHGC: 0.28 Home Loss Energy Foundation Walls: N/A Matthew Timmons, Certified Energy Rater 01017 REM � Digitally signed: 2/10/20 at 12:00 PM