HomeMy WebLinkAbout Energy Certificate1g10vps tz
7275 ZANESVILLE RD
CARM EL11 1 N 46033
Builder: LENNAR HOMES
Building Features
Ceiling Attic, R-38 Duct Supply R-6.0, Return R-6.0
ove-Grade-Walls- -R-16
Foundation Walls N/A
Framed Floor R-38
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 1828 CFM50 (6.84 ACH50)
Window U-Value: 0.33, SHGC: 0.28
Duct Leakage to Outside 96 CFM-@-25Pa-(5.26-/-1-OO�f
gp3
Total Duct Leakage 289 CFM @ 25Pa (Post -Construction)
l Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted Intemational Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. - e
Name: Matthew Timmons Signature:
Organization: TSI Energy Solutions Digitally signed: 2/10/20 at 12:00 PM
Ekotrope RATER - Version 3.1.0.2356
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
RESNET HOME ENERGY
RATING Standard Disclosure C",Fnergy solutions
For home(s) located at: 7275 ZANESVILLE RD, CARMEL, IN
Check the applicable disclosure(s) in accordance with the
instructions on the reverse of this page.
R11. The Rater or the Rater's employer is receiving a fee for providing the rating on this home.
2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services
for this home:
E]A. Mechanical system design
F] B. Moisture control or indoor air quality consulting
11C. Performance testing and/or commissioning other than required for the rating itself
D. Training for sales or construction personnel
E] E. Other(specify)
[13. The Rater or the Rater's employer is:
[]A. The seller of this home or their agent
B. The mortgagor for some portion of the financed payments on this home
C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home
4. The Rater or Rater's employer is a supplier or installer of products, which may include:
Products
HVAC systems
Installed in this home by
Rater Employer
OR is in the business of
Rater Employer
Thermal insulation systems
Rater
Employer
Rater
Employer
Air sealing of envelope or duct systems
Rater
Employer
Rater
Employer
Energy efficient appliances
Rater
Employer
Rater
Employer
Construction (builder, developer, construction contractor, etc)
Rater
Employer
Rater
Employer
Other (specify): I I
Rater
Employer
Rater
Employer
1]5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification #: 5935319
Name: Matthew Timmons Signature:
Organization: TSI Energy Solutions Digitally signed: 2/10/20 at 12:00 PM
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
http://resnet.us/standards/RESNET Mortgage_Industry_National_HERS _Standards.pdf
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
RESNET Form 03001-2 -Amended April 24, 2007
IECC 2009 Performance Compliance -
Property
7275 ZANESVILLE RD
CARMEL, IN 46033
Model: LOCKERBIE (V)
Community: LEGACY PRAIRIE 803
PRL803 (AS BUILT)
LEGACY PRAIRIE 803_11004005
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
subTotal - Used to, determ_ ine compliance ...
Lights & Appliances
Onsite generation
Inspection Status
2020-02-10
Rater ID (RTIN): 5935319
RESNET Registered
(Confirmed)
Annual Energy Cost
IECC 2009 Performance
$580
$88
$338
$1,006
$496
$0
Total - - $1,502 _ ..: .. -
C"IErergySolutoris
Requirements
As Designed
$576
$87
$338
-- 11,000
$496
405.3 Performance -based compliancepasses by 0.6%
R402.4.1.2 Air Leakage Testing Air sealing is 6.84 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa.
402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U-Factor
403.2.2 Duct Testing
® t Mandatory code requirements that are not
Mandatory Checklis
checked by Ekotrope must be met.
i R405.2 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 0.6%:
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that his energy code compliance document has been created in accordance with the requirements of
Chapter of the adopted International Energy Conservation Code based on Climat Zone 5. If rating is Projected, I certify that the building design described herein Is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating Is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installedlto meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
i
Signature:
Digitally signed: 2/10/20 at 12:00 PM
Ekotrope RAl ER - Version 3.1.0.2356
IECC 2009 Performance compliance results calculat ad using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liabiljty for the information shown on this report.
Home Energy Rating Certificate Rating Date: 2020-02-10 TSiEmrgySolufws
Final Report Registry ID: 247836347
p Ekotrope ID: KvpbbmKL
Your Home's Estimated Energy Use: This home meets or exceeds the
Use [MBtu] Annual Cost criteria of the following:
Heating 44.3 $288 2009 International Energy Conservation Code
Cooling 1.8 $54
Hot Water 9.9 $295
Lights/Appliances 19.0 $495
Service Charges $273
Generation (e.g. Solar) 0.0 $0
Total: 75.1 $1,405
HERS'Index Home Feature summary: Rating Completed by
c>� More Energy Home Type: Townhouse, inside unit Energy Ra er•MatthewTimmons
lso Model: LOCKERBIE (V) RESNET ID:5935319
Existing 140 Community: LEGACY PRAIRIE 803
Homes 130 RatingCom an TSI EnergySolutions
220 Conditioned Floor Area: 1,826 ftz 4650 Killarney Dr,Carmel IN 46082
w Number of Bedrooms: 3
Reference l317-846-4655
Home ioo Primary Heating System: Furnace • Natural Gas • 95.5 AFUE
90 Primary Cooling System: Air Conditioner • Electric • 13 SEER Rating Provider-.TSI Energy Solutions80
Primary Water Heating: Water Heater •Electric • 0.93 Energy Factor 4650 Killarney Dr, Carmel IN 46082
70_ 317-846-4655
House Tightness: 1828 CFM50 (6.84 ACH50)
60 This Home
so Ventilation: None
40 Duct Leakage to Outside: 96 CFM @ 25Pa (5.26 / 100 s.f.)
30 Above Grade Walls: R-16
to
to Ceiling: Attic, R-38
Zero Energy o Window Type: U-Value: 0.33, SHGC: 0.28
Home Loss Energy Foundation Walls: N/A Matthew Timmons, Certified Energy Rater
01017 REM � Digitally signed: 2/10/20 at 12:00 PM