HomeMy WebLinkAbout Energy Certificate7277 ZAN.P,,SVILLE RD CARMEL,,, IN 46033 Builder: LENNAR HOMES Model: MERIDIAN_111 Community: LEGACY PRAIRIE 804 Ceiling Attic, R-38 Above -Grade -Walls- R-1-6 Foundation Walls N/A Framed Floor R-30 Slab R-10.0 Perimeter, R-0.0 Under Infiltration 1586 CFM50 (4.87 ACH50) Window U-Value: 0.33, SHGC: 0.28 Building' Features Duct Supply R-8.0, Return R-8.0 Duct Leakage -to -Outside 1-28-CFM @ 25Pa-(5:49-/ 1-00-s.f )---- -- Total Duct Leakage 299 CFM @ 25Pa (Post -Construction) Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5- If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of I the IECC or will be verified as such by another party. Name: Michael Hill 'i Signature: Organization: TSI Energy Solutions Digitally signed: 2/6/20 at 3:13 PM Ekotrope RATER - Version 3.2.3.2351 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. RESNET HOME ENERGY RATING Standard Disclosure C",EneWSo`utions For home(s) located at: 7277 ZANESVILLE RD, CARMEL, IN Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page: M1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: E]A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself RID. Training for sales or construction personnel 0 E. Other(specify) []3. The Rater or the Rater's employer is: []A. The seller of this home or their agent E] B. The mortgagor for some portion of the financed payments on this home LIC. An employee, contractor, or consultant ofthe electric and/or natural gas utility serving this home R14. The Rater or Rater's employer is a supplier or installer of products, which may include: Products HVAC systems Installed in this home by Rater Employer OR is in the business of Rater Employer Thermal insulation systems Rater Employer DRater Employer Air sealing of envelope or duct systems Rater VEmployer Rater Employer Energy efficient appliances Rater Employer Rater Employer Construction (builder, developer, construction contractor, etc) Rater Employer Rater Employer Other (specify): Rater Employer Rater Employer []5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification #: 9479271 Name: Michael Hill Organization: TSI Energy Solutions Signature: Digitally signed: 2/6/20 at 3:13 PM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at http://resnet.us/standards/RESNET Mortgage_Industry_National_HERS_Standards.pdf The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Form 03001-2 -Amended April 24, 2007 l Home Energy Rating Certificate Final Report Your Home's Estimated Energy Use: Heating Cooling Hot Water Lights/Appliances Service Charges Generation (e.g. Solar) Total: Existing Homes Reference Home Zero Energy Home More Energy 150 140 230 120 un 100 90 o 70 '0 so This Home 40 30 10 20 0 Lev Energy Rating Date: 2020-02-06 Registry ID: 463975967 Ekotrope ID: Od4aaDYv Use [MBtu] Annual Cost 51.9 $338 2.4 $73 9.5 $285 21.2 $562 — - $273 0.0 $0 85.1 $1,533 Home Feature Summary: Home Type: Townhouse, inside unit Model: MERIDIAN III Community: LEGACY PRAIRIE 804 Conditioned Floor Area: 2,330 ft2 Number of Bedrooms: 3 Primary Heating System: Furnace • Natural Gas • 95.5 AFUE Primary Cooling System: Air Conditioner • Electric • 13 SEER Primary Water Heating: Water Heater • Electric • 0.93 Energy Factor House Tightness: 1586 CFM50 (4.87 ACH50) Ventilation: None Duct Leakage to Outside: 128 CFM @ 25Pa (5.49 / 100 s.f.) Above Grade Walls: R-16 Ceiling: Attic, R-38 Window Type: U-Value: 0.33, SHGC: 0.28 Foundation Walls: N/A C",Erergy Soluflons This home meets or exceeds the criteria of the following: 2009 International Energy Conservation Code Rating Completed by: Energy Rater:Michael Hill RESNETID:9479271 Rating Company:TSI Energy Solutions 4650 Killarney Dr, Carmel IN 46082 317-846-4655 Rating Provider:TSI Energy Solutions 4650 Killarney Dr, Carmel IN 46082r 1� 317-846-4655 Michael Hill, Certified Energy Rater Digitally signed: 2/6/20 at 3:13 PM IECC 2009 Performance Compliance Property Organization 7277 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: MERIDIAN III Michael Hill Community: LEGACY PRAIRIE 804 Builder PRL804 (AS BUILT) LENNAR HOMES LEGACY PRAIRIE 804_11004008 Design Heating Cooling Water Heating SubTofa_I - Used to determine- compliance Lights & Appliances Onsite generation Inspection Status 2020-02-06 Rater ID (RTIN): 9479271 RESNET Registered (Confirmed) Annual Energy Cost IECC 2009 Performance $843 $122 $332 _ - $1,296,_ $559 - $0 Total. _.... $1856 Requirements C",EnergySolufions As Designed $667 $117 $332 $559 $0 405.3 Performance -based compliance passes by 13.9% " R402.4.1.2 Air Leakage Testing Air sealing is 4.87 ACH at 50 Pa. It must not exceed 7-00 ACH at 50 Pa. 402.5 Area-wei hted average fenestration SHGC 9 9 ® _ 402.5 Area -weighted average fenestration Ll-Factor 403.2.2 - ' Duct Testing_','. ® Mandatory Checklist Mandatory code requirements that are not checked_by Ekotrope must be met k405 2, Duct InsLilationi. Design exceeds requirements for IECC 2009 Performance compliance by 13.9%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Organization: Michael Hill TSI Energy Solutions Signature: 40 Digitally signed: 2/6/20 at 3:13 PM Ekotrope RATER - Version 3.2.3.2351 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report