Loading...
HomeMy WebLinkAboutALT_MAYFLOWERparkDR-C2-SITE260.00'30.0' 10.9'60.0' 80.0'20.0' 19.9' 31.3' 20.0' 25.0' 20.0' 10.0'5.0'(11) - 9' x 20' PARKING SPACES(11) - 9'x20' SPACES(7) - 9'x20' SPACESPRE CAST OFFICE / WAREHOUSE 81,120 sq.ft. N 89°23'52" E 551.27' S 89°23'52" W 551.10'N 00°24'08" W 458.37'S 00°22'52" E 458.37'12' x 14' O.H. DOOR(11) - 9' x 20' PARKING SPACES(8) - 9' x 20' SPACES(10) - 9' x 20' PARKING SPACES(6) - 10' x 20' SPACES(11) - 9' x 20' PARKING SPACES (11) - 9' x 20' PARKING SPACES 14 TRUCK DOCKS MAN DOOR MAN DOOR MAN DOOR MAN DOOR 44.5'101.9'MAYFLOWER PARK DRIVEHEAVY-DUTY ASPHALT DRIVELIGHT-DUTY ASPHALTDRIVE/PAVEMENT MAYFLOWER PARK LOT 5 BLOCK 6 INSTR. NO. 2016005226 MAYFLOWER PARK LOT 1 BLOCK 7 INSTR. NO. 2000045587 BURLEN REALITY, INC.INSTR. NO. 20010610164.400 Ac.+/-MAYFLOWER PARK LOT 1 BLOCK 6 INSTR. NO. 2000045587 MECH. ROOM PROVIDE SHUT OFF FOR 28' - 1" DOMESTIC WATER TO 1" INTERIOR METER WITH RPZ BACKFLOW PREVENTER PER CARMEL DETAILS & STANDARDS INSTALL 26' - 6" D.I. (MATCH EXISTING SIZE), INSTALL NEW FIRE HYDRANT & VALVE PER CARMEL UTILITIES STANDARDS 108' - 6" D.I. TO FIRE DEPARTMENT CONNECTION W/ 5" "STORZ", VERIFY TYPE SIZE AND LOCATION WITH SPRINKLER CONTRACTOR & FIRE DEPARTMENT 150' - 8" D.I. AWWA WATER FIRE LINE PER CARMEL DETAILS 5' x 70' CONCRETE APRON MAN DOOR 9' x 10' DOCK 9' x 10' DOCK 9' x 10' DOCK 9' x 10' DOCK 12' x 14' O.H. DOOR 9' x 10' DOCK 9' x 10' DOCK 9' x 10' DOCK 9' x 10' DOCK 9' x 10' DOCK 9' x 10' DOCK 9' x 10' DOCK 9' x 10' DOCK R 1 5 .0' R10 .0' R 2 0 . 0 '14.0'19.9'10.5'169.0'22.5' LANDSCAPING STRIPING OVER CONC. LANDSCAPING 5' x 20' CONCRETE APRON R10.0'TAP WATER LINE & PROVIDE VALVE PER CARMEL UTILITY STANDARDS 25.0'R2 0.0' R20.0' MAINTAIN MINIMUM 18" VERTICAL SEPERATION FROM ALL NEW & EXISTING WATER LINES PER CARMEL UTILITIES STANDARDS PROVIDE (4) 4" - 146' PVC CONDUITS TO CT CABINET VERIFY TYPE SIZE AND LOCATION W/ I.P.L.LIGHT-DUTY ASPHALTDRIVE/PAVEMENT PROVIDE 10' - 6" PVC @ 16% & CLEAN OUT PER TRICO STANDARDS & DETAILS (INV. -6.5' B.F.F.E. = 886.36' ) c.o. GAS METER, VERIFY TYPE SIZE AND LOCATION W/ VECTREN, PROVIDE 6" CONC/STEEL PIPE BOLLARDS TAP GAS LINE, VERIFY TYPE, SIZE, AND LOCATION W/ VECTREN PROVIDE NEW PRIVATE FIRE HYDRANT (PAINTED RED) & VALVE PER CARMEL UTILITIES STANDARDS 483' - 6" AWWA D.I. WATER FIRE LINE PER CARMEL DETAILS HEAVY-DUTY ASPHALT DRIVE HEAVY-DUTY ASPHALT DRIVE 6" CONC. BARRIER CURB (TYP) SEE DETAILS & CARMEL NOTES312.0'14.0' PROVIDE MINIMUM OF 18" VERTICAL SEPERATION FROM WATER LINE TO SANITARY MAIN PER CARMEL UTILITY & TRICO STANDARD DETAILS PROVIDE E604-SWCR-07 ADA RAMP FOR SIDEWALK SEE DETAIL ON SHEET C5.2 PROVIDE E604-SWCR-07 ADA RAMP FOR SIDEWALK SEE DETAIL ON SHEET C5.2 PROVIDE ADA PARKING SIGN SEE DETAIL 6/C5.1 PROVIDE ADA PARKING SIGN SEE DETAIL 6/C5.1 43.6'PROVIDE (4) - BICYCLE PARKING SPACES IN FRONT (5) - BICYCLE PARKING SPACES TO BE PROVIDED INSIDE WAREHOUSE MAN DOOR 9' x 10' DOCK 9' x 10' DOCK 20'RNEW RAMP SEE DETAIL ON SHEET C5.2 NEW RAMP SEE DETAIL ON SHEET C5.2 NEW 125'-5' SIDEWALK NEW 17'-5' SIDEWALK MAYFLOWER PARK LOT 2 BLOCK 7 PERFORMANCE SERVICES REAL ESTATE, LLC INSTR. NO. 2015025148 5.800 Ac. +/- POND AERATOR SEE NOTES ON C5.3 and SPECS ON C5.4 WARNING SIGN & RESQUE EQUIPMENT @ 400' o.c., SEE NOTES ON C5.3 (typ) 45° BENDS PER CARMEL UTILITY REQUIREMENTS 2-45° BENDS PER CARMEL UTILITY REQUIREMENTS (TYP) 60'' CONCRETE TRUCK DOCK APRON (2)-45°BENDSPERCARMEL UTILITYREQUIREMENTS (TYP) TAP FOR FIRE HYDRANT LINE PER CARMEL UTILITY REQUIREMENTS (TYP), REPAIR APPROACH, CURB & PAVEMENT PER DETAILS ON C5.1 PROVIDE MINIMUM OF 18" VERT. or 10' HOR. SEPERATION FROM WATER LINE TO SANITARY MAIN PER CARMEL UTILITY & TRICO STANDARD DETAILS 0.7' WARNING SIGN RAIN GARDEN RAIN GARDEN PLANTINGS SEE DETAIL ON SHEET L2 ASPHALT & CURB REPAIR FOR WATER LINE PER DETAILS ON C5.1 316' - 2' WIDE RECON- BLOCK RETAINING WALL SEE DETAILS ON C 5.4 WARNING SIGN RAIN GARDEN POND AERATOR SEE NOTES ON C5.3 and SPECS ON C5.4 POST MOUNTED AIR COMPRESSOR FOR AERATOR, SEE NOTES ON C5.3 and SPECS ON C5.4 CLIENT REVIEW4-23-2019C2 1903-016KEELER-WEBB ASSOCIATESPROPOSED SITE PLAN PROPOSED OFFICE / WAREHOUSE10650 N. BENNETT PARKWAY, SUITE 200ZIONSVILLE, IN 46077 (317) 253-1251LEGEND SEE ARCH PLANS FOR INTERIOR LAYOUT, AND BUILDING DIMENSIONS 9801 Mayflower Park DriveCarmel, Indiana 460321 TAC REVIEW COMMENTS7-12-20191 1 1 CONTRACTOR TO POT HOLE TO FIND AND PROTECT THE EXISTING 4" GAS LINE PRIOR TO CONSTRUCTION OF NORTH ENTRY DRIVE APPROACH.ENGINEERING REVISIONS9-02-2019PLEASE MAKE APPLICATION FOR RELOCATION OF GAS SERVICE LINE BY CALLING OUR NEW SERVICE CENTER AT 1-800-990-1930. IF ADDING ADDITIONAL LOAD PLEASE GIVE THAT INFORMATION TO THEM AS WELL.SOUTH FH & DOMESTIC REV.9-11-20192 2 BUILD. SOUTH/POND ENLARGED9-23-20193 3 3 3 3 3 3 3 3 3 3 3 3 3 3 ENGINEERING & UTILITY REVISIONS10-22-20194 4 4 4 4 02/18/20