HomeMy WebLinkAboutALT_MAYFLOWERparkDR-C2-SITE260.00'30.0' 10.9'60.0' 80.0'20.0' 19.9'
31.3' 20.0' 25.0' 20.0' 10.0'5.0'(11) - 9' x 20' PARKING SPACES(11) - 9'x20' SPACES(7) - 9'x20' SPACESPRE CAST OFFICE / WAREHOUSE
81,120 sq.ft.
N 89°23'52" E 551.27'
S 89°23'52" W 551.10'N 00°24'08" W 458.37'S 00°22'52" E 458.37'12' x 14'
O.H. DOOR(11) - 9' x 20' PARKING SPACES(8) - 9' x 20' SPACES(10) - 9' x 20' PARKING SPACES(6) - 10' x 20' SPACES(11) - 9' x 20' PARKING SPACES (11) - 9' x 20' PARKING SPACES 14 TRUCK DOCKS
MAN DOOR
MAN DOOR
MAN DOOR
MAN DOOR
44.5'101.9'MAYFLOWER PARK DRIVEHEAVY-DUTY ASPHALT
DRIVELIGHT-DUTY ASPHALTDRIVE/PAVEMENT
MAYFLOWER PARK
LOT 5 BLOCK 6
INSTR. NO. 2016005226
MAYFLOWER PARK
LOT 1 BLOCK 7
INSTR. NO. 2000045587 BURLEN REALITY, INC.INSTR. NO. 20010610164.400 Ac.+/-MAYFLOWER PARK
LOT 1 BLOCK 6
INSTR. NO. 2000045587
MECH.
ROOM
PROVIDE SHUT OFF FOR
28' - 1" DOMESTIC WATER
TO 1" INTERIOR METER
WITH RPZ BACKFLOW
PREVENTER PER CARMEL
DETAILS & STANDARDS
INSTALL 26' - 6" D.I. (MATCH EXISTING
SIZE), INSTALL NEW FIRE HYDRANT &
VALVE PER CARMEL UTILITIES
STANDARDS
108' - 6" D.I. TO FIRE DEPARTMENT
CONNECTION W/ 5" "STORZ",
VERIFY TYPE SIZE AND LOCATION
WITH SPRINKLER CONTRACTOR & FIRE
DEPARTMENT
150' - 8" D.I. AWWA WATER FIRE
LINE PER CARMEL DETAILS
5' x 70' CONCRETE
APRON
MAN DOOR
9' x 10'
DOCK
9' x 10'
DOCK
9' x 10'
DOCK
9' x 10'
DOCK
12' x 14'
O.H. DOOR
9' x 10'
DOCK
9' x 10'
DOCK
9' x 10'
DOCK
9' x 10'
DOCK
9' x 10'
DOCK
9' x 10'
DOCK
9' x 10'
DOCK
9' x 10'
DOCK
R
1
5
.0'
R10 .0'
R
2
0
.
0
'14.0'19.9'10.5'169.0'22.5' LANDSCAPING
STRIPING OVER CONC.
LANDSCAPING
5' x 20' CONCRETE
APRON R10.0'TAP WATER LINE & PROVIDE VALVE
PER CARMEL UTILITY STANDARDS
25.0'R2 0.0'
R20.0'
MAINTAIN MINIMUM 18" VERTICAL
SEPERATION FROM ALL NEW &
EXISTING WATER LINES PER
CARMEL UTILITIES STANDARDS
PROVIDE (4) 4" - 146' PVC
CONDUITS TO CT CABINET VERIFY
TYPE SIZE AND LOCATION W/ I.P.L.LIGHT-DUTY ASPHALTDRIVE/PAVEMENT
PROVIDE 10' - 6" PVC @ 16% &
CLEAN OUT PER TRICO
STANDARDS & DETAILS (INV. -6.5'
B.F.F.E. = 886.36' )
c.o.
GAS METER, VERIFY TYPE SIZE AND
LOCATION W/ VECTREN, PROVIDE
6" CONC/STEEL PIPE BOLLARDS
TAP GAS LINE, VERIFY TYPE,
SIZE, AND LOCATION W/
VECTREN
PROVIDE NEW PRIVATE FIRE
HYDRANT (PAINTED RED) & VALVE
PER CARMEL UTILITIES STANDARDS
483' - 6" AWWA D.I. WATER FIRE LINE PER CARMEL DETAILS
HEAVY-DUTY ASPHALT
DRIVE
HEAVY-DUTY ASPHALT
DRIVE
6" CONC. BARRIER CURB (TYP)
SEE DETAILS & CARMEL NOTES312.0'14.0' PROVIDE MINIMUM OF 18" VERTICAL
SEPERATION FROM WATER LINE TO
SANITARY MAIN PER CARMEL UTILITY &
TRICO STANDARD DETAILS
PROVIDE E604-SWCR-07
ADA RAMP FOR SIDEWALK
SEE DETAIL ON SHEET C5.2
PROVIDE E604-SWCR-07
ADA RAMP FOR SIDEWALK
SEE DETAIL ON SHEET C5.2
PROVIDE ADA PARKING SIGN
SEE DETAIL 6/C5.1
PROVIDE ADA PARKING SIGN
SEE DETAIL 6/C5.1
43.6'PROVIDE (4) - BICYCLE PARKING
SPACES IN FRONT (5) - BICYCLE
PARKING SPACES TO BE PROVIDED
INSIDE WAREHOUSE
MAN DOOR
9' x 10'
DOCK
9' x 10'
DOCK
20'RNEW RAMP SEE DETAIL
ON SHEET C5.2
NEW RAMP SEE DETAIL
ON SHEET C5.2
NEW 125'-5' SIDEWALK NEW 17'-5' SIDEWALK
MAYFLOWER PARK
LOT 2 BLOCK 7
PERFORMANCE SERVICES REAL ESTATE, LLC
INSTR. NO. 2015025148
5.800 Ac. +/-
POND AERATOR
SEE NOTES ON C5.3
and SPECS ON C5.4
WARNING SIGN & RESQUE
EQUIPMENT @ 400' o.c.,
SEE NOTES ON C5.3 (typ)
45° BENDS PER CARMEL UTILITY
REQUIREMENTS
2-45° BENDS PER CARMEL
UTILITY REQUIREMENTS (TYP)
60'' CONCRETE
TRUCK DOCK APRON
(2)-45°BENDSPERCARMEL
UTILITYREQUIREMENTS (TYP)
TAP FOR FIRE HYDRANT
LINE PER CARMEL UTILITY
REQUIREMENTS (TYP),
REPAIR APPROACH,
CURB & PAVEMENT PER
DETAILS ON C5.1
PROVIDE MINIMUM OF 18" VERT. or 10'
HOR. SEPERATION FROM WATER LINE
TO SANITARY MAIN PER CARMEL UTILITY
& TRICO STANDARD DETAILS
0.7'
WARNING SIGN
RAIN GARDEN
RAIN GARDEN PLANTINGS
SEE DETAIL ON SHEET L2
ASPHALT & CURB REPAIR FOR WATER
LINE PER DETAILS ON C5.1
316' - 2' WIDE RECON- BLOCK
RETAINING WALL SEE DETAILS ON C 5.4
WARNING SIGN
RAIN GARDEN
POND AERATOR
SEE NOTES ON C5.3
and SPECS ON C5.4
POST MOUNTED AIR
COMPRESSOR FOR
AERATOR, SEE NOTES ON
C5.3 and SPECS ON C5.4 CLIENT REVIEW4-23-2019C2
1903-016KEELER-WEBB ASSOCIATESPROPOSED SITE PLAN PROPOSED OFFICE / WAREHOUSE10650 N. BENNETT PARKWAY, SUITE 200ZIONSVILLE, IN 46077 (317) 253-1251LEGEND
SEE ARCH PLANS FOR INTERIOR LAYOUT, AND
BUILDING DIMENSIONS 9801 Mayflower Park DriveCarmel, Indiana 460321 TAC REVIEW COMMENTS7-12-20191
1
1
CONTRACTOR TO POT HOLE TO FIND AND
PROTECT THE EXISTING 4" GAS LINE PRIOR
TO CONSTRUCTION OF NORTH ENTRY
DRIVE APPROACH.ENGINEERING REVISIONS9-02-2019PLEASE MAKE APPLICATION FOR RELOCATION
OF GAS SERVICE LINE BY CALLING OUR NEW
SERVICE CENTER AT 1-800-990-1930. IF ADDING
ADDITIONAL LOAD PLEASE GIVE THAT
INFORMATION TO THEM AS WELL.SOUTH FH & DOMESTIC REV.9-11-20192
2 BUILD. SOUTH/POND ENLARGED9-23-20193
3
3
3
3
3
3
3
3 3
3
3
3
3
3
ENGINEERING & UTILITY REVISIONS10-22-20194
4
4
4
4
02/18/20