From:Plan Review <planreview@dhs.in.gov>
Sent:Tuesday, January 21, 2020 4:09 PM
To:Jeremy Siegel
Subject:RE: Request for Construction Design Release (CDR)
Hello Mr. Siegel,
Based on the information and attachment provided, the project is EXEMPT from filing with the State of Indiana DHS Plan
Review section in accordance with 675 IAC 12‐6‐4
675 IAC 12-6-4 Exemptions from design release requirement
Authority: IC 22-13-2-13
Affected: IC 4-21.5; IC 12-13-4-3; IC 22-15-3
Sec. 4.
(b) Design releases are necessary for the remodeling or altering of all Class 1 structures, except work limited to one (1) or more of the
following:
(2) Plumbing work as follows:
(A) Replacement of piping, valves, or fixtures, provided that the replacement does not involve relocation of fixtures.
(B) Installation of plumbing fixtures, provided that the drainage fixture unit count does not exceed five (5).
(C) Replacement of water heaters with a similar type and capacity in the same location.
(D) Installation of water heaters with a capacity of one hundred (100) gallons or less.
(3) Electrical work as follows:
(A) Replacement in the same location of electrical equipment or devices of a similar type and rating, including an increase in current
capacity in nonhazardous areas where there is no change in voltage or phases.
(D) Installation of branch circuits not exceeding the capacity of the electrical distribution system within the existing building.
(E) Low-energy power, control, and signal circuits of Classes II and III as defined in the Indiana Electrical Code except circuits for
fire detection or fire alarm systems.
(G) Except for fire detection or fire alarm systems, electrical wiring, devices, appliances, apparatus, or equipment:
(i) operating at less than twenty-five (25) volts; and
(ii) not capable of supplying more than fifty (50) watts of energy.
(4) Mechanical work as follows:
(B) Replacement of mechanical appliances and equipment with a similar type and rating in the same location.
(5) Miscellaneous work as follows: (A) Painting, papering, and replacement of coverings on:
(i) walls;
(ii) ceilings;
(iii) roofs; or
(iv) floors;
and similar finish work, including replacement or reglazing of glass.
(B) Cases, counters, and partitions not over six (6) feet in height.
(C) Penetrations of nonfire‐rated exterior walls where the width of the opening: (i) does not exceed six (6) feet; and
(ii) is not for a required exit.
(D) Installation of one (1) or more nonload‐bearing partitions not to exceed a total of one hundred (100) lineal feet in length
provided it is not part of a corridor or a partition that is required to be of fire‐resistive construction.
(c) All additions or alterations permitted by this subdivision [sic.] shall be documented by the installer and kept on file with the
maintenance and testing records required by 675 IAC 22 and 675 IAC 28, specifically the applicable editions of NFPA 13 and NFPA
25.
(d) The design release requirements including filing of plans and specifications shall apply for any work otherwise exempted by
subsection (b) when a part of, supplemental to, or an accessory of a construction project that otherwise requires a design release.
(e) Construction work on a Class 1 structure exempted from the design release requirements under this section is not exempt from
compliance with other rules of the commission.
You may be required to submit to local jurisdiction.
2
Thank you,
From: Jeremy Siegel <jeremy@cshomes.com>
Sent: Tuesday, January 21, 2020 4:02 PM
To: Plan Review <planreview@dhs.in.gov>
Subject: RE: Request for Construction Design Release (CDR)
**** This is an EXTERNAL email. Exercise caution. DO NOT open attachments or click links from
unknown senders or unexpected email. ****
Hello,
1. Total linear feet is less than 100’
2. We will not be needing to add any additional panel or upgrade the service.
Jeremy Siegel | Project Manager | Christopher Scott Homes
__________________________________________________________________________________________
736 Hanover Place – Suite 100F | Carmel, IN 46032
Tel: 317.565.9441 | Fax: 317.257.7855
Jeremy@cshomes.com | www.cshomes.com
From: Plan Review <planreview@dhs.in.gov>
Sent: Tuesday, January 21, 2020 3:35 PM
To: Jeremy Siegel <jeremy@cshomes.com>
Subject: RE: Request for Construction Design Release (CDR)
Good Afternoon Jeremy,
Just a few questions if I may:
1. Is the total wall area more 100 liner feet?
2. Will you need to install new panel (s) to carry the new load? Or upgrade the service?
Thank You,
From: Jeremy Siegel <jeremy@cshomes.com>
Sent: Monday, January 20, 2020 1:56 PM
To: Plan Review <planreview@dhs.in.gov>
Cc: Scott Bates <scott@cshomes.com>; Chris Carnell <chris@cshomes.com>
Subject: Request for Construction Design Release (CDR)
**** This is an EXTERNAL email. Exercise caution. DO NOT open attachments or click links from
unknown senders or unexpected email. ****
Hello,
3
This is Jeremy with Christopher Scott Homes here in Carmel, IN. We’re planning on adding a few demising walls as part
of our small office renovation. These walls are NOT going to the roof deck and they will contain some electrical.
I’ve attached the proposed plan to this email. Please note that the walls highlighted in blue are the new walls we plan on
building, gray is existing.
Let me know if there’s anything you need!
Thanks,
Jeremy Siegel | Project Manager | Christopher Scott Homes