HomeMy WebLinkAboutA000.31900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2020
Zach Bittner08/04/2014
Right
Skyview
2056.300.00.CPM
LOT 01
01/08/2020
PLOTTED: January 24, 2020 / Kamlesh Bisht / 2056-SKYVIEW-CZ-BASE-EL-EC2M.DWG
A3-EC2M
3SB.1Euro Country 2M3 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleSCALE:FRONT ELEVATION1/4" = 1'-0"-
1212
1212
1212
1212
12121212
STONE SILL, PER SPEC.
ROOF SHINGLES, PER SPEC
6" RAKE BOARD, PER SPEC
STONE VENEER, PER SPEC
(2) FYPON # LV18X30\POR APPROVED EQUAL
FRIEZE, PER SPEC
TOP OF FOUNDATION
TOP OF FLOOR
TOP OF PLATE
WINDOW HEAD HGT.
WINDOW HEAD HGT.
TOP OF PLATE
TOP OF FLOOR
8" TRIM, PER SPEC
6" FASCIA BOARD, PER SPEC
ROOF SHINGLES, PER SPEC
6" CORNER BOARD, PER SPEC
10" FRIEZE, PER SPEC
1212
1212 12 5
2040 FX BLACKED OUT WINDOWS
CL-02AD 2.1SIMILAR
STONE SILL, PER SPEC
HORIZONTAL SIDING, PER SPEC
FYPON #BKT30X30X8, OR APPROVED EQUAL
FYPON #LV8X24, OR APPROVED EQUAL
\A1;4'-6"
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;
\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;
\A1;8'-1{\H0.750000x;\S1#8;}"
\A1;
\A1;7'-2{\H0.750000x;\S7#8;}"
\A1;
\A1;7'-2{\H0.750000x;\S7#8;}"
\A1;\A1;4'-2{\H0.750000x;\S7#8;}"
SMOOTH PANNEL, PER SPEC
MIN. 6" CLEARANCE BELOW SILL FOR FLASHING, PER DETAIL
SCALE:REAR ELEVATION1/8" = 1'-0"-
\A1;7'-8"\PHDR. HGT.\A1;7'-8"\PHDR. HGT.
1212 1212 12121212
MASONRY WAINSCOT
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;8'-1{\H0.750000x;\S1#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
TOP OF FOUNDATIONTOP OF FLOOR
TOP OF PLATETOP OF FLOOR
TOP OF PLATE
ROOF SHINGLES, PER SPEC
HORIZONTAL SIDING, \PPER SPEC
SCALE:LEFT ELEVATION1/8" = 1'-0"-
128128
128
124
MASONRY WAINSCOT
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
128128 128
\pxql;8" TRIM, PER SPEC.\pxql;6" TRIM, PER SPEC.
12:12
12:12
12:12
4:12
8:12
8:12
4:12
\A1;1'-0"\PTYP.
12:1212:12
12:12
8:12
8:12
12:12
8:12
12:1212:12 12:1212:1212:1212:12 8:128:12
\A1;7'-0"\A1;11'-0"\A1;10'-8{\H0.750000x;\S1#8;}"
MIN. 303 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"4:12
SCALE:ROOF PLAN1/8" = 1'-0"-
12:12 5:12\A1;9'-0"
\A1;14'-0"\A1;15'-0"\A1;4'-0"
MIN. 22 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "C"
ROOF AREA SQ. FT."B"665
ROOF AREA SQ. FT."A"2468
PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
ELEVATION EC2M
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 2468 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 3.29 4.11 4.24 50.00 10 0
AT EAVE 4.94 4.11 4.24 50.00 0 61.00
TOTAL (MIN)8.23 8.23 8.47 100.00
3
HIGH -
RIDGE VENT 3.29 4.11 4.13 49.75 0 0 33.00
AT EAVE 4.94 4.11 4.17 50.25 0 60.00
TOTAL (MIN)8.23 8.23 8.29 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ELEVATION EC2M
ROOF AREA "B"SQ FTG 665 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.89 1.11 1.27 49.06 3 0
AT EAVE 1.33 1.11 1.32 50.94 0 19.00
TOTAL (MIN)2.22 2.22 2.59 100.00
3
HIGH -
RIDGE VENT 0.89 1.11 1.13 48.80 0 0 9.00
AT EAVE 1.33 1.11 1.18 51.20 0 17.00
TOTAL (MIN)2.22 2.22 2.31 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
1x4 Trim Installed around All Windows on Sides and Rear
02/25/20
William Hohlt