Loading...
HomeMy WebLinkAboutA000.31900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2020 Zach Bittner08/04/2014 Right Skyview 2056.300.00.CPM LOT 01 01/08/2020 PLOTTED: January 24, 2020 / Kamlesh Bisht / 2056-SKYVIEW-CZ-BASE-EL-EC2M.DWG A3-EC2M 3SB.1Euro Country 2M3 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleSCALE:FRONT ELEVATION1/4" = 1'-0"- 1212 1212 1212 1212 12121212 STONE SILL, PER SPEC. ROOF SHINGLES, PER SPEC 6" RAKE BOARD, PER SPEC STONE VENEER, PER SPEC (2) FYPON # LV18X30\POR APPROVED EQUAL FRIEZE, PER SPEC TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATE WINDOW HEAD HGT. WINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR 8" TRIM, PER SPEC 6" FASCIA BOARD, PER SPEC ROOF SHINGLES, PER SPEC 6" CORNER BOARD, PER SPEC 10" FRIEZE, PER SPEC 1212 1212 12 5 2040 FX BLACKED OUT WINDOWS CL-02AD 2.1SIMILAR STONE SILL, PER SPEC HORIZONTAL SIDING, PER SPEC FYPON #BKT30X30X8, OR APPROVED EQUAL FYPON #LV8X24, OR APPROVED EQUAL \A1;4'-6" \A1;9'-1{\H0.750000x;\S1#8;}" \A1; \A1;8'-2{\H0.750000x;\S7#8;}" \A1; \A1;8'-1{\H0.750000x;\S1#8;}" \A1; \A1;7'-2{\H0.750000x;\S7#8;}" \A1; \A1;7'-2{\H0.750000x;\S7#8;}" \A1;\A1;4'-2{\H0.750000x;\S7#8;}" SMOOTH PANNEL, PER SPEC MIN. 6" CLEARANCE BELOW SILL FOR FLASHING, PER DETAIL SCALE:REAR ELEVATION1/8" = 1'-0"- \A1;7'-8"\PHDR. HGT.\A1;7'-8"\PHDR. HGT. 1212 1212 12121212 MASONRY WAINSCOT \A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF FOUNDATIONTOP OF FLOOR TOP OF PLATETOP OF FLOOR TOP OF PLATE ROOF SHINGLES, PER SPEC HORIZONTAL SIDING, \PPER SPEC SCALE:LEFT ELEVATION1/8" = 1'-0"- 128128 128 124 MASONRY WAINSCOT SCALE:RIGHT ELEVATION1/8" = 1'-0"- 128128 128 \pxql;8" TRIM, PER SPEC.\pxql;6" TRIM, PER SPEC. 12:12 12:12 12:12 4:12 8:12 8:12 4:12 \A1;1'-0"\PTYP. 12:1212:12 12:12 8:12 8:12 12:12 8:12 12:1212:12 12:1212:1212:1212:12 8:128:12 \A1;7'-0"\A1;11'-0"\A1;10'-8{\H0.750000x;\S1#8;}" MIN. 303 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"4:12 SCALE:ROOF PLAN1/8" = 1'-0"- 12:12 5:12\A1;9'-0" \A1;14'-0"\A1;15'-0"\A1;4'-0" MIN. 22 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "C" ROOF AREA SQ. FT."B"665 ROOF AREA SQ. FT."A"2468 PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION ELEVATION EC2M ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2468 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.29 4.11 4.24 50.00 10 0 AT EAVE 4.94 4.11 4.24 50.00 0 61.00 TOTAL (MIN)8.23 8.23 8.47 100.00 3 HIGH - RIDGE VENT 3.29 4.11 4.13 49.75 0 0 33.00 AT EAVE 4.94 4.11 4.17 50.25 0 60.00 TOTAL (MIN)8.23 8.23 8.29 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION EC2M ROOF AREA "B"SQ FTG 665 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.89 1.11 1.27 49.06 3 0 AT EAVE 1.33 1.11 1.32 50.94 0 19.00 TOTAL (MIN)2.22 2.22 2.59 100.00 3 HIGH - RIDGE VENT 0.89 1.11 1.13 48.80 0 0 9.00 AT EAVE 1.33 1.11 1.18 51.20 0 17.00 TOTAL (MIN)2.22 2.22 2.31 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 1x4 Trim Installed around All Windows on Sides and Rear 02/25/20 William Hohlt