Loading...
HomeMy WebLinkAboutS101.0N30685066 D01D01 D01D01 D01D01 D01D01 D01D01 9'-1 " 1 1 '-6" 2'-5" 20'-7" 23' 4'-1 "6'-1 " 1 '-4"4'-8"4'-5" 20'-7"2'-5" 23' 1 1 '-6"9'-1 " 3'-7"6'-1" 3'-4" 13'2' 15'9'-3"13'-6" 16'-8"20'-2" X 1 2'-7" 254 SQ FT 4 A4 4 A4 5 A4 5 A4 6 A4 6 A4 SUN ROOM N1 1 : 1 2 4 : 124 : 1 2 4 : 1 2 4 : 12 4 : 12EXISTING ROOF PLANE TO REMAIN NEW ROOF EDGE TO ALIGN WITH BOTH EXISTING ROOF PLANES FOR SUFFICIENT DRAINAGE, NEW GUTTER TO BE ADDED AS REQUIRED. (V.I.F.) NEW ROOF EDGE TO ALIGN WITH BOTH EXISTING ROOF PLANES FOR SUFFICIENT DRAINAGE, NEW GUTTER TO BE ADDED AS REQUIRED. (V.I.F.)12'-11"2' 16'-8"20'-7"2'-6" EXISTING SLAB ON GRADE EXISTING SLAB ON GRADE NDOOR SCHEDULE NUMBER QTY WIDTH HEIGHT DESCRIPTION HEADER ROOM NAME D01 5 70 1 /2 " 96 " MULLED UNIT 2X6X71 1 /2" (2) SUN ROOM FLOOR PLAN - SUNROOM SCALE: 1/4"=1' 3 A2 3 A2 A2SUN ROOM ADDITION & BATH MODIFICATIONOWNER:LAWRENCE RESIDENCEPROPOSED PLANS AMY LAWRENCE PROJECT NUMBER: 20002 DRAWN BY: CC DRAWING DATE: 2/4/2020 REVISION & DATE: SCALE: AS SHOWN 10910 PLEASANT VIEW DR.CARMEL, IN 46033 ROOF PLAN - SUNROOM SCALE: 1/4"=1' 2 A2 2 A2 FOUNDATION PLAN - SUNROOM SCALE: 1/4"=1' 1 A2 1 A2 FLOOR PLAN NOTES: 1. ALL EXTERIOR DIMENSIONS ARE TO THE MAIN LAYER. DIMENSIONS TO OPENINGS ARE TO THE CENTERS. INTERIOR DIMENSIONS ARE TO THE STUDS. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). GENERAL NOTES: THIS PLAN SET, COMBINED WITH THE BUILDING CONTRACT, PROVIDES BUILDING DETAILS FOR THE RESIDENTIAL PROJECT. THE CONTRACTOR SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. CONTRACTOR SHALL BE RESPONSIBLE AND BEAR ANY FINES OR PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS. INSURANCES SHALL BE IN FORCE THROUGHOUT THE DURATION OF THE BUILDING PROJECT. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). ALL TRADES SHALL MAINTAIN A CLEAN WORK SITE AT THE END OF EACH WORK DAY. PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. 02/26/20 William Hohlt