Loading...
HomeMy WebLinkAboutL500 - SITE DETAILS1 1/2" 2 1 2" Compacted Subgrade Bituminous Binder #8 Tack Coat Bituminuous Surface #11 Compacted Aggregate #53 8" ASPHALT PAVEMENT (Parking and Drives) Not to Scale 112" 5 1/2" Compacted Subgrade Bituminous Binder #8 Tack Coat Bituminuous Surface #11 Compacted Aggregate #53 12"HEAVY-DUTY ASPHALT PAVEMENT Not to Scale CONCRETE PAVEMENT Not to scale 4,000 psi Fiber Reinforced Concrete, See Specifications Varies (See Plan Sheets) NOTES: 1. Control joints, expansion joints and edges of sidewalks indicated as hand-tooled shall be dressed after each finishing operation. 2. Provide expansion joints at intersection with another sidewalk, beween walks and building slabs, and at other points as indicated on the drawings. 3. Refer to plan drawings for locations of control and expansion joints. Compacted Subgrade 4" Compacted Crushed Stone Finish Grade 4"Varies (See Layout Plan) Compacted Subgrade Compacted #53 Aggregate 4,000 psi Fiber Reinforced CIP Concrete 8"HEAVY DUTY CONCRETE Not to Scale8" CONCRETE JOINTING Not to Scale Straight, true sawn joint #5 smooth bar, 12" long, 18" o.c., centered in slab, grease one end SAWN CONTROL JOINT EXPANSION JOINT 3/8" deep, typ Heel-grade sealant, Refer to Specs. 1/8" r. TOOLED CONTROL JOINT As indicated on plan drawings. Place expansion joints where concrete pours meet and anywhere concrete patching is required. As indicated on plan drawings. Continue to wall face in all applicable conditions. Brush out marks from trowel on either side of joint, leaving only the joint scored smooth. NOTE: Expansion joint material shall be "Zip-Strip" expansion material with removable cap by Greenstreak or approved equal. 3/8" tooled joint 1/4" 3/8" 1" 1/3 slab thickness PAVEMENT AT BUILDING THRESHOLD Scale: 1" = 1'-0" 3'-0"4"Refer to Detail 7/L-501 for Dowels in Concrete @ Threshold Detail Adjacent Hardscape, Refer to Plan 6"45°6" 1 4"/Ft. Slope NOTES: 1. Control joints shall be cut 1 4" depth of total thickness of slab. 2. Fiber additive: Virgin nylon fibers, 3 4" length, Nycon by Nycon Inc., or Forta Nylon by Forta Corporation, added at the batch plant at 1 lb. per cu. yd. of concrete. Concrete with Fiber Additive Compacted Aggregate #53 Compacted Subgrade1/4" max.NOTE: Turn down concrete and dowel at all threshold conditions, where new concrete abuts existing slabs, and at proposed stairs and walls. 4,000 p.s.i. concrete w/limestone aggregate & 5% air entrapment, reinforced with synthetic fibers. Refer to Specifications. Transverse medium broom finish. 1 2" dia. smooth dowel, 12" long, 18" o.c., centered in slab, sleeve one end. 1/2" wide sealed expansion joint Adjacent building slab or face of wall Drill 6" into existing slab; grout solid.4"3" 4" 1'-0" DOWELS IN CONCRETE @ THRESHOLD Scale: 1"=1'-0" 6" 6"1'-0" 45°6" 6"4"1" Rad. Control Joint 1 4"/Ft. Slope Top of Pavement Concrete with Fiber Additive Compacted Aggregate #534" Compacted Subgrade NOTES: 1. Curb shall have 12" expansion joints at 40'-0" max, control joints at 8'-0" max. unless otherwise noted. 2. Control joints shall be cut 14" depth of total thickness of slab. 3. Fiber additive: Virgin nylon fibers, 3 4" length, Nycon by Nycon Inc., or Forta Nylon by Forta Corporation, added at the batch plant at 1 lb. per cu. yd. of concrete. INTEGRAL CONCRETE CURB & WALK Scale: 1"=1'-0" 1 2 3 4 8 6 7 5 9 4'-0", refer to manufacturer recommendations 4'-0" min., refer to manufacturer recommendations4,000 psi C.I.P. Concrete Ground Sleeve Sand Wedges Base Plate and 18" long Ground Spike @ 3/4" dia. 6" Porous Fill FLAGPOLE FOOTING Scale: 1" = 1'-0" Expansion Joint, typ. w/ Sealant Factory Collar Flagpole, See Specs. 3'-0", refer to manufacturer recommendations 8" 1% Slope, typ. BIKE RACK Scale: 1/2" = 1'-0" FINISH GRADE Bike Rack PLAN 3'-0"2'-10"10"8"6" 3'-0"1'-10" SECTION: EMBEDDED #2 Stone Subgrade 4,000 psi concrete standard concrete pavement profile Bike rack 3 8" anchor rod, provided Concrete Pavement2' min clear2' min clear11 10 POST CURB Scale: Not to scale CONCRETE SIDEWALK Scale: Not to scale12 02/27/20