HomeMy WebLinkAboutL500 - SITE DETAILS1 1/2"
2 1
2"
Compacted Subgrade
Bituminous Binder #8
Tack Coat
Bituminuous Surface #11
Compacted Aggregate #53 8" ASPHALT PAVEMENT (Parking and Drives)
Not to Scale
112"
5 1/2"
Compacted Subgrade
Bituminous Binder #8
Tack Coat
Bituminuous Surface #11
Compacted Aggregate #53 12"HEAVY-DUTY ASPHALT PAVEMENT
Not to Scale
CONCRETE PAVEMENT
Not to scale
4,000 psi Fiber Reinforced
Concrete, See Specifications
Varies (See Plan Sheets)
NOTES:
1. Control joints, expansion joints and edges of sidewalks indicated as
hand-tooled shall be dressed after each finishing operation.
2. Provide expansion joints at intersection with another sidewalk, beween
walks and building slabs, and at other points as indicated on the drawings.
3. Refer to plan drawings for locations of control and expansion joints.
Compacted Subgrade
4" Compacted Crushed Stone
Finish Grade
4"Varies (See Layout Plan)
Compacted Subgrade Compacted #53 Aggregate
4,000 psi Fiber Reinforced CIP Concrete
8"HEAVY DUTY CONCRETE
Not to Scale8" CONCRETE JOINTING
Not to Scale
Straight, true sawn joint
#5 smooth bar, 12" long, 18" o.c.,
centered in slab, grease one end
SAWN CONTROL JOINT
EXPANSION JOINT
3/8" deep, typ
Heel-grade sealant, Refer to Specs.
1/8" r.
TOOLED CONTROL JOINT
As indicated on plan drawings. Place
expansion joints where concrete pours meet
and anywhere concrete patching is required.
As indicated on plan drawings. Continue to
wall face in all applicable conditions.
Brush out marks from trowel on either side of
joint, leaving only the joint scored smooth.
NOTE:
Expansion joint material shall be "Zip-Strip"
expansion material with removable cap by
Greenstreak or approved equal.
3/8" tooled joint
1/4"
3/8"
1"
1/3 slab thickness
PAVEMENT AT BUILDING THRESHOLD
Scale: 1" = 1'-0" 3'-0"4"Refer to Detail 7/L-501 for Dowels
in Concrete @ Threshold Detail
Adjacent Hardscape,
Refer to Plan
6"45°6"
1 4"/Ft. Slope
NOTES:
1. Control joints shall be cut 1 4" depth of total thickness
of slab.
2. Fiber additive: Virgin nylon fibers, 3 4" length, Nycon
by Nycon Inc., or Forta Nylon by Forta Corporation,
added at the batch plant at 1 lb. per cu. yd. of concrete.
Concrete with Fiber Additive
Compacted Aggregate #53
Compacted Subgrade1/4" max.NOTE:
Turn down concrete and dowel at all
threshold conditions, where new
concrete abuts existing slabs, and at
proposed stairs and walls.
4,000 p.s.i. concrete w/limestone aggregate & 5%
air entrapment, reinforced with synthetic fibers.
Refer to Specifications. Transverse medium broom
finish.
1 2" dia. smooth dowel, 12" long, 18" o.c., centered
in slab, sleeve one end.
1/2" wide sealed expansion joint
Adjacent building slab or face of wall
Drill 6" into existing slab; grout solid.4"3" 4" 1'-0"
DOWELS IN CONCRETE @ THRESHOLD
Scale: 1"=1'-0"
6" 6"1'-0" 45°6"
6"4"1" Rad. Control Joint
1 4"/Ft. Slope
Top of
Pavement
Concrete with Fiber Additive
Compacted Aggregate #534" Compacted Subgrade
NOTES:
1. Curb shall have 12" expansion joints at 40'-0" max,
control joints at 8'-0" max. unless otherwise noted.
2. Control joints shall be cut 14" depth of total thickness
of slab.
3. Fiber additive: Virgin nylon fibers, 3 4" length, Nycon
by Nycon Inc., or Forta Nylon by Forta Corporation,
added at the batch plant at 1 lb. per cu. yd. of concrete.
INTEGRAL CONCRETE CURB & WALK
Scale: 1"=1'-0" 1
2
3
4
8
6
7
5
9
4'-0", refer to manufacturer recommendations 4'-0" min., refer to manufacturer recommendations4,000 psi C.I.P. Concrete
Ground Sleeve
Sand
Wedges
Base Plate and 18" long
Ground Spike @ 3/4" dia.
6" Porous Fill
FLAGPOLE FOOTING
Scale: 1" = 1'-0"
Expansion Joint, typ. w/
Sealant
Factory Collar
Flagpole, See Specs.
3'-0", refer to manufacturer recommendations
8"
1% Slope, typ.
BIKE RACK
Scale: 1/2" = 1'-0"
FINISH
GRADE
Bike Rack
PLAN
3'-0"2'-10"10"8"6" 3'-0"1'-10"
SECTION: EMBEDDED
#2 Stone
Subgrade
4,000 psi concrete
standard concrete
pavement profile
Bike rack
3
8" anchor rod, provided
Concrete Pavement2' min clear2' min clear11
10
POST CURB
Scale: Not to scale
CONCRETE SIDEWALK
Scale: Not to scale12
02/27/20