Loading...
HomeMy WebLinkAboutIA001 GENERAL NOTES, PARTITION TYPES & SCHEDULESRELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: OZ/Z8I2O ROOF DECK LINE METAL CLOSURE ANGLE SEALEO WITH FIREPROOF SEALANT BRACE SUSPENDED CEILING TO STRUCTURE ABOVE SUSPENDED AGOUSTICAL GEILING TLLE "L" MOULDING ON BOTH SIDES OF WALL AT CEILING LINE 6" METAL STUDS, 20 GAUGE AT i6" O C. WITH 5/8" TVPE "X" GYPSUM BOARD BOTH SIDES. (TO BE CONSTRUCTED TO MEET 1 HOUR FIRE RATMG IN ACCORDANCE WITH GVP. A550Q FIRE RESISTIVE DESIGN MANUAL LATEST EDITION) BASE - SEE SCHEDULE FOR SPEQFICATIONS � 1 HOUR FIRE PARTITION (UNINSULATED� SCALE:314"=1'-0" � � � OF MULLION/ ��OF PARTITION Iy/6Y110[Hr�ll� bIHqr�qlll�R�]J 2" WIDE DOUBLE SIDED FOAM TAPE(CENTER)FORSOUNO SEAL 0.EAR SILICONE CAULK BOTH SIDES TRIM TEX VINVL FAST CAP SCHEDULED PARTITION NOTE DO NOT MECHANICALLV FASTEN STUDS TO E%ISTING WINDOW MULLION(5) 2 PARTITION AT WINDOW MULLION SCALE: 314"=1'-0" �� � � • � � DOOR TYPES SEESCHEO �a 0 x y TVPE Nt SOLID WOOD FLUSHDOOR $EESCHEO w � TYPE ri2 SOLID WOOD FWSH �OUBLE DOOR FRAME TYPES sEEscHEo �� w x U w TVPE ki HOLLOW METAL HARDWARELEGEND DEMOLITION NOTES A THE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARV PARTITIONS AND TEMPORARV DOORS AS INDICATED ON THIS �EMOLITION PLAN, OR AS DEEMED NECESSARV BV THE ARCHITECT AND OWNER. THEV SHALL BE MAINTAMED AND REPAIRED IMMEDIATELV IF ANY DAMAGE OCCURS. THESE DOOR ARE TO AVOID MIGRATION OF DUST INTO THE ADJOINING AREAS. B GENERALCONTRACTORTOVERIFYDUCTWORKORPIPINGPENETRATIONSTHROUGHWALLSA80VE CEILWG. IF PENETRATIONS OCCUR AND DUCTWORK OR PIPING IS TO BE REMOVED OR RE�OCATED, RLL IN OPENINGS TO BE RUSH W ITH AND OF THE SAME MATERIAL AS THE SURROUNDING WALL. C MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER SUITABLE TO ACCEPT NEW SPEQFIED FINISHESANDORSIIRFACES. REFERTOARCHITECTURALPLANS,SPECIFICATIONS,ANDDETAILSFOR SPEqFIC INFORMATION REGARDINGAPPLICATION OF NEW MATERIAL. ARCHITECTURAL NOTES A ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS AND STANDARD$ INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDING CODE. THE INDIANA CODES, THE INDIANA FlRE CODES, THE AMERICANS W ITH DISABILITIES ACT (ADA). INTERNATIONALBUILDINGCODE,ANDAPPLICABLETRA�ESTANDARDS. ALLAPPLICABLERULESAND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS. B THE CONTRACTOR IS RESPON518LE FOR FIEL� VERIFVING ALL CONDITIONS AND DIMENSIONS PRIOR TOTHESTARTOFWORK. REPORTANVDISCREPANqESTOTHEARCHITECT/DESIGNERIMMEDIATELV. C THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS RE�UIRED FOR COMPLETION OF THIS PROJECT. D ALL WORK IS TO BE COORDINATEO BV THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SVSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCW DING SERVICE REQUIREMENTS OF THE OWNERS EEE. E ALLDIMENSIONSARESHOWNONTHEDRAWINGS. ANVDIMENSIONSNOTSHOWNORDEEMED pUESTIONABLEARETOBEVERIFIEDWITHTHEARCHITECT/DESIGNER. DONOTSCALE�IMENSIONS ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF GVPSUM BOARD, MASONRV/CONCRETE WALLS, OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE. F CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL THAT HAS BEEN REVIEWED, APPROVED, AND THE CONTRACTOR COORDINATION HAS BEEN PERFORMED. G DURING THE ENTIRE PERIOD OF CONSTRUCTION, ALL EXISTING EXITS, EXIT LIGHTING, FIRE PROTECTIVE OEVICES, AND ALARMS SHALL BE CONTINUOUSLV MAINTAINED. H FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 6" FROM ADJACENT PERPENDICULAR PARTITIONS, UNLESS OTHERWISE NOTED. I ALL FlNISH CARPENTRV IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A W.I. STANDARDS, PREMIUM GRADE. J ALL FIRE EXTINGUISHER CABMET LOCATIONS ARE TO BE COORDINATED WITH THE CONTRACTOR, DESIGNER AND THE LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION. K CONTRACTOR(S)SHALLPROVIDEALLNECESSARVLABOR,MATERIALS.ANDE�UIPMENTFORTHE WORK IN THESE DOCUMENTS, UNLESS QEARLV NOTED "NOT IN CONTRACT" (N.I.C.). EXISTING WORK ADJACENT TO OR IN THE AREA OF NEW WORK SHALL BE PROTECTED BV ALL SUITABLE MEANS NECESSARV TO PREVENT OR MINIMIZE �AMAGE. WHERE EXISTING WORK IS TO BE REMOVED OR ALTERED,RESTOREAOJACENTFINISHTOORIGINALCONDITION. EXTEN�/REFINISHALLFRAMES, BASE, AND TRIM WHERE CUTTING HAS EXPOSE� ANV UNFlNISHED SURFACES. REPAIR ANV DAMAGE TO EXISTIN6 WORK AND RESTORE TO ORIGINAL CONDITION. L CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES FREE OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITV OF THE CONTRACTOR AN� SHALL BE STORED IN A LOCATION APPROVED BV THE LANOLORD. M ALL PLUMBING ITEMS ANDIOR EQUIPMENT ITEMS ARE TO BE COORDINATED AND VERIFlED WITH INTERIOR ELEVATIONS PRIOR TO ROUGH-IN. ANY DISCREPANCIES SHALL BE COORDINATE� WITH THE DESIGNER. N COORDINATED WITH OWNERAND FACILITV STAFF PROJECT PHASING TO MINIMIZE DISRUPTION OF EXISTING FACILITV SERVICES. PHASING TO INCW DE ASSUR4NCE FOR CLEAN AIRFLOW, WRITTEN NOTIFlCATION OF INTERRUPTIONS, AND COMMUNICATION AUTHORITV. CONTRACTOR, OWNER, AND FACILITY STAFF TO PLAN FOft PROCEDURES ON THE EFFECTS OF NOISE AND VIBRATION ON HUMAN HEALTH AND SAFETV. THE RENOVATED AREAS SHALL BE ISOLATED FROM THE OCCUPIED AREAS DURING ALL PHASES OF CONSTRUCTION USING AIRTIGHT BARRIERS, AND EXHAUST AIR FLOW SHALL BE SUFFICIENTTO MAINTAIN NEGATIVEAIR PRESSURE IN THE CONSTRl1CTION ZONE. 0 SUBMITTHEREQUIREDNUMBEROFSUBMITTALSFORDESIGNERREVIEWANOAPPROVALPLUSONE EXTRA COPV FOR DESIGNERS RECORDS. SET p1 3 HINGES 1 LEVERHANDLESTOREROOMLOCK 1 ELECTRIC STRIKE 1 CARDREADER 1 DOOR POSITION SWITCH 1 MOTION SENSOR 1 SURFACE CLOSER, PULL SIDE 1 FLOOR STOP 3 SILENCERS SET p2 ] HINGES 1 ELECTRIC HINGE (INACTNE LEAF) 1 LEVER HANDLE STOREROOM LOCK (ACTNE LEAF) 1 CARDREADER 2 DOOR POSITION SWITCHES 1 MOTION SENSOR 2 SURFACE CLOSER$ PULL SIDE � COOROINATOR 2 FWSHBOLTSQNACTIVELEAF) 1 DUSTPROOFSTRIKE(INACTNELEAF) 1 ASTRAGAL (ACTIVE LEAF) 2 WALLSTOPS 2 SILENCERS DOOR SCHEDULE DOOR SIZE NO. TYPE FINISH ly:7fl�l� . �f73L►T7:� I�IJFYi�l:iilll�[tl��19a ��I�IFY]I 3•O••�T �•• �13/4 � A � PRE-FIN� 2� � 1 � PAINT � 20 � 1 � 630 �H,K E% � E% � EX � EX � E% �- � EX � PAINT �- � 2 � 630 E% � E% � EX � EX � E% �- � EX � PAINT �- � 2 � 630 10 I6'-0"I�'-0"I�-314"IB �PRE-FIN�- �1 �PAINT �- �2 �630 13 6'-0" ]'-0" 1-314" B PRE-FW 20 1 PAINT 20 2 630 14 6'-0" ]'-0" 1-314" B PRE-FIN - 1 PAINT 2 630 DOORNOTES A. GENERAL CONTRACTOR TO COORDINATE KEVING WITH OWNER/rENANT. B. ALL TENANT LOCKSETS SHALL BE KEVED TO A SUITE MASTER KEY SYSTEM. G ALL HARDWARE SHALL BE ADA COMPLIANT. D. FURNISHANDINSTALLLOCKSETSWITHMANUFACTURER'SSTANDARDCVLINDERUNLESS OTHERWISE NOTED. E CONTRACTOR TO FURNISH AND INSTALL ALL HARDWARE SETS COMPLETE WITH STRIKE BOXES AT ALL NEW DOOR FRAMES, UNLESS OTHERWISE NOTED. E SECURITV ACCESS CONTROL DEVICES SHALL BE FURNISHED AND MSTALLED BV TENANT'S VENDOR. G. ALL SECURITV ACCESS CONTROL DEVICES SHALL BE "FAIL SAFE" UNLESS OTHERWISE NOTED. H. PROVIDE UL RATED HARDWARE ON ALL FIRE RATED �OORS. I. MODIFVEXISTINGDOORFRAMEANDHARDWAREASREpUIREDTOACCOMMODATEHAR�WARE SET k2 J. RIGHTHANDREVERSEACTNE K. ALL NEW DOORS, FRAMES AND HARDWARE TO MATCH EXISTING. L RIGHTHANDACTIVE M. NON-REMOVABLEPW(NRP)HINGES REFLECTED CEILING NOTES A PROVIDEFIREDAMPERSATFIRE-RATEDPARTITIONSASREpUIREDPERAPPLICABLEBUILDWG CODES. B CEILWGINALLAREASSHALLBEINSTALLEDINSTRICTACCORDANCEWITHMANUFACTURER'S SPEQFICATIONS, AND ALL APPLICABLE BUILDING CODES. C MECHANICALCONTRACTORSHALLBERESPONSIBLEFORALLDUCTWORK,SUPPLVANDRETURNAIR AND THERMOSTATS. COORDINATE ALL ELEMENTS OF THE HVAC SYSTEM TO PROVIDE A COMPLETELV BALANCED AND EFFlCIENT HEATING AND COOLING SVSTEM. � HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED WITHIN DEMISED SUITE VERIFV AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED. E MECHANICALCONTRACTORSHALLVERIFVWORKINGCONDITIONOFALLEXISTINGTHERMOSTATS, VAV BOXES, EXHAUST FANS, AND ANV OTHER DEVICE DIRECTLY RELATED TO THE HVAC SVSTEM. CONTRACTOR TO NOTIFV ENGWEER/�ESIGNER IMMEDIATELV UPON DISCOVERV OF DEFECTIVE DEVICE. ELECTRICAL NOTES A THEELECTRICAL CONTR4CTORISTOPROVIOEALLREpUIREDLABOR,MATERIALS,EQWPMENT,AND CONTRACTORS SERVICES NECESSARV TO COMPLETE INSTALLATION OF SVSTEMS REQUIRED W FULL CONFORMITV WITH APPLICABLE CODES AND ORDINANCES. THE FlNISHED JOB SHALL BE FUNCTIONAL AND COMPLETE W EVERV DETAIL INCLUDING ANV AND ALL SUCH ITEMS FOR A COMPLETE SVSTEM. 8 ALLMATERIALSANDWORKMANSHIPSHALLMEETALLAPPLICABLESTATEAN�LOCALCODES, ORDINANCES, UTILITV COMPANV REGULATIONS AND NATIONALLY ACCEPTED CODES AN� STANDARDS. THE ELECTRICAL CONTRACTOR W ILL BEAR ALL COSTS ARISING IN CORRECTING ANV NON COMPLIANCE WITH THE REQUIREMENTS OF APPLICABLE CODES. C CONTRACTORTOSUPPLYANDWSTALLALLELECTRICALWIRING,WCWDINGRUNSFROMJUNCTION BOXTOINDIVIOUALWORKSTATIONUNITS. CONTRACTORTOSUPPLVPLENUMRATEDBOXESAND PULLS AS REpUIRED TO ACCOMMODATE TENANT'S TELEPHONE, DATA ANO SECURITV �EVICES. L MITSCH D E 5 I G N 200 S. Rangeline Rtl. I Suite 226 Carmel, Intliana 46032 317.5732222 www.m itschdesign. com r1 W ^ 1� � a W � W � r1 � � O O � � � � z � � z U� � � 2W w J �M � � 0 J = Q Q H W Z O J Q m � O Z '^ Z U � w UZ� ~ r a' Q Q�v� p° V ` ............. "',f-- � ;. ��srEq , T= '�• �: eE N0. f�•': Z * � aii�sooiso i * � SiFiE Of _ •�'•.�ixoiax;.:'� ��� �'�R�li � L�i,�,� ;�J°� \ a� �r w r Z�N �Z~ � WUd' K¢W aan rvsmaiairvn_woausaF AurHoasHiv Fir�o iN A*ANoie�e me�i�i� o...Preessio� oose MOEsicN. auyaieHnvaesEaveo�E Eee>�r oa �se GENERALNOTES, PARTITION TYPES AND SCHEDULES I �O 0�