HomeMy WebLinkAboutIA101 CONSTRUCTION PLANRELEAS Su6jec� of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: OZ/Z8I2O CONSTRUCTION LEGEND NOTINCONTRACT EXISTING WALL OR ITEM TO REMAIN NEW 1-HR RATED PARTITION REFER TO 1 /IA001 GENERAL CONSTRUCTION NOTES A FURNISH AN� INSTALL NEW HORRONTAL BLINDS TO MATCH EXISTIN6 AT ALL EXTERIOR WINDOWS WHERE EXISTING BLINDS WERE DETERMINED TO BE DAMAGED. COORDINATEALL WORK WITH BUILDING OWNER. B. ALL E%ISTING WALL FINISHES TO REMAIN. PATCH, REPAIR, AND REPAINT ALL WALLSAFFECTED BVDEMOLITIOWCONSTRUCTIONASREQUIRED. PAINTTOMATCHEXISTINGFROMCORNERTO CORNER,UNLESSOTHERWISENOTED. C. PROVIDEBLOCKINGINWALLSTOACCOMMODATEALLCASEWORKANDWALLMOUNTED EQUIPMENL D. REFERTODRAWWGG001FORPARTITIONTYPESANDDOORANDHARDWARESCHEouLES. E DOORS NOT INDICATED BV DOOR NUMBER DESIGNATION ARE EXISTING. F ALLWALLSPROVIDEDTOBERNISHEDTOLEVEL4. G. IF �UCTWORK INTERFERES W ITH DECK-TO-DECK PARTITIONS, OFFSET PARTITION HEAD AROUND DUCTWORK. H. EXISTINGFLOORINGTHROUGHOUTAREAOFWORKTOREMAIN,UNLESSOTHERWISENOTED. PATCH ALL CARPETED AREAS AFFECTED BV DEMOLITION/CONSTRUCTION WITH CARPET SALVAGED FROM DEMOLITION PHASE. I. ALL WALLS TO RECEIVE WALL BASE TO MATCH EXISTING UNLESS OTHERWISE NOTED. J. CONTROLJOINTS SHALL BE INSTALLED IN GVPSUM 80ARD PARTITIONS EXCEEDING 30 LWEAR FEETINANUNINTERRUPTEDPLANE WHEREPOSSIBLEALIGNCONTROLJOINTWITHVERTICAL EDGE OF DOOR FRAMES. WHERE A CONTROL JOINT OCCURS IN A RRERATED SVSTEM, BLOCKING SHALL BE PROVI�ED BEHIND THE CONTROL JOINT BY USING A BACKING MATERIAL SUCH AS 5/8" GVPSUM BOARD, MMERAL FIBER, OR OTHER TESTED EQUIVALENT. K. ALL KEYNOTES INDICATED ON THIS PLAN AS "TYPICAC' ARE TO BE CONSIDERED AS SHOWN AT ALL OTHER SIMILAR CONDITIONS WHETHER NOTED OR NOT. 0 CONSTRUCTION KEYNOTES 1. EXISTING PARTITION TO BE MODIFIED IF/AS REpUIREDTO MATCH PARTITION TVPE 1. 2 EXISTING DECK TO DECK PARTITION TO REMAIN. CONTRACTOR TO CONFIRM EXISTING STUDS AREAMINIMUM25GAUGEANDRUNATLEAST2a"O.G FURNISHANDINSTALLNEWSIB"TVPE"x" GWB OVER EXISTING GWB THIS SIDE OF PARTITION WITH 7" N0.6 DRVWALL SCREWS AT EACH STUD. 3. EXISTINGiHOURRATED�EMISINGWALLTOREMAIN.PATCH/REPAIR/MODIFVIF/ASREQUIREDTO MAINTAIN 1 HOUR RATING. 4. FURNISH AN� MSTALL NEW CANOPY TO MATCH EXISTING. COORDINATE ALL WORK WITH BUILDING OWNER. 5. TOP OUT EXISTING PARTITION TO DECK UTILIZING 2� GA. 3-5/8" (MATCH EXISTING) METAL STUDS, i6"O.G FURNISHANDINSTALLADDITIONALSUPPORT/�IAGONALBRACINGSECUREDTOOECK ABOVE WITH DEFLECTION TRACK AS REQUIRED. 6. PATCH, REPAIR, AND SCRAPE ALL EXISTWG ADHESNES OFF OF EXPOSE� CONCRETE IN THIS ROOM/AREA FURNISH AND INSTALL NEW CONCRETE SEALANT. ]. FURNISHANOINSTALLNEWTRANSITIONSTRIPTOMATCHEXISTINGBETWEENALLCARPETAND EXPOSED CONCRETE LOCATIONS. 8. INDICATES FIRE EXTINGUISHER CABINET RELOCATED FROM �EMOLITION PHASE. & EXISTINGVINVLCOMPOSITIONTILETOREMAIN. PftOTECTASRE�UIREDDUftINGDEMOLITIONI CONSTRUCTION. L MITSCH D E 5 I G N 200 5. Rangeline Rtl. I Suite 226 Carmel, Intliana 46W2 317.5732222 www.m itschdesign. com V_1J 1� W ^ 11 � a W �'^ V1 w � � � O � � U � � O � � � z Q Z w � � � r 2W � J �M Q o W �� =QQ wZ ZvQ Q w � � O Z Z�� V z� r a' Q � U �P' V ` ............. �''F" � �. ��srEq , T= '�• �: eE N0. f�•': Z * ' ������ : * � SiFiE Of _ ••�•.�iNp::N�.:�• �\� '���CH � T�E��111\\\ r w U, J H H � m 1 VI w Q V� \ O r a w � ooa U noo �w ^ l/� l/� � - W � � Q Q oo� I o U N O ti � y W Q w�m <rwi�w �� m o z v� OZy ��H Z- d Q w w U a � o � x � rc w �oo aan pnovsHi> Fi.Eo iN q.qo a�N rvsr oaic�rvo�y��PreEssFoi oose MOEsicN. nuyA�eHrs aesEaven Exee>� roa �se. CONSTRUCTION PLAN I A101