HomeMy WebLinkAboutIA101 CONSTRUCTION PLANRELEAS
Su6jec�
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM��_
DATE: OZ/Z8I2O
CONSTRUCTION LEGEND
NOTINCONTRACT
EXISTING WALL OR ITEM TO REMAIN
NEW 1-HR RATED PARTITION
REFER TO 1 /IA001
GENERAL CONSTRUCTION NOTES
A FURNISH AN� INSTALL NEW HORRONTAL BLINDS TO MATCH EXISTIN6 AT ALL EXTERIOR
WINDOWS WHERE EXISTING BLINDS WERE DETERMINED TO BE DAMAGED. COORDINATEALL
WORK WITH BUILDING OWNER.
B. ALL E%ISTING WALL FINISHES TO REMAIN. PATCH, REPAIR, AND REPAINT ALL WALLSAFFECTED
BVDEMOLITIOWCONSTRUCTIONASREQUIRED. PAINTTOMATCHEXISTINGFROMCORNERTO
CORNER,UNLESSOTHERWISENOTED.
C. PROVIDEBLOCKINGINWALLSTOACCOMMODATEALLCASEWORKANDWALLMOUNTED
EQUIPMENL
D. REFERTODRAWWGG001FORPARTITIONTYPESANDDOORANDHARDWARESCHEouLES.
E DOORS NOT INDICATED BV DOOR NUMBER DESIGNATION ARE EXISTING.
F ALLWALLSPROVIDEDTOBERNISHEDTOLEVEL4.
G. IF �UCTWORK INTERFERES W ITH DECK-TO-DECK PARTITIONS, OFFSET PARTITION HEAD AROUND
DUCTWORK.
H. EXISTINGFLOORINGTHROUGHOUTAREAOFWORKTOREMAIN,UNLESSOTHERWISENOTED.
PATCH ALL CARPETED AREAS AFFECTED BV DEMOLITION/CONSTRUCTION WITH CARPET
SALVAGED FROM DEMOLITION PHASE.
I. ALL WALLS TO RECEIVE WALL BASE TO MATCH EXISTING UNLESS OTHERWISE NOTED.
J. CONTROLJOINTS SHALL BE INSTALLED IN GVPSUM 80ARD PARTITIONS EXCEEDING 30 LWEAR
FEETINANUNINTERRUPTEDPLANE WHEREPOSSIBLEALIGNCONTROLJOINTWITHVERTICAL
EDGE OF DOOR FRAMES. WHERE A CONTROL JOINT OCCURS IN A RRERATED SVSTEM,
BLOCKING SHALL BE PROVI�ED BEHIND THE CONTROL JOINT BY USING A BACKING MATERIAL
SUCH AS 5/8" GVPSUM BOARD, MMERAL FIBER, OR OTHER TESTED EQUIVALENT.
K. ALL KEYNOTES INDICATED ON THIS PLAN AS "TYPICAC' ARE TO BE CONSIDERED AS SHOWN AT ALL
OTHER SIMILAR CONDITIONS WHETHER NOTED OR NOT.
0 CONSTRUCTION KEYNOTES
1. EXISTING PARTITION TO BE MODIFIED IF/AS REpUIREDTO MATCH PARTITION TVPE 1.
2 EXISTING DECK TO DECK PARTITION TO REMAIN. CONTRACTOR TO CONFIRM EXISTING STUDS
AREAMINIMUM25GAUGEANDRUNATLEAST2a"O.G FURNISHANDINSTALLNEWSIB"TVPE"x"
GWB OVER EXISTING GWB THIS SIDE OF PARTITION WITH 7" N0.6 DRVWALL SCREWS AT EACH
STUD.
3. EXISTINGiHOURRATED�EMISINGWALLTOREMAIN.PATCH/REPAIR/MODIFVIF/ASREQUIREDTO
MAINTAIN 1 HOUR RATING.
4. FURNISH AN� MSTALL NEW CANOPY TO MATCH EXISTING. COORDINATE ALL WORK WITH
BUILDING OWNER.
5. TOP OUT EXISTING PARTITION TO DECK UTILIZING 2� GA. 3-5/8" (MATCH EXISTING) METAL STUDS,
i6"O.G FURNISHANDINSTALLADDITIONALSUPPORT/�IAGONALBRACINGSECUREDTOOECK
ABOVE WITH DEFLECTION TRACK AS REQUIRED.
6. PATCH, REPAIR, AND SCRAPE ALL EXISTWG ADHESNES OFF OF EXPOSE� CONCRETE IN THIS
ROOM/AREA FURNISH AND INSTALL NEW CONCRETE SEALANT.
]. FURNISHANOINSTALLNEWTRANSITIONSTRIPTOMATCHEXISTINGBETWEENALLCARPETAND
EXPOSED CONCRETE LOCATIONS.
8. INDICATES FIRE EXTINGUISHER CABINET RELOCATED FROM �EMOLITION PHASE.
& EXISTINGVINVLCOMPOSITIONTILETOREMAIN. PftOTECTASRE�UIREDDUftINGDEMOLITIONI
CONSTRUCTION.
L
MITSCH
D E 5 I G N
200 5. Rangeline Rtl. I Suite 226
Carmel, Intliana 46W2
317.5732222
www.m itschdesign. com
V_1J
1�
W
^
11
�
a
W
�'^
V1
w
�
�
�
O
�
�
U
�
�
O
�
�
�
z
Q
Z
w
�
�
�
r
2W
�
J �M
Q o
W ��
=QQ
wZ
ZvQ
Q w �
� O Z
Z��
V z�
r a'
Q � U
�P' V ` ............. �''F"
� �. ��srEq , T=
'�• �: eE N0. f�•': Z
* ' ������ : *
� SiFiE Of
_ ••�•.�iNp::N�.:�• �\�
'���CH � T�E��111\\\
r
w
U,
J
H
H
�
m
1
VI
w
Q
V�
\
O
r
a
w �
ooa U
noo �w
^ l/� l/� � - W �
� Q Q oo� I
o U
N
O
ti
� y W Q
w�m <rwi�w ��
m o z v�
OZy ��H
Z-
d Q w w U a �
o � x � rc w
�oo aan
pnovsHi> Fi.Eo iN q.qo a�N rvsr oaic�rvo�y��PreEssFoi
oose MOEsicN. nuyA�eHrs aesEaven Exee>� roa �se.
CONSTRUCTION PLAN
I A101