Loading...
HomeMy WebLinkAboutIA251 ELECTRICAL-DATA PLANOFFICE II 103 � OPEN OFFICE 102 8 � 3 ❑ ❑ 0 F i� OFFICE 124 tl i I 1 WORKROOM iaa � �� OFFICE 105 � � ��/ � � nosn � � � � �� I 'H F4' 55),5 �� I � �f _ � 1 '�J.�,��� I � L� BREANROOM � � 101 1 I �% ❑ � �I / ' -.- � � � � _- � � CONFERENCE 1 � J O � � � U 0 LL o � ❑3 F�..r_ F ,.. 0 ,, � 5 COPV/PRINT = 109 7, � � i o OPEN OFFICE 121 � �; \ � � '•. �� � � Y % � � r p � � Y F �� �` � - - I �� �� � � � � � - 'l 0' � � 0 �/'\� �i, oP�norfice y -- � � 123 M � i RELEA5E0 FOR CONSTRIICTI�N � Su6jec� �o compliance with all regula�ions "- of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��. DATE: OZ/Z8/2O OPEN OFFICE � 122 C �Y ! � � e ' 1 i i � � i ��� �� MEN'S 106 WOMEN'S 101 STORAGE 108 / � _� 0 CONFERENCE � 119 — ^ ' � � � zniaeav MAIN SWITCHGEHR 1-1/J" EMT CONDUIT (JJ #2 AW G COPPER (1J #8 AW G COPPER MAIN 2' EMT CON�UIT �a7 a�o nwc coaaea A (1)#4NWGCOPPEF 2�0 NMP 12�I208v PANEL 40 SPACE ]5 KVA TRANSFORMER 02 ELECTRICAL RISER DIAGRAM SCALE: 118" =1'-0" •• • • • • • OPEN OFFICE 110 � � , : 7� � '� n . ;'.. .. ,' ^... ", ._.; � L�� MEN'S �I W i 115 � '1 � _ � �� n STORAGE iia Q E� 118 �II � �I U� OFFICE 118 OFFICE �P � 1 � � � � � � � '� '� `� t `� �30ROBVOLT30� � (TVPICALOFI2) � SERVER 111 �i� �,�` F.ec`" � n I � � � STORAGE 113 � 8 O � ELECTRICAL I DATA PLAN .. . 0 SCALE. 118" =1'-0" N 13 I6 I I� 12 ELECTRICAL/DATA LEGEND NOT IN CONTRACT W' DUPLEXPOWERRECEPTA0.E � DOUBLE DUPLEX POWER RECEPTACLE W DEDICATED DUPLEX RECEPTACLE �� RUSH MOUNTE� RECESSED ROOR POWER RECEPTACLE AND DATA/VOICE OUTLET (SINGLE DEVIGE) � VOICNDATAOUTLET GFI GROUND FAULT INTERRUPTER TV TENANTPROVIDE�TV +pp CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLE �-POa CEILINGMOUNTEDSVSTEMSFl1RNITUREPOWERTOPFEED o-C�i+. CEILING MOUNTED SVSTEMS FURNITURE DATAIVOICE TOP FEED � WALL MOUNTED JUNCTION BOX FOR SVSTEMS FURNITURE POWER BASE FEED � WALL MOUNTE� JUNCTION BOX FOR SVSTEMS FURNITURE DATANOICE BASE FEED GENERAL ELECTRICAL/DATA NOTES A. THE ELECTRICAL CONTR4CTOR SHALL NOTIFV THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE CONTRACT DOCl1MENTS AN� APPLICABLE COOES PRIOR TO CONSTRUCTION. B. ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL E�UIPMENT REQUIREMENTSAS INDICATED ON DRAWINGS OR AS RE�UESTED BV TENANT. VERIFV ACTUAL REQUIREMENTS WITH DESIGNER PRIOR TO INSTALLATION. G ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONEIDATA LOCATIONS AS INOICATED ON PLANS. COMPLETE TELEPHONEIOATA SVSTEMS (MATERIAL AND LABOR) TO BE PROVIDED BV THE TENANT UNLESS OTHERWISE NOTE�. D. ALL SECURITY SVSTEMS TO BE PROVIDED BV TENANT UNLESS NOTED OTHERWISE. E. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING REQUIREMENTS FOR MILLWORK AND CABINETRV W ITH CONTRACTOR AS NECESSARV. F. ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLV AT 18" AF.F. TO CENTERLINE OF OUTLET, UNLESS OTHERWISE NOTED. G. SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL MATCH EXISTING. H. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REOUIRED TO MINIMIZE SOUND TRANSMISSION. I. ADJACENT OUTLETS SHALL 8E GANGED WHEN POSSIBLE. IF THEV CANNOT BE GANGED, THEV SHALL BE INSTALLED WITH A MINIMUM DISTANCE BETVJEEN UNITS. J. CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETV DEVICES AS REQUIRED BV STATE AND LOCAL BUILDING CODES. K. ELECTRICAL CONTRACTOR TO VERIFV WORKING CONDITION OF ALL SWITCHES, LIGHT FI%TURES, BALLASTS, EXIT, AND EMERGENCV LIGHTS AND OUTLETS. REPLACE IF NECESSARV. L. DO NOT SCALE DRAWINGS; ALL DIMENSIONS GNEN ARE TO BE A�HERE� TO, UNLE55 RELD CONDITIONS DEEM OTHERWISE. ANV CONFLICTS THAT MAV EXIST WITH NEW CONSTRUCTION MIISTBEREVIEWEDBVDESIGNERPRIORTOCONSTRUCTIONOFWORK. DONOTCIRCUMVENT DIMENSIONS BV ATTACH W G RECEPTACLES TO NEAREST STl1D. M. ELECTRICAL/DATA OUTLET LOCATIONS TO BE VERIRED W ITH TENANT PRIOR TO ROUGH-IN. ALL LOCATIONS TO BE VERIFlED WITH FURNITURE PLACEMENT. N. ELECTRICALCONTRACTORISRESPONSIBLEFORCONNECTING�EALERPROVIDEDFURNITURE SVSTEMS POWER IN-FEED TO BWLDING bBOX WHERE INDICATED ON PLAN. O. TVSANDMOUNTINGEQUIPMENTNOTTOEXCEED4"FROMWALL. P. OUTLETS IN RATED PARTITIONS TO BE BACKED WITH SIB" TVPE X GWB OR USE PUTTY PACKS. � ELECTRICAL/DATA KEYNOTES 1. PLASTERRINGWITH(1)3l4"CONDUITANDPULLSTRINGTOACCESSIBLECEILINGFORTENANT SUPPLIED AND INSTALLED CARD REA�ER. MOUNT PLASTER RING CENTERLINE TO MATCH EXISTING COORDINATEALL WORK WITH TENANT'S IT VENDOR. 2. MODIFV EXISTING ELECTRICAL AND ROUGH-IN AS RE�UIRED FOR VOICEIDATA FEEDS ABOVE RNISHED CEILING FOR CONNECTION TO RELOCATED OR NEW POWER POLE(S) SERVING RELOCATED FURNITURE WORKSTATIONS. TERMINATE ELECTRICAL FEEDS IN J-BOX ABOVE CEILINGANDMAKEFINALCONNECTIONSTOPOWERPOLEASREpUIRED. COORDINATEALL WORK WITH TENANT. 3. MODIFV EXISTING OUTLET OR ADD ADDITIONAL OUTLETS SERVING THIS PRIMER AS REQUIRED TO ACCOMMODATE THE FOLLOW ING POW ER RE�UIREMENTS: 208 - 240V, 50/60HZ ON DEDICATED QRCUIT. COORDINATE ALL WORK DIRECTLV WITH TENANT. 4. MODIFVEXISTINGOUTLETORAD�AD�ITIONALOUTLETSSERVINGTHISPRINTERASREQUIRED TO ACCOMMODATE THE FOLLOW ING POW ER RE�UIREMENTS 208 - 2AOV, 16A, 50/60HZ ON ❑EDICATED CIRCUIT. COORDINATE ALL WORK DIRECTLV WITH TENANT. S MODIFVEXISTINGOURETORADDADDITIONALOURETSSERVINGTHISPRINTERASREQUIRED TO ACCOMMODATE THE FOLLOW ING POW ER REpUIREMENTS: 208 - 240V, i6A, SOI60HZ X 2 POWER CORDS ON DEOICATED CIRCUIT. COORDINATE ALL WORK DIRECTLV W ITH TENANT. 6. MODIFV EXISTING OUTLET OR ADD ADDITIONAL OUTLETS SERVING THIS PRINTER AS REQUIRED TO ACCOMMODATE THE FOLLOW ING POW ER RE�UIREMENTS: 100 - 240V W/60 HZ W ITH LESS THAN 1A CURRENT ON DEDICATED QRCUIT. COORDINATE ALL WORK DIRECTLV W ITH TENANT. ]. MODIFVEXISTINGOUTLETORADOADOITIONALOUTLETSSERVINGTHISPRINTERASREQUIRED TOACCOMMODATETHEFOLLOWINGPOWERREpUIREMENTS220VSINGLEPHASE 50/60HZAC 2HP ON DEDICATED CIRCUIT. COORDINATE ALL WORK DIRECTLV WITH TENANT. 8. MO�IFVEXISTINGOURETORADDADDITIONALOURETSSERVINGTHISPRINTERASREQUIRED TO ACCOMMODATE THE FOLLOWING POWER REQUIREMENTS: 120V 5�/60HZ ON DEDICATEO CIRCUIT. COOR�INATEALLWORKDIRECTLVWITHTENANT. 9. FURNISH AND INSTALL WALL MOUNTED ELECTRICALAND/OR DATAIVOICE FURNITURE BASE FEEDS A SHOWN. COORDINATE ALL WORK WITH TENANT. 10. INDICATES RELOCATED POWER AND COMMUNICATION DEVICES, TV, WALL MOUNTED BRACKET AND ALL ASSOQATE� PARTS FROM DEMOLITION PHASE. COORDINATE ALL WORK WITH TENANT. 11. FURNISHANDINSTALLNEW]5KVATRANSFORMER. 12. FURNISH AND INSTALL NEW 200 AMP ELECTRICAL PANEL. 13. INDICATES EXISTING 120/208 PANEL, 14. INDICATES EXISTING 120/208 400 AMP PANEL. 15. FURNISH AND INSTALL (2) 20KVA UPSs 2�8, BOAMP IN THIS ROOM. CONFIRM EXACT LOCATION WITH TENANT. 16. Fl1RNISHANDINSTALLNEW680VOLT,150AMPDISCONNECT. L MITSCH D E 5 I G N 200 5. Rangeline Rtl. I Suite 226 Carmel, Intliana 46W2 317.5732222 www.m itschdesign. com r1 W I� '1 11 a W � O � C!� 2 W w W J�MU � � J � i Q Q r I�I O O J Q m O � � J Z �, � Z O J W �Q Vz�Q r a' N w t� Q � U� Q r U U, p° V ` ............. "',f-- � ;. ��srEq , T= '�• �: eE N0. f�•': Z * ' ������ ' * � SiFiE Of _ ••�•.�iNp::N�.:�• �\� '���CH � T�E��111\\\ \ 000 Y ¢ w� u' <rwi�w �� m o z v� OZy ��H z— d Q w w U a � o � x � rc w �oo aan puiIJ�CPi �FORE�PES � : O m�sa�oEsoti.nuAOHrsRespveo.ece roRuae ELECTRICALIDATA PLAN IA251