HomeMy WebLinkAboutCarmel South Parking Garage Trash Room - E001GENERALNOTES (APPLY TO ALL ELECTRICAL SHEETS) i. aRovioEsuaaoaTwiRESFoanuucHrFixruREs. 2. COOR�INATEINSTALLATIONOFLIGHTFlXTURESWITHARCHITECTURALRERECTE�CBLINGPLAN,HVACEQUIPMENT, �l1CTWORK, PIPING AN� SOPPORTS. 3 ELECTRICALCONTRACTORSHALLVERIFVTHEEXISTINGCON�ITIONSATTHEPROJECTSITEBEFORESUBMITTINGCOST PROPOSAL. 4. ELECTRICALCONTRACTORSHALLREFERTOARCHITECTURAL�RAWINGSTOFAMILIARIZEHIMSELFWITHEXTENTOFREMO�ELING / ALTERATION WORK. 5. ALLWORKSHALLCONPoRMTOOREXCEEDTHEMINIMUMRE�UIREMENTSOFTHECURRENTANSIINFPAIOWITHSTATE AMENDMENTS, ENERGY CODE. AN51 I IEEE C2 AND ALL FE�ERAL, STATE, LOCAL AND MUNICIPAL CODES AND ORDINANCES. THE ELECTRICAL SUBCONTRACTOR SHALL WMPLV WITH THE DIRECTIONS OF ALL AUTHORITIES HAVING JURIS�ICTION. 6. INSTALL WORK USING PROCEDURES DEFINES IN NECA STANDARDS OF INSTALLATION. ALL WORK SHALL PRESENT A NEAT MECHANICAL APPEARANCE WHEN COMPLETED. ]. REFERTOTHEARCHITECTURALDRAWINGSFORCEILINGWORNBYTHEGENERALCONTRACTOR.COOR�INATEALLELECTRICAL WORK. 8. THEELECTRICALSUBCONTRACTORSHALLPROVIDEALLFLOOR,WALL,AN�CEILINGPENETRATIONSTOCOMPLETEHISIHER WORK.PROVI�EPROPERFIRESAFEINGFORALLPENETRATIONSMA�E. PROVI�EAPPROPRIATESEALANTQ.E.FIRESAFEING�TO MAINTAIN CONSTRUCTION INTEGRITY FOR ANV PENETRATIONS THROUGH FLOORS, STRUCTURAL CEILING, AND FIRE WALLS. 9. COORDINATEALLELECTRICALWORKWITHALLOTHERTRADESTOENSUREEFFECTIVEANDEFFIQENTOVERALLINSTALLATION. 10. COORDINATEALLELECTRICALSYSTEM�OWNTIMEWITHTHEOWNERAN�OTHERTRA�ES.ITISMAN�ATORYTHATTHEEXISTING BVIL�ING REMAIN M CONTINUOUS AND NON-IMERRUPTED OPERATION DURING THE REMODELING I ALTERING OF THE EXISTING 801L�ING. THE SPECIFIC AREA(5) BEING REMODELED I ALTERE� AT ANV TIME ARE OBVIOUSLV EXCLUSIVE OF THE STATEMENT. SERVICES TO EXISTWG BUILOING SHALL BE KEPT ON CONTINUOUS OPERATION INCLU�ING POWER, RRE ALARM, LIGHTING. TELEPHONE ETC. oObvNTIME OF THESE SVSTEMS SHALL BE MINIMIZED. WEEKEND AND AFTER HOURS WORK MAV BE RE�UIRED TO PREVENT OR M111NIA9ZE IMERFERENCE WITH OWNERS OPERATION. 11. CONTRACTORSHALLbVORKCLOSELVWITHTHEOWNERT0I�ENTIFVALL5V5TEM5WIRING,�EVICES,ETC.THATMUSTREMAIN OPERATIONAL oURING CONSTRUCTION. COORDINATE ALL DEMOLITION WITH THE OWNER PRIOR TO ANY DEMOLITION WORK. 12. THELOCATIONOFNEINRECEPTACLES,PHONE/�ATAJACKS,ANDROOMEpUIPMENTSHOWNONTHESEDRAWINGSARE APPROXIMATE RNAL LOCATIONS WILL BE �ETERMMED WITH THE ARCHITECT �URING THE CONSTRUCTION PHASE. 13. IN REMO�ELED i ALTERED AREA ANY FEEDERS, CONDUITS, BRANCH CIRCUITS, SIGNAL AND TELEPHONE qRCUITS, ETG PASSING THROl1GHOlIT THE REMODELED! ALTERE� AREAS TO SERVE (OR 8E SERVED FROM E%ISTING ADJACENT, REMOTE, OR SURROON�ING THAT ARE TO REMAIN� SHALL BE RETAINE� AN� KEPT OPERATIONS AN� SHALL BE REROUTED IN ALL CASES WHERE THEV INTERFERE WITH ANV NEW WORK OR USAGE TO BE ACCOMPLISHED IN THE REMODELED / ALTERE� AREA. 14. WHERE�EVICESAREOMITTE�FROMPRESENTBRANCHCIRCUITS,THEREMAINING�EVICESHALLBEREWIRE�.IFNEEDE�AN� AS REpUIRE�, TO REMAIN IN THEIR RESPECTIVE CIRCUITSAN� IN OPERATING CON�ITION. 15 ALLNEWEQUIPMENTSHALLBESUBMITfE�FORAPPROVALPRI0RT00R�ERING. i6. PHVSICALSIZESAN�LOCATIONSOFALLMECHANICALEpUIPMENTSHOWNONTHESE�RAWINGSAREAPPROXIMATE. COOR�INATE ELECTRICAL WORK FOR THIS EQUIPMENT WITH THE OTHER TRADES. 17. ALLBRANCHqRWITSSHALLUTILIZESEPARATEINDEPENDENTNEUTRALCONDUCTORS.DONOTCOMBINENEUTRAL coNoucroRs. 18. ALLFEE�ERNEUTRALIGROUN�E�CON�UCTORSSHALLBECONSI�ERE�CURRENTCARRVING.DERATEMULTIPLECONDUCTORS IN A RACEWAY ACCOROINGLV WITH NEC TABLES. 19. INSTALL ALL CONDUITS, RACEWAVS, AND CABLE TRAY FOR MAXIMUM HEAD CLEARANCE IN MECHANICAL AREAS. 20. ALL�EVICESSHOWNONTHESE�RAWINGSTOBEREMOVE�SHALLBEREMOVE�COMPLETEINCLU�INGALLASSOQATE� CON�UIT AND WIRING BACK TO SOURCE UNLESS OTHERWISE NOTED. ALL CIRW IT BREAKERS OR E�UIPMENT MADE SPARE BV THE �EMOLRION SHALL BE TURNE� OFF AND MARKED SPARE. IT IS THE INTENT THAT ALL EXISTING ELECTRICAL DEVICES, CON�UIT. WIRING, ETC. IN THIS SPACE THAT ARE NOT REUSE� AN� ARE ABANDONE� SHALL BE REMOVE� COMPLETE. CONTRACTOR SHALL FlELD VERIFV EXACT RE�UIREMENTS. NOTALL DEVICES ARE SHOWN ON THIS DRAWING. 21. ALL�EVICESANDLIGHTFIXTURESSHOWNTOBEREMOVE�FROMEXISTINGBLOCKWALLSTHATARENOTREUSE�SHALLHAVE BLANKCOVERSINSTALLE�. 22. ALLDEVICESSHOWNTOBEREMOVEDFROMEXISTINGWALLSTHATREMAINSHALLHAVEDEVICESAN�ASSOCIATEDCONDUIT REMOVED AND WALL SHALL BE PATCHED. 23. REFERTOMECHANICAL�EMOLITIONPLANSFORALLEpUIPMENTTHATISTOBEREMOVE�.REMOVEALLAS50QATE�CON�UIT AND WIRING TO THESE DEVICES. 24. ALLLIGHTFI%TURESSHOWNWITHEMERGENCYBATTERVBALLASTSSHALLHAVEUNSWITCHED"HOT'WIREINSTALLEDTO BALLAST. 25 NEWDEVICESSHOWNTOBEWSTALLEDONEkISTINGORVWALLWALLSSHALLBEINSTALLEDFWSHINWALLWITHCONDUITAND WIRING CONCEALED. CUT AND PATCH EXISTING WALLS AS REQUIRE�. 26. NEW DEVICES SHOWN TO BE WSTALLE� ON EXISTING BLOCK WALLS SHALL BE INSTALLE� SURFACE MOUNTED AN� IN SURFACE MOUNTE� WIREMOLD PAINTED TO MATCH WALL. 2]. WIRINGSHALLBEINSTALLE�ABOVEACCESSIBLECEILINGSAN�IN�RYINALLWALLSWHEREPOSSBLE. 28. NEW�EVICESSHALLMATCHEXISTINGDEVICESAN�COVERPLATES. 29. WHEREOCWPANCYSENSORSAREINDICATEOONPLANS.THEENTIREROOMSHALLBECOVERED.MANUFACTURERIS RESPONSIBLEFORSENSORLAVOUT. A��ITIONALSENSORSREpl11REDDUETOLACKOFCOVERAGESHALLBETHE RESPONSIBILITVOFTHEELECTRICALCONTRACTOR. PROVI�EOUANTITYASREpUIRE�. CEILINGAN�WALLMOUNTE�SENSORS SHALLeEOUALTECHNOLOGYTVPE. SENSORSSHALLINCLUDEALLPOWERSUPPLIESANDRELAVSNECESSARYTOCONTROL LIGHT FIXNRES IN ROOM I AREA. SENSORS SHALL OPERATE IN "VACANCV" MO�E � MANUAL ON / AUTO OFF. TYPE OC SpUARE - IN�ICATES A WALL MOUNTE� SINGLE CIRCUIT SENSOR WITH 1 SWITCH. TYPE ROUN� OC IN�ICATES A CEILING MOUNTED SENSOR. PROVIDE A SET OF AUXILIARV CONTACTS ON ALL WALL AND CEILING MOUNTED OCCUPANCY SENSORS PoR SENSOR STATUS PoR TEMPERATURECONTROL. 34 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN �EMOLITION, REMOVAL. CAPPING. STORING. ABANDONING, DISCONNECTION, RELOCATING AND RECONNECTION OF EXISTING ELECTRICAL EQUIPMENT AND MATERIAL. ALL CUTTING, PATCHING, REPAIRING, REPLACEMENT AND REFINISHING, SHALL MATCH THE E%ISTING CONSTRUCTION AS NEARLY AS POSSIBLE. 31. ALL WIRING (POWER, LIGHTING) NOT REUSE� FOR REMO�ELING AREAS SHALL BE COMPLETELV REMOVE� BACK TO ASSOCIATE� PANELS. 32. THEOWNERSHALLHAVETHEFIRSTCHOICETOACCEPTEXISTINGDEVICESBEINGREMOVED. 33. REMOVEALLABANDONE�CON�UITS,BOXESANDWIRINGWITHINPROJECTAREA. 34 FlRE ALARM SYSTEM SHALL BE MAINTAWED DURING PROJECT. 35. CEILING MOUNTE� �EVICES TO REMAIN SHALL BE SUPPORTE� FROM STRUCTURE �URING CONSTRUCTION AN� REINSTALLED IN NEW CEILING. 36. ARRANGEMENTS SHALL BE MADE WITH OWNER REPRESENTATNE TO COORDINATE FlRE ALARM SYSTEM OUTAGE. 3]. CONTRACTORSHALLPROTECTEXISTINGCABLESDURINGALLPHASESOFCONSTRUCTION. 38. ALLDEVICES�EXITSIGN$RREALARM.LIGHTINQETC�THATARETAKENOUTOFSERVICEAN�NOTREUSEDSHALLBERETURNE� TO THE OWNER. 39. ALLRECEPTACLESSHALLBEHOSPITALGRADEAN�SAFETV/TAMPERPROOFTVPE. SYMBOL � � � � � � � � � m m � 0 0 � m � 4Q� 4 � 1 � �P � oo-a o� � 0 � LIGHTING DESCRIPTION NO SHA�ING IN�ICATES NORMAL POWER HALF SHADED INDICATES LIFE SAFETV POWER FULL SHA�E� INDICATES EMERGENCV POWER 24' x 48" LIGHTING FIXTURE 24' x 24" LIGHTING FIXTURE 1Y x 40" LIGHTING FI%TURE 1Y x 36" LIGHTING FIXTURE 1Y x 24" LIGHTING FIXTURE 1Y x 12" LIGHTING FIXTURE 12' x 96" LIGHTING FIMURE fi" x 96" LIGHTING FIXTURE 6" x 48" LIGHTING FIXTORE fi" x 36" LIGHTING FIXTURE 6" x 24" LIGHTING FlXTURE 0" �OWNLIGHT 6"DOWNLIGHT 4" DOWNLI6HT WALL MOUNTED LIGHT CEILING EXIT LIGHT (DUAL FACE�) CEILING EXIT LIGHT (SINGLE FACE) WALL EXIT LIGHT WALL EXIT WITH EMERGENCY LI6HTS WALL EXIT WITH INTERIOR AN� EXTERIOR EMERGENCY LIGHTS EXIT LIGHT �IRECTIONAL ARROWS WALLEMERGENCYBATTERVLIGHT CEILMG EMERGENCY BATTERV LIGHT EXTERIOR POLE LIGHT (ONE HEAD) EXTERIOR POLE LI6HT (iW0 HEADS) EXTERIOR POLE LIGHT (THREE HEADS) EXTERIOR POLE LIGHT (FOUR HEADS) EXTERIOR POLE LIGHT (TOP MOUNT) EXTERIOR BOLLARD SYMBOL DESCRIPTION � Dl1PLEXRECEPTACLE�NORMALPOWERCIRCUIT A DUPLEXRECEPTAGLE-EMERGENCVPOWERCIRCUIT �p �UPLEXGFqRECEPTACLE-NORMALPOWERqRCUIT TM DUPLEXGFQRECEPTACLE-EMERGENCVPOWERCIRCUIT � pUADRAPLEXRECEPTACLE-NORMALPOWERCIRCUIT � pUADRAPLEHRECEPTACLE-EMERGENCYPOWERQRCUIT � �UADRAPLEXGFCIRECEPTACLE�NORMALPOWERCIRCUIT �!It pUADRAPLEXGFCIRECEPTACLE-EMERGENCYPOWERQRC y� SIMPLEXRECEPTACLE-NORMALPOWERCIRCUIT SIMPLEX RECEPTAQE - EMERGENCV POWER CIRCUIT � SPECIALRECEPTACLE�NORMALPOWERCIRCWT �m SPECIALRECEPTA0.E�EMERGENCYPOWERqRCUIT g DUPLEXRECEPTACLE-TOPSWITCHED RECEPTACLE LEGEND � RECEPTACLEABOVECOUNTERTOPATtYpgOVE BACKSPLASH TO BOTTOM OF DEVICE. COORDINATE WITH CASEWORK TO BE INSTALLE�. � RECEPTAQEINSTALLE�BELOWCOUNTERTOPATa18' rtI� A.F.F. WORDINATE WITH CASEWORK TO BE INSTALLED. ttX "%"DENOTESASFOLLOWS: NONE-20AMP.125VAC HM-20AMP,125VAC.HORIZONTALMOUNTTYPE IG - 20 AMP, 125VAC, ISOLATED GROVND TVPE S- 20 AMP,125VAC, SURGE GUARD PROTECTION TYPE ST � 20 AMP, 125VAC, SAFETY TYPE WP-20AMP.125VAC,WEATHERPROOFTVPE CEILING DUPLEX RECEPTA0.E-NORMAL POWER CIRCUIT CEILING DUPLEX RECEPTACLE-EMERGENCV POWER CIRCUIT CEILING QUA�RAPLEX RECEPTACLE - NORMAL POWER CIRCUIT CEILING QUADRAPLEX RECEPTAQE - EMERGENCV POWER CIRCUIT � FLOORBOX�UPLEXRECEPTAQE-NORMALPOWERQRCUIT � FLOORBOXDUPLEXRECEPTACLE-EMERGENCVPOWERCIRWIT � FLOORBOXQUA�RAPLEXRECEPTAQE-NORMALPOWERCIRCUIT � FLOORBOXQUA�RAPLEX RECEPTACLE-EMERGENCVPOWERCIRf � FLOORBOXBLANK � FLOORBOXPOWERAN�TELECOM W�A�W MULTI-OUTLETASSEMBLV�POWERAND/ORTELECOM) ELECTRICAL SPECIFICATIONS (APPLY TO ALL ELECTRICAL SHEETS) 26 05 00 - BASIC MATERIALS AND METHODS: 1. UTILITIES: 1.1. CONTRACTORTOCOORDINATEPOWER,TELEPHONE,ANDTELEVISION(CABLE�SERVICERE�UIREMENTSWITHLOCAL UTILITIES PRIOR TO SUBMIITING BID PROPOSAL. 2. SHOPDRAWWGS�. 21. SUBMITSHOP�RAWINGSTOINCLUDEMANUFACTURERCURRENTSPECIFICATIONAN�LITERATURE,HIGHLIGHTEDWITH OPTIONS PROVIDED AS PART OF THIS PROJECT. PROVIDED SHOP �RAWINGS FOR WIRWG DEVICES, CIRCUIT BREAKERS, LIGHTS, ELECTRONIC DRIVERS. PANEL BOARDS. AND FIRE AU+RM. 3. ALLELECTRICALCONNECTORSLUGS,BREAKERS,EpUIPMENT,ETC.,SHALLBERATE�AMINIMUMOF]S�EGREESC. 26 0519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES: 1. ALLBRANCHCIRCUITWIRINGSHALLBECONCEALE�INCONDUIT. 2. SINGLECON�UCTORSSHALLBEiVPETHHN,THWN,ORTHHNITHWN. 3. MINIMUMCONDUCTORSIZESHALLBEI2AWGPoR2�AMPERECIRCUITS. 4. ALLBRANCHCIRCUITSSHALLHAVE�E�ICATEDNEUTRALSCONDUCTORSPERCIRCUIT.SHAREDNEUTRALCONDUCTORSWILL NOTBEALLOWE�. 5. ALLFEE�ERAN�BRANCHQRCUITSSHALLINCW�EGROUN�INGCON�UCTORS. 26OS 26- GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS: 1. PROVI�ESEPARATEINSULATE�GREENGROUNDWIREWITHEACHBRANCHCIRWITASTHEEQUIPMENTGROUNDINGMEANS FOR ALL ELECTRICAL �EVICES AND EQVIPMENT. 26 OS 33 - RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS: 1. ALLIN�OORCON�OITSHALLBEELECTRICALMETALLICTOBING(EMT�ANDSHALLBEAMINIMUM3/4"UNLESSOTHERWISE NOiE�. UTILIZE COMPRESSION iVPE FITTINGS. USE FOR Ep01PMENT CONNECTION, FEE�ERS AN� BRANCH QRCUIT WIRING. ALL CONDOR WSTALLED ABOVE GRADE OUTSIDE OF THE BOIL�ING SHALL BE RIGID STEEL ALL CON�UIT INSTALLE� UNDERGROUNDSHALLBE SCHEDULEAOPVCUNLESSOTHERWISENOTED. NOPVCCONDUITSHALLBEUSEDABOVETHE FLOOR SLAB OR EXPOSED OUTSIDE THE BUILDING. 2. BOXESFORMETALLICRACEWAYSTOBEGALVANRE�STEEL.MINIMUMOF4"SpUARE,MINIMUMOF2-0/8"�EEP. 260553- IDENTIFICATION FOR ELECTRICAL SYSTEMS: 1. PROVIDENAMEPANELAN�CIRCUITLABELFORALLLIGHTINGCONTROLAN�RECEPTA0.ECOVERPLATES.LABELSFOR DEVICE COVER PLATES SHALL BE PRWiED, CLFAR LABEL WITH BLACN FONT. 2. ALLJUNCTIONBOXWVERSSHALLBELABELE�WIiHPANELANDCIRCUITI�ENTIRCATION. 26 09 23 - LIGHTING CONTROL DEVICES: 1. OCCUPANCYAN�VACANCVSENSORS: 1.1 CEILINGMOUNTED,SOLID-STATEOCCUPANCVSENSORS. 12 �UALTECHNOLOGV. 13. LISTEDAN�LABELEDAS�EFINEDINNFPAIO,BYpUALIFIE�TESTWGAGENCY,AN�MARKE�FORINTENDEDAPPLICATION IN �AMP LOCATIONS. 26 27 26 - WIRING DEVICES: 1. RECEMA0.ES: 1 1. NEMA &20R, �UPLEX,125V,GROUNDING TVPE, COMMERCIAL OR SPEQFICATION GRADE, WHITE COLOR. AS MANUFACTURE� BY EATON, HUBBELL, LEVRON.OR PASS 85EVMOUR. MOONT AT 18" A.F F. TO CENTER UNLE55 OTHERWISE NOTED. 2. GFCINPERECEPTACLES'. 1.1. NEMAi20GFlDUPLEX,125V,5MILLIAMPSENSITIVITYTRIPSELFTESTING,TAMPER�RE5ISTANT,GROUN�INGNPE. COMMERqALGRADE.WHITECOLOR. LEVITON1899-WORE�UALASMANUFACTUREDBVEATON,HUBBELL,ORPASSB SEYMOUR. MOUNTATIB"A.F.F.TOCENTERUNLESSOTHERWISENOTE�. 3. TOGGLESWITCHES: 1 1. 20 AMP, 120 VAC RATED, pUIET TVPE, SPEQFICATION GRADE. SPST, 3�WAV, OR A-WAV TVPE AS IN�ICATED ON THE DRAWINGS. HUBBELL 1221-I OR EQUAL AS MANUFACTURE� 8Y EATON, LEVITON, OR PASS 8 SEVMOUR. 4. FACEPLATES/COVERPLATES'. WEATHERPROOFPLATESSHALLBECASTALUMINUMGASKETE�,RAINTIGHTWMLE-IN-USETVPE. 26 51 00 - INTERIOR LIGHTING: RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel ` � �un��V l�rcNal�=L. \ DATE: 03�03�20 L LIGHTING: 1.1. FIXTURESANDACCESSORIESSHALLBELLLLISTE�AN�LABELE�. 12. OUT�OOR FIXTURE SHALL INCLU�E WFATHERPROOF HOUSING, WETI�AMP LABEL, AN� 20°F COL� TEMPERATURE RATED BALLASTS OR �RNERS. SYMBOL DESCRIPTION OM MANUALSENDINGSTATION S� WALLSMOKEDETECTOR SD WALLSMOKEDETECTORWITHSOUN�ERBASE S� CEILING SMOKE �ETECTOR 5� CEILING SMOKE DETECTOR WITH SOUNDER BASE � AUTOMATICDUCTDETECTOR�"X"DENOTESASPoLLOWS) % NONE -PHOTOELECTRICTVPE S-SUPPLV R RETURN RT REMOTE�ETECTORTESTSTATION RI REMOTE �ETECTOR IN�ICATOR STATION � HEATDETECTOR F� FLAME �ETECTOR BD BEAM DETECTOR OH WALLHORNONLY � WALLHORNSTROBE OH CEILING HORN ONLV �H CBLING HORN STROBE OS WALLSPEAKERONLV � WALLSPEAKERSTROBE �5 CBLINGSPEAKERSTROBE � WALLVISUALONLV �V CEILINGVISUALONLY � FIREALARMAD�RESSABLERELAY JO FlREMANSJACK �U DOOR UNLOCK D� �OORRELEASE FS SPRINKLER SVSTEM FLOW SWITCH OS SPRINKLERSVSTEMTAMPERSWITCH I� POSTINDICATORVALVE FACP FlREALARMCONTROLPANEL FAAP FIREALARMANNUNCIATORPANEL NAC FlREALARMNOTIFICATIONAPPLIANCECOMROLPANEL SYMBOL DESCRIPTION � PA�MOUNTE�TRANSFORMER � SUSPENDE�TRANSFORMER � �ISTRIBUTION PANELBOARD � BRANCHPANELBOAR�-RECESSE�MOUNT � BRANCHPANELBOAR�-SURFACEMOUNT o� oiscoNNEcrswircn-non-FusEo B' DISCONNECT SWITCH � FUSED � MOTORCONTROLLER �' COMBINATIONMOTORCONTROLLERI�ISCONNECT �o TELECOMTERMINALBOAR� �= GROUN� BAR � JUNCTIONORPULLBO% N PUSHBOTTON OR PUSH PLATE � ELECTRICTHERMOSTAT rC*�Y MOTOR�"X"�ENOTESHORSEPOWERJ - - MOL�EDCASEqRCUITBREAKER � GROON� CONNECTION • GROON� POINT � GROUN�RO� � cENERnTOR � AUTOMATICTRANSFERSWITCH ELECTRICAL SWITCHES SYMBOL DESCRIPTION �j TOGGLESWITCH�20AMP,120/277VAC g'j3 TOGGLESWITCH-3WAV �j� TOGGLESWITCH-4WAV g'jK TOGGLESWITCH-KEYOPERATED $T TOGGLESWITCH-HORSEPOWERRATEDMANUALMOTOR STARTER WITH THERMAL OVERLOAD PROTECTION �'jP TOGGLESWITCH�PILOTLIGHT Q DIMMERSWITCH-20AMP,12012]]VAC �D 3 �IMMERSWITCH-3WAV �D 4 DIMMERSWITCH-4WAV oc WALLOCCUPANCYSENSOR�iBUTTONCONTROL ocz WALLOCCUPANCVSENSOR-2BUTTONCONTROL oca �'ALLOCCUPANCYSENSOR-0UALRELAVFOR EXHAUSTFANCONTROL � cEiuNcoccuanNcvsENsoR wi WALNACANCYSENSOR-1BUTTONCONTROL vsx WALLVACANCYSENSOR-2BUTTONCONTROL LC LOW VOLTAGE LIGHTING CONTROLLER �T 0-3HOURTIMERSWITCH�20AMP,12012]NAC PC PHOTOCELL ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION AorAMP AMPERE HZ HERTZ AC ALTERNATMG CURRENT IC INTERCOMMUNICATION AIC AIRCONDITIONMG ID WSIDE�IAMETER ACP ACCESSPANEL WCAN INCAN�ESCENT ACU AIRCONDITIONMGUNIT MCL INCWDE A�D ADDITION ISG ISOLATEDGROUNDSURGEGUARD ADJ ADJUSTABLE JB JUNCTION BOX AF AMPERE FRAME JT JOINT AFC ABOVEFINISHEDCEILING KEC KRCHENEpUIPMENTCONTRACTOR AFF ABOVEFINISHEDFLOOR KT KRCHENETTE AFG ABOVEFINISHEDGRA�E KVA KILOVOLTAMPERE AHU AIRHAN�LINGUNIT KVAR KILOVOLTAMPEREREACTIVE AIC AMPEREINTERRUPTMGCAPACITY KW KILOWATT AL ALUMINUM LAB LABORATORV AM AMMETER L8 POUN� AMB AMBIEM LF LINEAR FEET APPROX. APPRO%IMATELV LOC LOCATION ARCH ARCHITECT LS LIFESAFETV ATS AUTOMATICTRANSFERSWITCH LT LIGHT AUTO AUTOMATIC LTG LIGHTING AVG AVERGE LV LOWVOLTAGE BC BARECOPPER MATV MASTERANTENNATELEVISION BKR BRFAKER MA% MAXIMUM BHP BRAKEHORSEPOWER MC MECHANICALCONTRACTOR BL BUIL�INGLINE MCB MAINCIRCUITBREAKER BLDG BWLDING MCC MOTORCONTROLCENTER BR BRANCH MDP MAIN DISTRIBUTION PANEL BTM BOTTOM MECH MECHANICAL C CON�UIT MH MANHOLE °C DEGREESCELSIUS MIN MINIMUM CAB CABINET MISC MISCELLANEOUS CBorCB CIRCUITBREAKER MLO MAWWGSONLV C/C CENTERTOCENTER MT� MOUNTED CCTV CLOSEDCIRCUITTELEVISION MTGHT MOUNTINGHEIGHT CKT CIRCUR MU MEDICINE UNR CL CENTERLINE 0� OUTSI�EDIAMETER CLG CEILING OFQ OWNERFURNISHE�-CONTRACTORINSTL COL COLUMN OF01 OWNERFURNISHED-OWNERINSTALLED COMM COMMUNICATION OPNG OPENING COMP COMPRESSOR OPP OPPOSRE CONC CONCRETE OR OPERATING ROOM CONST CONSTRUCTION P POLE CONT CONTINUOUS PB PUSHBUTTON CONTR CONTRACTOR PBOX PULLBOX CR CRITICAL PE PNEUMATICELECTRICCONVERTER CT CURRENTTRANSFORMER PF POWERFACTOR CU COPPER PHorO PHASE �B �IRECTBURIAL PV POSTIN�ICATORVALVE �C �IRECTCURRENT PNL PANELBOAR� DEPT DEPARTMENT PL PILOTLIGHT DF DRINKMGFOUNTAIN PREFAB PREFABRICATE� �IST �ISTRIBOTION PRES PRESSURE �M �EMAN�METER PT PNEUMATICTUBE DO DRAWOUT PTS PNEUMATICTUBESTATION DRS DOCTORS PW PARTWINDING �WG �RAWING PWR POWER EC ELECTRICALCONTRACTOR RACV ROOMAIRCONDITIONINGUNIT EF E%HAUSTFAN RA� RADIATION ELEC ELECTRIC RECEPT RECEPTACLE ELEV ELEVATOR REForREFR REFRIGERATOR ELV ELEVATION REINF REINFORCE� EMER EMERGENCY RGIP REMOTEGROUNDINDICATINGPANEL ENCL ENCLOSURE RM ROOM EP ELECTRICPNEUMATIC RPM REVOWTIONSPERMINOTE EpUIP EpUIPMENT SA SUPPLVAIR EWC ELECTRIC WATER COOLER SC SHORT CIRCUIT EX E%PLOSIONPROOF SG SURGEGUAR�PROTECTION EXH EXHAUST SHT SHEET EXP E%PANSION SIG SIGNAL EXT E%TERIOR SN SOLIDNEUTRAL °F DEGREES FAHRENHEIT SPEC SPECIFICATIONS FA FIREALARM SQ SpOARE FAAP FIREALARMANNONCIATORPANEL 55 SAFETYSWITCH FAW FIREALARMCONTROLPANEL 5555 SOLIDSTATESOFTSTART FC FLAT CABLE ST� STAN�ARD FCU FANCOILUNIT STN STATION FFC FOODFACILITYCONTRACTOR STR STRUCTURAL FFS FOODFACILITYSUPPLIER SUSP SUSPEN�ED FHC FIREHOSECABINET SW SWITCH FIN FINISH SWB� SWITCHBOAR� FlXT FIXTURE SWGR SWITCHGEAR FL FLOOR TCC TEMPERATURECONTROLWNTRACTOR FLUOR FLUORESCENT TELE TELECOMMUNICATION FLEX-WNN FLEXIBLECONNECTION TEMP TEMPERATORE FPC FIREPROTECTIONCONTRACTOR TMH TOPOFMANHOLE FSS FUSE�SAFETYSWITCH TV TELENSION FTG FOOTING TVP TVPICAL FVR FlLMVIEWER UC UN�ERCARPET FV FULLVOLTAGE UIC UNDERCA81NETorUN�ERC011NTER FVNR FULLVOLTAGENONREVERSING UH UNITHEATER GorGND GROUN� UV UNITVENTILATOR cn�v cn�vnNizeo v vo�r GC GENERALCONTRACTOR VAC VACUUM GEN GENERATOR V8 VACUUM BREAKER GFQ GROUN�FAULTCKT.INTERRUPTER VC VACUUMCLEANING GFI GROON�FAULTINTERRUPTER VEL VELOCITV GFP GROON� FAIILT PROTECTION VF� VARIABLE FREpOENCY �RIVE HGT HEIGHT VM VOLTMETER HH HAN�HOLE VOL VOLUME HI� HIGHINTENSITY�ISCHARGE VP VAPORPROOF HO HAN� OPERATE� VSD/VFC VARIABLE SPEED DRIVE/CONTROLLER HOA HAN�-0FF�AUTOMATIC WI WITH HORZ HORIZONTAL W/0 WITHOUT HP HORSEPOWER WTR WATER HPS HIGHPRESSIIRESODIUM WP WEATHERPROOF HTR HEATER WT WEIGHT HV HIGHVOLTAGE %FMR TRANSFORMER Z IMPE�ANCE SYMBOL DESCRIPTION �FEE�ER SIZE. (REFER TO FEE�ER SCHEDULE FOR ADDITIONAL WPoRMATION FX�PHASECON�UCTORS NEUTRAL Y GROUND LIGHTISCREENE� SOLI� OR �ASHE� LINES INDICATE E%ISTING TO REMAIN --- HEAVV DASHED LWES IN�ICATE EXISTING TO BE REMOVE� HEAVV CONTINUOUS LMES IN�ICATE NEW WORK � �.i W � O � � - / � 2 � Z O � Ww _ / � W � � O Z I Q ` _ / Z O � � Q �` I W � � � a � Z Q - / O W ` - / J J Q 618 Easf Market Sireet Indionopolis, Indiono 46202 phone 31 ]/46d 8162 a x i s a r c h. c o m oaAwN ar a�mKeoer � r„� ��..-�sz���� �.,v�����9 aevisoNs DE34T�iv iOm iW}E Owner AMBROSEPROPERTVGROUP Eric Seamands, Dev. Manager 55 Monument Circle, Sui�e 450 Intlianapolis, Intliana 46204 31�.5]34600 Consfruction Manager: F.A. WILHELM CONSTRUCTION Doug Curts, VP Prolect Opera�ions 3914 Prospect Sireet Intlianapolis, Indiana 46203 317.359.5411 Givil Engineer: S}rucWml Engineer: in iono o�..irva62a0 �me.5ui�ea.4' 31�JAJ28EC0 MEP Eo9ineee.C11n roY �oo,� ,,, u�a a reeis�oe wo a�znn wm � � N � � ro � � � 3Q � O NZ W O Z Q a � Q� � y w Z � N W W � � lj O ~ �� � � � m U ` Q ; PE10708732 n �5 SiAIE OG ELECTRICAL SYMBOLS & GENERAL NOTES E001 aRo�Ecr Nuri,eEx: 1 9032