H1 PARTIAL THIRD FLOOR PLAN - NW
SCALE : 1/8" = 1' -0"
GENERAL NOTES (ENLARGED PLANS:
1. ALL DIMENSIONS ARE TO THE FACE OF DRYWALL UNLESS
NOTED OTHERWISE
2. REFER TO SHEETS A2.01 —A2.05 OVERALL FLOOR PLANS
FOR FOR MORE INFORMATION.
3. REFER TO A2.01 -2.24 FLOOR PLANS FOR WINDOW
LOCATIONS. REFER TO BUILDING ELEVATIONS FOR WINDOW
TYPES.
4. REFER TO DOOR SCHEDULE SHEET A8.01 AND DOOR
DETAILS SHEET A8.03; REFER TO WINDOW TYPES SHEET A8.04
AND WINDOW DETAILS SHEETS A8.05 -8.06 FOR MORE
INFORMATION.
5. REFER TO ROOM FINISH SCHEDULE ON SHEET A9.01 FOR
MORE INFORMATION.
6. VERIFY ROUGH FRAMING REQUIREMENTS FOR ALL BATH do
SHOWER UNITS.
7. ALL DOORS THIS SHEET TO BE 4" OFF ADJACENT WALL AT
HINGE JAMB AND 18" CLEAR FROM PERPENDICULAR WALL AT
STRIKE JAMB U.N.O. EXCEPT AT POCKET DOORS (SEE
DETAILS).
8. PROVIDE BLOCKING IN WALL AT ALL RESIDENT TOILETS FOR
FUTURE REAR GRAB BAR.
9. DRYWALL TO RUN CONTINUOUS BEHIND TUB AND /OR
SHOWER UNITS AT RATED WALLS.
10. SEE SHEET A8.06 FOR WALL CONSTRUCTION AT POCKET
KEYED NOTES (ENLARGED PLANS):
1❑ LEAN RAIL ® 2' -10" A.F.F. (REFER TO — /A6.06)
12 CONTINUOUS SLIDING ROD W/ 12" WIRE SHELF ABOVE
(CLOSETMAID OR EQUAL). INSTALL SHELF ® 5' -6" A.F.F.
TYPICAL (4' -6" A.F.F. IN A.DA COMPLIANT UNITS).
3❑ (5) 12" DEEP (24" DEEP AT ROOM IGG11) CLOSE MESH
WIRE SHELVES. (CLOSETMAID OR EQUAL). INSTALL EQUALLY
SPACED FROM 1' -6" A.F.F. TO 5' -6" A.F.F. TYPICAL
® SEMI — RECESSED, RATED FIRE EXTINGUISHER CABINET —
INSTALL TO AUGN BOTTOM OF CABINET W/ CORRIDOR LEAN
RAIL
❑
5 FIREPLACE —SEE SPECIFICATION.
OROOF BELOW —REFER TO ROOF PLAN ON SHEEP A2. FOR
ROOF NOTES AND DIMENSIONS.
7 CORRIDOR BULKHEAD/PILASTER —SEE 3/A5.08 do 4/A5.08.
HORIZONTAL RECESSED MAILBOXES BY SALISBURY INDUSTRIES.
�g WASHER AND DRYER UNIT W/ WALL UTILITY PACK AND
OVERFLOW PAN.
10 12" DEEP CLOSE MESH UTILITY SHELF.
NOTE: REFER TO SHEETS A4,01 THRU A4,43
FOR ENLARGED RESIDENT UNIT PLANS,
TYPICAL WALL TRIM LEGEND
HANDRAIL
SEE 4/A5,08
LEAN RAIL (CHAIR RAIL)
SEE 3/A5,08
N
KEY PLAN "e`
NOT TO scut s
1[[
Tennill and Associates
Design
177 Chesterfield Industrial
11111
Blvd.
Engineer
Chesterfield, MO 63005
Ph:(636) 537 -3999
Fax:(636) 537 -3996
ARCHITECTS
Austin
Carolinas
Denver
New York
St. Louis:
319 North 4th Street
Suite 1000
St. Louis, MO 63102
#Wv .i1f /2.i1 -57X
for J1411J1 -M76
Project Team:
General
Paric Corporation
Contractor
1001 Boardwalk Springs
Place
O'Fallon, MO 63366
Ph.(636) 561 -9500
Fax:(636) 561 -9501
Civil
The Schneider Corporation
Engineer
8901 Otis Avenue
Indianapolis, IN 46216
Ph:(317) 826 -7100
Fa9317) 825 -7200
Structural
Alper Audi, Inc.
Engineer
1804 Borman Circle Drive
St. Louis, MO 63146
Ph:(314) 432 -8600
Fax(314) 432 -8630
Mechanical Charles E. Jarrell Mechanical
Design Contractors
Engineer 4208 Rider Trail North
Earth City, MO 63045
Ph:(314) 291 -0100
Fmc(314) 291 -2803
Electrical Bell Electrical Contractors
Design 128 Millwell Drive
Engineer Maryland Heights, MO 63043
Ph:(314) 739 -7744
Fox:(314) 739 -0717
Plumbing
Tennill and Associates
Design
177 Chesterfield Industrial
Engineer
Blvd.
Engineer
Chesterfield, MO 63005
Ph:(636) 537 -3999
Fax:(636) 537 -3996
Fire
Fire Protection Systems
Protection
4316 Bridgeton Industrial
Design
Drive
Engineer
Bridgeton, MO 63044
Ph:(314) 739 -1400
Fox:(314) 739 -6401
Food Service Dennis G. Glore, Inc.
Designer: P.O. Box 200
Eureka, MO 63025
Ph:(636) 938 -7887
Ph:(636) 938 -6590
Professional Seal: ����'11 "118,14
O W L'% _ #I.
,,,�
The Professional Architect's seal affaced to this sheet apples only to
the material and hems shown on this sheet. All drawings.
instruments or other documents not odd b>6rg this seal shall not be
considered prepared by this archhect and this archHted expressly
declaims any and all nmpon lik for such plans, drawings or
documents not exhibiting this sed.
m
c
0
114=9
U
p7t
U v
in 0
w
0 g � �
�
� 2 Cd N
This drawing and details on it are the sole property
of the architect and may be used for this specific
project only. It shall not be loaned, copied or
reproduced, in whole or in part, or for any other
purpose or project without the written consent of the
architect.
No. Revision Description Date
Sheet Title:
PARTIAL
THIRD
FLOOR PLAN - NW
Project um er: Sheet Number:
05267
Drawn y:
KS, Al
Issue Date: A2M18
July 12, 2006
N
I
PARTIAL THIRD FLOOR PLAN - SW
SCALE : 1/8" = 1' -0"
GENERAL NOTES (ENLARGED PLANS):
1. ALL DIMENSIONS ARE TO THE FACE OF DRYWALL UNLESS
NOTED OTHERWISE.
2. REFER TO SHEETS A2.01 —A2.05 OVERALL FLOOR PLANS
FOR FOR MORE INFORMATION.
3. REFER TO A2.01 -2.24 FLOOR PLANS FOR WINDOW
LOCATIONS. REFER TO BUILDING ELEVATIONS FOR WINDOW
TYPES.
4. REFER TO DOOR SCHEDULE SHEET A8.01 AND DOOR
DETAILS SHEET A8.03; REFER TO WINDOW TYPES SHEET A8.04
AND WINDOW DETAILS SHEETS A8.05 -8.06 FOR MORE
INFORMATION.
5. REFER TO ROOM FINISH SCHEDULE ON SHEET A9.01 FOR
MORE INFORMATION.
6. VERIFY ROUGH FRAMING REQUIREMENTS FOR ALL BATH &
SHOWER UNITS.
7. ALL DOORS THIS SHEET TO BE 4" OFF ADJACENT WALL AT
HINGE JAMB AND 18" CLEAR FROM PERPENDICULAR WALL AT
STRIKE JAMB U.N.O. EXCEPT AT POCKET DOORS (SEE
DETAILS).
8. PROVIDE BLOCKING IN WALL AT ALL RESIDENT TOILETS FOR
FUTURE REAR GRAB BAR.
9. DRYWALL TO RUN CONTINUOUS BEHIND TUB AND /OR
SHOWER UNITS AT RATED WALLS.
10. SEE SHEET A8.06 FOR WALL CONSTRUCTION AT POCKET
KEYED NOTES (ENLARGED PLANS):
[fl LEAN RAIL ® 2'- 100A.F.F. (REFER TO — /A6.06)
Q2 CONTINUOUS SLIDING ROD W/ 12' WIRE SHELF ABOVE
(CLOSETMAID OR EQUAL). INSTALL SHELF ® 5' -6" A.F.F.
TYPICAL (4' -6" A.F.F. IN A.DA COMPLIANT UNITS).
31 (5) 12" DEEP (24' DEEP AT ROOM JGG11) CLOSE MESH
WIRE SHELVES. (CLOSETMAID OR EQUAL). INSTALL EQUALLY
SPACED FROM 1' -60 A.F.F. TO 5' -60 A.F.F. TYPICAL
® SEMI — RECESSED, RATED FIRE EXTINGUISHER CABINET —
INSTALL TO ALIGN BOTTOM OF CABINET W/ CORRIDOR LEAN
RAIL
❑5 FIREPLACE -SEE SPECIFICATION.
Efl ROOF BELOW - REFER TO ROOF PLAN ON SHEEP A2. FOR
ROOF NOTES AND DIMENSIONS.
❑7 CORRIDOR BULKHEAD /PIIASfER -SEE 3/A5.08 k 4/A5.08.
HORIZONTAL RECESSED MAILBOXES BY SALISBURY INDUSTRIES.
aWASHER AND DRYER UNIT W/ WALL UTILITY PACK AND
OVERFLOW PAN.
10 12" DEEP CLOSE MESH UTILITY SHELF.
NOTE: REFER TO SHEETS A4,01 THRU A4,43
FOR ENLARGED RESIDENT UNIT PLANS,
TYPICAL WALL TRIM LEGEND
HANDRAIL
SEE 4/A5,08
LEAN RAIL (CHAIR RAIL)
SEE 3/A5,08
N
KEY PLAN "(9`
NOT TO sceic s
1[[
Tennill and Associates
Design
177 Chesterfield Industrial
11111
Blvd.
Engineer
Chesterfield, MO 63005
Ph:(636) 537 -3999
Fam(636) 537 -3998
ARCHITECTS
Austin
Carolinas
Denver
New York
St. Louis:
319 North 4th Street
Suite 1000
St. Louis, MO 63102
phoi►ie .314101 -57W
far J1412..3l -M78
Project Team:
General
Paric Corporation
Contractor
1001 Boardwalk Springs
Place
U
O'Fallon, MO 63366
m
Ph:(638) 561 -9500
Fag838) 581 -9501
Civil
The Schneider Corporation
Engineer
8901 Otis Avenue
C
Indianapolis, IN 46216
0
Ph:(317) 826 -7100
Co
Fag317) 826 -7200
Structural
Alper Audi, Inc.
Engineer
1804 Borman Circle Drive
St. Louis, MO 63146
Ph:(314) 432 -8600
Fax:(314) 432 -8630
Mechanical Charles E. Jarrell Mechanical
Design Contractors
Engineer 4208 Rider Trail North
Earth City, MO 63045
Ph:(314) 291 -0100
Fax:(314) 291 -2803
Electrical Bell Electrical Contractors
Design 128 Millwell Drive
Engineer Maryland Heights, MO 63043
Ph:(314) 739 -7744
Fax{314) 739 -0717
Plumbing
Tennill and Associates
Design
177 Chesterfield Industrial
Engineer
Blvd.
Engineer
Chesterfield, MO 63005
Ph:(636) 537 -3999
Fam(636) 537 -3998
Fire
Fire Protection Systems
Protection
4316 Bridgeton Industrial
Design
Drive
Engineer
Bridgeton, MO 63044
Ph:(314) 739 -1400
Fax:(314) 739 -6401
Food Service Dennis G. Glore, Inc.
Designer: P.O. Box 200
Eureka, MO 63025
Ph:(638) 936 -7887
Ph:(636) 938 -6590
Professional Seal: ����'�� "�r�l•,,
.0 %.%
The Professional Architect's seal &&W to this sheet applies only to
the material and Rams d wn on this sheet. All drawings.
instruments or other documents not eahblU g this seal dml not be
considered prepared by this archhct. and this archibect a gnwdy
disdains any and al nniumliity for such plans. drawings or
docunnerft not exhibiting this sed.
c
m
c
O
C
(Uj U
971i
This drawing and details on it are the sole property
of the architect and may be used for this specific
project only. It shall not be loaned, copied or
reproduced, in whole or in part, or for any other
purpose or project without the written consent of the
architect.
No. Revision Description Date
Sheet Title:
PARTIAL
THIRD
FLOOR PLAN - SW
Project um er: Sheet Number:
05267
Drawn y:
KS, AI
Issue Date: A2019
July 12, 2006
0
co
U
v
m
a
W
!�
C
O
0
�
Co
(0
a
`2
N
This drawing and details on it are the sole property
of the architect and may be used for this specific
project only. It shall not be loaned, copied or
reproduced, in whole or in part, or for any other
purpose or project without the written consent of the
architect.
No. Revision Description Date
Sheet Title:
PARTIAL
THIRD
FLOOR PLAN - SW
Project um er: Sheet Number:
05267
Drawn y:
KS, AI
Issue Date: A2019
July 12, 2006
TH[111111
6fl01
ARCHITECTS
Austin
Tennill and Associates
Carolinas
177 Chesterfield Industrial
Denver
Blvd.
New York
Chesterfield, MO 63005
St. Louis:
319 North 4th Street
Suite 1000
St. Louis, MO 63102
31412 -71 -57W
fm J1411YI -WX
Project Team:
General Panic Corporation
Contractor 1001 Boardwalk Springs
Place
O'Fallon, MO 63366
Ph :(636) 561 -9500
Fax:(638) 561 -9501
Civil The Schneider Corporation
Engineer 8901 Otis Avenue
Indianapolis, IN 46216
Ph:(317) 826 -7100
Fagg) 826 -7200
Structural Alper Audi, Inc.
Engineer 1804 Borman Circle Drive
St. Louis, MO 63146
Ph:(314) 432 -8600
Fax:(314) 432 -8830
Mechanical Charles E. Jarrell Mechanical
Design Contractors
Engineer 4208 Rider Trail North
Earth City, MO 63045
Ph:(314) 291 -0100
Fax. {314) 291 -2803
Electrical Bell Electrical Contractors
Design 128 Millwell Drive
Engineer Maryland Heights, MO 63043
Ph:(314) 739 -7744
Fax:(314) 739 -0717
Plumbing
Tennill and Associates
Design
177 Chesterfield Industrial
Engineer
Blvd.
Engineer
Chesterfield, MO 63005
�
Ph:(636) 537 -3999
Fax:(638) 537 -3998
Fire
Fire Protection Systems
Protection
4316 Bridgeton Industrial
Design
Drive
Engineer
Bridgeton, MO 63044
�
Ph:(314) 739 -1400
Fox:(314) 739 -6401
Food Service Dennis G. Glore, Inc.
Designer: P.O. Box 200
Eureka, MO 63025
Ph:(636) 938 -7887
Ph:(636) 938590
Professional Seal:�� *�'�� "�r +l�,��
0 No. AR10.000256 W
r - •
•r •
STATE OF
40 9
•�
The Wasaiond Arc deals seal affixed to this sheet apples only to
the material and tterne shown on this sheet All drawings.
imbumenb or attw documents not exhibiting this seal steal not be
considered prepared by this archfiect, and this archited expressly
dndaims any and all responsibity for such plans. drawings or
docurnenb not exhibiting this sed.
iJ
11
co
a g IM
0
Cr.
� �` N
This drawing and details on it are the sole property
of the architect and may be used for this specific
project only. It shall not be loaned, copied or
reproduced, in whole or in part, or for any other
purpose or project without the written consent of the
architect.
No. Revision Description Date
Sheet Title:
PARTIAL
THIRD
FLOOR PLAN - SE
Project um er: Sheet Number:
05267
Drawn y:
KS, AI
ssue Date: —A2020
July 12, 2006
C
0
�
U
11
co
a g IM
0
Cr.
� �` N
This drawing and details on it are the sole property
of the architect and may be used for this specific
project only. It shall not be loaned, copied or
reproduced, in whole or in part, or for any other
purpose or project without the written consent of the
architect.
No. Revision Description Date
Sheet Title:
PARTIAL
THIRD
FLOOR PLAN - SE
Project um er: Sheet Number:
05267
Drawn y:
KS, AI
ssue Date: —A2020
July 12, 2006
52' -5 1/2"
13' -8 3/8"
32' -1 1/4"
'p�,1 PARTIAL THIRD FLOOR PLAN - NE
SCALE : 1/8" = V -0"
GENERAL NOTES (ENLARGED PLANS):
1. ALL DIMENSIONS ARE TO THE FACE OF DRYWALL UNLESS
NOTED OTHERWISE.
2. REFER TO SHEETS A2.01 —A2.05 OVERALL FLOOR PLANS
FOR FOR MORE INFORMATION.
3. REFER TO A2.01 -2.24 FLOOR PLANS FOR WINDOW
LOCATIONS. REFER TO BUILDING ELEVATIONS FOR WINDOW
TYPES.
4. REFER TO DOOR SCHEDULE SHEET A8.01 AND DOOR
DETAILS SHEET A8.03; REFER TO WINDOW TYPES SHEET A8.04
AND WINDOW DETAILS SHEETS A8.05 -8.06 FOR MORE
INFORMATION.
5. REFER TO ROOM FINISH SCHEDULE ON SHEET A9.01 FOR
MORE INFORMATION.
6. VERIFY ROUGH FRAMING REQUIREMENTS FOR ALL BATH &
SHOWER UNITS.
7. ALL DOORS THIS SHEET TO BE 4" OFF ADJACENT WALL AT
HINGE JAMB AND 18" CLEAR FROM PERPENDICULAR WALL AT
STRIKE JAMB U.N.O. EXCEPT AT POCKET DOORS (SEE
DETAILS).
8. PROVIDE BLOCKING IN WALL AT ALL RESIDENT TOILETS FOR
FUTURE REAR GRAB BAR.
9. DRYWALL TO RUN CONTINUOUS BEHIND TUB AND /OR
SHOWER UNITS AT RATED WALLS.
10. SEE SHEET A8.06 FOR WALL CONSTRUCTION AT POCKET
DOORS.
KEYED NOTES (ENLARGED PLANS):
[1] LEAN RAIL 0 2'- 107A.F.F. (REFER TO — /A6.06)
Efl CONTINUOUS SLIDING ROD W/ 12" WIRE SHELF ABOVE
(CLOSETMAID OR EQUAL). INSTALL SHELF 0 5' -6" A.F.F.
TYPICAL (4' -6" A.F.F. IN A.DA COMPLIANT UNITS).
30 (5) 12" DEEP (24' DEEP AT ROOM JGG11) CLOSE MESH
WIRE SHELVES. (CLOSETMAID OR EQUAL). INSTALL EQUALLY
SPACED FROM 1' -6" A.F.F. TO 5' -6" A.F.F. TYPICAL
® SEMI — RECESSED, RATED FIRE EXTINGUISHER CABINET —
INSTAL L TO ALIGN BOTTOM OF CABINET W/ CORRIDOR LEAN
RAIL
Efl FIREPLACE — SEE SPECIFICATION.
Efl ROOF BELOW — REFER TO ROOF PLAN ON SHEET A2. FOR
ROOF NOTES AND DIMENSIONS.
❑
7 CORRIDOR BULKHEAD /PILASTER — SEE 3/A5.08 & 4/A5.08.
® HORIZONTAL RECESSED MAILBOXES BY SALISBURY INDUSTRIES.
EflWASHER AND DRYER UNIT W/ WALL UTILITY PACK AND
OVERFLOW PAN.
10 12" DEEP CLOSE MESH UTILITY SHELF.
NOTE.- REFER TO SHEETS A4,01 THRU A4,43
FOR ENLARGED RESIDENT UNIT PLANS,
TYPICAL WALL TRIM LEGEND
HANDRAIL
SEE 4/A5,08
LEAN RAIL (CHAIR RAIL)
SEE 3/A5,08
N
KEY PLAN "(5`
NOT TO SCALE s
1111111
Charles E. Jarrell Mechanical
20'_6 1/2"
Contractors
>1
4208 Rider Trail North
I
4'_3" 7' -5 1 /2" 4' -3" ' -6 5' 2" 5' -2 1 /2" 5' 2" ' -6 4' -3" 7' -5 1 /2" 4' -3"
EQ. EQ.
11' -6 1 /4" 9' -0 3/4" 11' -6 1/4'
l l
E
0' -6 3/4
' E.
Austin
128 Millwell Drive
Carolinas
Maryland Heights, MO 63043
s
Ph:(314) 739 -7744
New York
'p�,1 PARTIAL THIRD FLOOR PLAN - NE
SCALE : 1/8" = V -0"
GENERAL NOTES (ENLARGED PLANS):
1. ALL DIMENSIONS ARE TO THE FACE OF DRYWALL UNLESS
NOTED OTHERWISE.
2. REFER TO SHEETS A2.01 —A2.05 OVERALL FLOOR PLANS
FOR FOR MORE INFORMATION.
3. REFER TO A2.01 -2.24 FLOOR PLANS FOR WINDOW
LOCATIONS. REFER TO BUILDING ELEVATIONS FOR WINDOW
TYPES.
4. REFER TO DOOR SCHEDULE SHEET A8.01 AND DOOR
DETAILS SHEET A8.03; REFER TO WINDOW TYPES SHEET A8.04
AND WINDOW DETAILS SHEETS A8.05 -8.06 FOR MORE
INFORMATION.
5. REFER TO ROOM FINISH SCHEDULE ON SHEET A9.01 FOR
MORE INFORMATION.
6. VERIFY ROUGH FRAMING REQUIREMENTS FOR ALL BATH &
SHOWER UNITS.
7. ALL DOORS THIS SHEET TO BE 4" OFF ADJACENT WALL AT
HINGE JAMB AND 18" CLEAR FROM PERPENDICULAR WALL AT
STRIKE JAMB U.N.O. EXCEPT AT POCKET DOORS (SEE
DETAILS).
8. PROVIDE BLOCKING IN WALL AT ALL RESIDENT TOILETS FOR
FUTURE REAR GRAB BAR.
9. DRYWALL TO RUN CONTINUOUS BEHIND TUB AND /OR
SHOWER UNITS AT RATED WALLS.
10. SEE SHEET A8.06 FOR WALL CONSTRUCTION AT POCKET
DOORS.
KEYED NOTES (ENLARGED PLANS):
[1] LEAN RAIL 0 2'- 107A.F.F. (REFER TO — /A6.06)
Efl CONTINUOUS SLIDING ROD W/ 12" WIRE SHELF ABOVE
(CLOSETMAID OR EQUAL). INSTALL SHELF 0 5' -6" A.F.F.
TYPICAL (4' -6" A.F.F. IN A.DA COMPLIANT UNITS).
30 (5) 12" DEEP (24' DEEP AT ROOM JGG11) CLOSE MESH
WIRE SHELVES. (CLOSETMAID OR EQUAL). INSTALL EQUALLY
SPACED FROM 1' -6" A.F.F. TO 5' -6" A.F.F. TYPICAL
® SEMI — RECESSED, RATED FIRE EXTINGUISHER CABINET —
INSTAL L TO ALIGN BOTTOM OF CABINET W/ CORRIDOR LEAN
RAIL
Efl FIREPLACE — SEE SPECIFICATION.
Efl ROOF BELOW — REFER TO ROOF PLAN ON SHEET A2. FOR
ROOF NOTES AND DIMENSIONS.
❑
7 CORRIDOR BULKHEAD /PILASTER — SEE 3/A5.08 & 4/A5.08.
® HORIZONTAL RECESSED MAILBOXES BY SALISBURY INDUSTRIES.
EflWASHER AND DRYER UNIT W/ WALL UTILITY PACK AND
OVERFLOW PAN.
10 12" DEEP CLOSE MESH UTILITY SHELF.
NOTE.- REFER TO SHEETS A4,01 THRU A4,43
FOR ENLARGED RESIDENT UNIT PLANS,
TYPICAL WALL TRIM LEGEND
HANDRAIL
SEE 4/A5,08
LEAN RAIL (CHAIR RAIL)
SEE 3/A5,08
N
KEY PLAN "(5`
NOT TO SCALE s
1111111
Charles E. Jarrell Mechanical
Design
Contractors
>1
4208 Rider Trail North
Engineer
Earth City, MO 63045
[
Ph:(314) 291 -0100
Foc(314) 291 -2803
Electrical
ARCHITECTS
Austin
128 Millwell Drive
Carolinas
Maryland Heights, MO 63043
Denver
Ph:(314) 739 -7744
New York
Fax:(314) 739 -0717
St. Louis:
319 North 4th Street
Suite 1000
St. Louis, MO 63102
#am .i1412.Y1 --52W
/ixr J1412J1 -M78
Project Team:
General
Paric Corporation
Contractor
1001 Boardwalk Springs
Place
O'Fallon, MO 63366
Ph:(636) 561 -9500
Faha(636) 561 -9501
Civil
The Schneider Corporation
Engineer
8901 Otis Avenue
Indianapolis, IN 46216
Ph:(317) 826 -7100
Fax:(317) 826 -7200
Structural
Alper Audi, Inc.
Engineer
1804 Borman Circle Drive
St. Louis, MO 63146
Ph:(314) 432 -6600
Fmc(314) 432 -8630
Mechanical
Charles E. Jarrell Mechanical
Design
Contractors
Engineer
4208 Rider Trail North
Engineer
Earth City, MO 63045
Ph:(314) 291 -0100
Foc(314) 291 -2803
Electrical
Bell Electrical Contractors
Design
128 Millwell Drive
Engineer
Maryland Heights, MO 63043
Ph:(314) 739 -7744
Fax:(314) 739 -0717
Plumbing
Tennill and Associates
Design
177 Chesterfield Industrial
Engineer
Blvd.
Engineer
Chesterfield, MO 63005
Ph:(636) 537 -3999
Fox:(536) 537 -3998
Fire
Fire Protection Systems
Protection
4316 Bridgeton Industrial
Design
Drive
Engineer
Bridgeton, MO 63044
Ph:(314) 739 -1400
F=x 314) 739 -6401
Food Service Dennis G. Glore, Inc.
Designer: P.O. Box 200
Eureka, MO 63025
Ph:(636) 938 -7887
Ph:(638) 938-0590
Professional Seal: t•�•'��"��xl�.,
0�t..Q o.
. No. AR10000256
r •
w • ..w.r..w i
•
s STATE OF
10 e1v 'ti
� ♦,,,,fir ` •••.......
t
The ProfassWid kWAeWs seal affixed to this sheet applies only to
the material and items shown an this sheet N drawing%
instruments or other documents not exhibiting this seal shall not be
considered prepared by this architect and this architect expressly
declaims any and all responsibility for such plans, drawings or
documents not exhibiting this eed.
C
0
� U
0
°d M c�
0
cc
IL
This drawing and details on it are the sole property
of the architect and may be used for this specific
project only. It shall not be loaned, copied or
reproduced, in whole or in part, or for any other
purpose or project without the written consent of the
architect.
No. Revision Description Date
Sheet Title:
PARTIAL
THIRD
FLOOR PLAN — NE
Project um er: Sheet Number:
05267
Drawn y:
KS, AI
Issue Date: A2021
July 12, 2006