Loading...
HomeMy WebLinkAboutA001.0SUMP w/ CHECK VALVE, VERIFY LOCATION OPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATIONPROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE FURNACE PER MECHANICAL PLANS WATER HEATER, PER SPEC OPT. WATER SOFTENER, PER SPECRADON VENT PER CODE, VERIFY LOCATION PERIMETER DRAIN, PER SPEC UP 7 RISERS HANDRAIL, PER CODE1234567 POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS12345678 FLOOR DRAIN, VERIFY LOCATION OPT\PROUGH IN BATH POST & BEAM PER STRUCTURAL PLANS ADD RISER W/ OPT. 9'-0" POUR 4140 SL & EGRESS WELL #1, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS \A1;23'-0"\A1;10'-7{\H0.75x;\S1#2;}" \A1;10'-3{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}"\A1;16'-3" \A1;11'-4" \A1;18'-3{\H0.75x;\S1#2;}" \A1;18'-11{\H0.75x;\S1#2;}"\A1;19'-8{\H0.75x;\S1#2;}" \A1;12'-1" \A1;6'-1" \A1;4'-5{\H0.75x;\S1#4;}" \A1;7'-0" \A1;2'-11{\H0.75x;\S3#4;}" \A1;2'-7{\H0.75x;\S1#4;}"\A1;20'-6{\H0.75x;\S1#2;}"\A1;1'-5{\H0.75x;\S1#2;}" \A1;2'-7{\H0.75x;\S1#2;}" \A1;48'-7" - OVERALL \A1;31'-9{\H0.75x;\S1#2;}" \A1;16'-9{\H0.75x;\S1#2;}" \A1;19'-3{\H0.75x;\S3#4;}" \A1;12'-5{\H0.75x;\S3#4;}" \A1;6'-4" \A1;25'-5{\H0.75x;\S1#2;}" \A1;7'-5{\H0.75x;\S1#2;}" \A1;10'-10" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) \A1;33'-7{\H0.75x;\S1#2;}" \A1;29'-7{\H0.75x;\S1#2;}" \A1;48'-7" - OVERALL \A1;20'-1" \A1;10'-6" \A1;18'-0" \A1;64'-7" - OVERALL \A1;30'-11{\H0.75x;\S1#2;}" \A1;64'-7" - OVERALL \A1;11'-11{\H0.75x;\S1#2;}" \A1;5'-0{\H0.75x;\S1#2;}" \A1;1'-9"\A1;2'-6{\H0.75x;\S1#2;}"\A1;8'-3"\A1;2'-2"\A1;16'-3" \A1;8'-11{\H0.75x;\S1#2;}" \A1;1'-9{\H0.75x;\S1#2;}" \A1;1'-8" \A1;5'-3{\H0.75x;\S1#2;}" \A1;11'-11{\H0.75x;\S1#2;}"\A1;3'-3"\A1;1'-9{\H0.75x;\S1#2;}" \A1;3{\H0.75x;\S1#2;}" \A1;47'-7" TO CORNER \A1;7'-4" \A1;6'-1{\H0.75x;\S1#2;}" \A1;12'-10" \A1;1'-7{\H0.75x;\S1#2;}"\pxql;2/8 2A2 B.1 1A2 B.1 1A2 B.1 2A2 B.1 3A2 B.2 4A2 B.2 4A2 B.2 BASEMENT UNFINISHEDSLAB (SEE STRUCTURAL PLANS) 3A2 B.2 SLAB/UNEXCAVATED (SEE STRUCTURAL PLANS)HVACSLOPEOPT. GAS VALVE GAS VALVE UNEXCAVATED(SEE STRUCTURAL PLANS)CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS)CONCRETE SLABA0.01 FOUNDATION - BASEMENTMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019 PROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Allison II 2377.300Home for * Market Home *, 6838-01200#213026 Copper Run Boulevard, Carmel, IN 46074BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 03/03/20 Adam Schriner