Loading...
HomeMy WebLinkAboutGN000.2AFF\PA/C\PALT\PARCH\PBSMT\PBLK\PBLKG\PBD\PBLDG\PCAB\PCPT\PCSMT\PCLG\PCIR\PCIRC\PCLR\PCOL\PCMU\PCONC\PCONST\PCONT\PCJ\PCF\PCY\PDET\PDIA\PDIM\PDW\PDR\PDH\PDS\PELEC\PELEV\PEQ\PEXH\PEXT\PFO\PFIN\PFPL\PFLR\PFD\PFLUOR\PFTG\PFND\PFUR\PGA\PGDO\PGFI\PGFI/WP\PGL\PGYP BD\PHDW\PHDR\PHVAC\PHGT\PHC\PHORIZ\PHB\PINSUL\PINT\PJT\PJST\PKIT\PLAV\PLT\PLNTL\PLVR\PMFR\PMAS\PMATL\PMAX\PMECH\PMC\PMTL\PMIN\PMIR\PMISC\PMOD\PMULL\PNTS\POC\POA\POH\POPT\PPB\PPNL\PPAR\PPED\PPL\PPVC\PPREFAB\PR\PREF\PREFR\PREINF\PR.A.G.\PREV\PR ABOVE FINISH FLOOR\PAIR CONDITIONING\PALTERNATE\PARCHITECT ARCHITECTURAL\PBASEMENT\PBLOCK\PBLOCKING\PBOARD\PBUILDING\PCABINET\PCARPET\PCASEMENT WINDOW\PCEILING\PCIRCLE\PCIRCUMFERENCE\PCLEAR CLEARANCE\PCOLUMN\PCONCRETE MASONRY UNIT\PCONCRETE\PCONSTRUCTION\PCONTINUOUS\PCONTROL OR CONSTRUCTION JOINT\PCUBIC FOOT\PCUBIC YARD\PDETAIL\PDIAMETER\PDIMENSION\PDISH WASHER\PDOOR\PDOUBLE HUNG\PDOWNSPOUT\PELECTRIC ELECTRICAL\PELEVATION\PEQUAL\PEXHAUST\PEXTERIOR\PFACE OF\PFINISH\PFIREPLACE\PFLOOR FLOORING\PFLO ABBREVIATIONS \pxi-2,l2,ql,t3;{\T0.9;1. ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NATIONAL ELECTRIC CODE (NEC). AND INTERNATIONAL RESIDENTIAL CODE (IRC). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NEC.\P2. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING UTILITY NOTES FLOORPLAN NOTES FOUNDATION NOTES\pxi-3,l3,t3;{\LGENERAL SPECIFICATIONS\P}\P1. WHERE DISCREPANCIES BETWEEN SOILS REPORT AND STRUCTURAL DRAWINGS OCCUR, CONTACT THE STRUCTURAL ENGINEER.\P2. FINISH GRADE SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE.\P3. SURFACE WATER TO DRAIN AWAY FROM STRUCTURE. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10 FEET (2% FOR IMPERVIOUS SURFACES)IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P4. GARAGE SLAB SHALL SLOPE A MIN. OF 2" AWAY FROM STR \A1;{\LGENERAL SPECIFICATIONS\P\P\pxi-2,l2,t2;}1. ALL ANGLED WALLS (OTHER THAN THOSE AT 90%%D) SHALL BE CONSIDERED TO BE AT 45%%D UNLESS NOTED OTHERWISE\P2. ALL NON-BEARING WALLS TO BE 2x4 STUDS AT 24" O.C. KITCHEN AND PULTE PLANNING CENTER WALLS, WHERE CABINETS ARE TO BE HUNG, SHALL BE FRAMED AT 16" O.C.\P3. PROVIDE A 1-3/8" OR LARGER SOLID CORE WOOD DOOR, SOLID CORE STEEL DOOR OR HONEYCOMB CORE STEEL DOOR, OR 20 MINUTE FIRE-RATED DOOR EQUIPPED WITH A SELF-CLOSING DEVICE BETWEEN GARAGE AND LIV UTILITY LEGEND SYMBOL SYMBOL TYPE ADDITIONAL NOITESADDRESS SIGN ADDRESS SIGN - VISIBLE FROM STREET. LETTERS OR NUMBERS FOR THE ADDRESS SHALL BE 4" MIN. IN HEIGHT AND 0.5" MIN. IN STROKE OF A CONTRASTING COLOR TO THE BACKGROUND ITSELF CHIMES - DOORBELLDETECTOR - HEAT CEILING MOUNTED HEAT DETECTOR TO BE HARD WIRED TO FIRE ALARM SYSTEM (INSTALL PER CODE) DETECTOR - SMOKE/CARBON MONOXIDE COMBINATION UL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DETECTOR - CARBON MONOXIDE UL APPROVED CEILING MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DETECTOR - SMOKE UL APPROVED CEILING MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DISCONNECT - SWITCHEDFAN - CEILING W/ LIGHT FAN BOX PER CODE. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL) FAN - EXHAUST EXHAUST TO EXTERIORFAN - EXHAUST W/ LIGHT EXHAUST TO EXTERIORLIGHT - CEILINGLIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-48X9LIGHT - FLUORESCENT-UNDER CAB-14LIGHT - RECESSED OR ALT. FIXTURE TYPELIGHT - RECESSED-VAPOR PROOF OR ALT. FIXTURE TYPE LIGHT - WALLLIGHT - WALL-PULL CHAINMETER - ELECTRIC VERIFY LOCATION IN FIELDOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - FLOOROUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONE CAT 5EOUTLET - TV RG-6OUTLET - WATERPROOF-GFIPANEL - ELECTRIC VERIFY LOCATION IN FIELDPANEL - ELECTRIC-RECESSED VERIFY LOCATION IN FIELDPANEL - MEDIA-RECESSED VERIFY LOCATION IN FIELDSWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAYSWITCH - FOUR WAYSWITCH - PUSH BUTTONTHERMOSTAT THERMOSTAT SHALL BE PROGRAMMABLEHOSE BIBBWATER SERVICEGAS VALVEGAS METERRETURN AIR GRILLEWATER METERWIRELESS ACCESS POINT HS/C C S PC 14RV PCE220VDW GFIGFI PHTVWP/GFI SDISPS3SS4 THBOPT.\PWATER LINE GAS VALVEGR.A.G.W SCHEDULE of AREAS BASE HOUSE - HEATED FIRST FLOOR 1829 SECOND FLOOR 1508 TOTAL BASE HEATED 3337 BASE HOUSE - UNDER ROOF GARAGE - 3 CAR FRONT ENTRY 609 GARAGE - 2 CAR FRONT ENTRY 609 GARAGE - 2 CAR SIDE ENTRY 609 GARAGE - 3 CAR SIDE ENTRY 804 BASEMENT 1251 GARAGE EXTENSION OPTION 78 TOTAL BASE UNDER ROOF 2438 BASE OPTIONS - HEATED SUNROOM 168 FINISHED BASEMENT OPTIONS FINISHED BASEMENT 672 ADDITIONAL AREA W/ SUNROOM 146 MECHANICAL and STORAGE 564 BASE OPTIONS BASEMENT / SUNROOM 153 COVERED PORCH 168 WOOD DECK 168 CONCRETE PATIO 168 LIGHT & VENT SCHEDULE ROOM NAME AREA REQUIRED SUPPLIED LIGHT VENT LIGHT VENT GATHERING RM / CAFE / KITCHEN 683.56 54.68 27.34 82.2 34.2 DINING 160.00 12.80 6.40 27.4 11.8 GAME ROOM 474.12 37.93 18.96 18 + ARTIF. 6.3 + MECH. OWNER'S SUITE 238.21 19.06 9.53 23.4 10.0 OWNER'S BATH 98.01 7.84 3.92 5.5 + ARTIF.MECH. BEDROOM 2 222.00 17.76 8.88 23.4 10 BEDROOM 3 167.92 13.43 6.72 26.5 11.3 BEDROOM 4 169.84 13.59 6.79 23.4 10 BATH 2 67.93 5.43 2.72 ARTIF.MECH. LAUNDRY 57.83 4.63 2.31 ARTIF.MECH. FLEX OPTION 160.01 12.80 6.40 27.4 11.8 BEDROOM 4 OPTION 154.87 12.39 6.19 23.4 10 LOFT OPTION 198.91 15.91 7.96 23.4 10 BATH 3 OPTION 40.66 3.25 1.63 ARTIF.MECH. FINISHED BASEMENT OPTION 585.38 46.83 23.42 ARTIF.MECH. FINISHED BASEMENT W/ SUNROOM OPTION 724.42 57.95 28.98 ARTIF.MECH. BEDROOM OPTION 7 127.57 10.21 5.10 12.2 6.7 BEDROOM OPTION 7 W/ SUNROOM 237.69 19.02 9.51 12.2 + ARTIF. 6.7 + MECH. BATH OPTION 7 41.67 3.33 1.67 ARTIF.MECH.{\Fsimplex|c0;\W0.7;ARTIF. = ARTIFICIAL LIGHT SUPPLIED\PMECH. = MECHANICAL VENTILATION SUPPLIED\PTHIS TABLE SHOWS CALCULATIONS THAT APPLY FOR ALL ELEVATIONS UNLESS NOTED OTHERWISE}Midwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019 PROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Allison II 2377.300Home for * Market Home *, 6838-01200#213026 Copper Run Boulevard, Carmel, IN 46074CC.02 NOTES - SCHEDULES AND LEGENDS03/03/20 Adam Schriner