Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
I40137449.12_Copper_Run
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). February 4,2020 Liu, Xuegang Pages or sheets covered by this seal: I40137449 thru I40137491 My license renewal date for the state of Indiana is July 31, 2020. 12_Copper_Run 12 Copper Run IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE01 Truss Type GABLE Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137449 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:01:50 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-o9x4qAE0flMjB8lQc57pgGtBrA3LYmX8MEHi_OzoZaV Scale = 1:60.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 34 35 2x4 3x4 4x6 2x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-5-019-5-0 -0-11-0 0-11-0 9-8-8 9-8-8 19-5-0 9-8-8 20-4-0 0-11-0 1-3-09-4-11-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.15 0.07 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 316 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 9-26 REACTIONS.All bearings 19-5-0. (lb) - Max Horz 33=186(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 33, 18, 28, 29, 30, 31, 23, 22, 21, 20 except 32=-112(LC 10), 19=-106(LC 11) Max Grav All reactions 250 lb or less at joint(s) 33, 18, 26, 27, 28, 29, 30, 31, 32, 25, 23, 22, 21, 20, 19 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 7-8=-124/263, 8-9=-132/276, 9-10=-132/276, 10-11=-124/263 WEBS 9-26=-284/109 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 6-8-8, Corner(3R) 6-8-8 to 12-8-8, Exterior(2N) 12-8-8 to 17-4-0, Corner(3E) 17-4-0 to 20-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 18, 28, 29, 30, 31, 23, 22, 21, 20 except (jt=lb) 32=112, 19=106. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE02 Truss Type GABLE Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137450 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:01:51 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-GLUS2WEeQ3UapIKcApe2CTQN0aQwHDgIbu1GWqzoZaU Scale = 1:41.3 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 12-5-812-5-8 -0-11-0 0-11-0 6-2-12 6-2-12 12-5-8 6-2-12 13-4-8 0-11-0 1-3-06-5-51-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.05 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 158 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 12-5-8. (lb) - Max Horz 24=134(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 14, 20, 21, 22, 18, 17, 16, 15 except 24=-108(LC 6), 23=-108(LC 7) Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-2-12, Exterior(2N) 2-2-12 to 3-2-12, Corner(3R) 3-2-12 to 9-2-12, Exterior(2N) 9-2-12 to 10-2-12, Corner(3E) 10-2-12 to 13-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 20, 21, 22, 18, 17, 16, 15 except (jt=lb) 24=108, 23=108. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE03 Truss Type GABLE Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137451 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:01:53 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-DkcDTCGuygkI2cT?HEhWIuVjUO6Ml6Qa2CWNajzoZaS Scale = 1:41.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 25 26 2x4 3x4 4x6 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-7-013-7-0 -0-11-0 0-11-0 6-9-8 6-9-8 13-7-0 6-9-8 14-6-0 0-11-0 1-3-06-10-151-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.05 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 180 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-7-0. (lb) - Max Horz 24=-142(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 7-19=-252/68 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 3-9-8, Corner(3R) 3-9-8 to 9-9-8, Exterior(2N) 9-9-8 to 11-6-0, Corner(3E) 11-6-0 to 14-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE05 Truss Type Common Supported Gable Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137452 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:01:54 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-hwAbgYHWj_t9gl2BrxClq62tNnQ8UazkHsFw79zoZaR Scale = 1:75.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 39 38 37 36 35 34 33 32 31 30 2928 27 26 25 24 23 22 21 2x4 3x4 3x4 4x6 3x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 32-11-032-11-0 -0-11-0 0-11-0 16-5-8 16-5-8 32-11-0 16-5-8 1-1-012-0-111-1-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.08 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.01 (loc) 1 1 21 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 608 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 20-21: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 11-30,10-31,12-28: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 11-30, 10-31, 9-33, 12-28, 13-27 REACTIONS.All bearings 32-11-0. (lb) - Max Horz 39=225(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 39, 21, 31, 33, 34, 35, 36, 37, 28, 27, 26, 25, 24, 23, 22 except 38=-107(LC 10) Max Grav All reactions 250 lb or less at joint(s) 39, 21, 31, 33, 34, 35, 36, 37, 38, 28, 27, 26, 25, 24, 23, 22 except 30=262(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 9-10=-167/256, 10-11=-189/291, 11-12=-189/291, 12-13=-167/256 WEBS 11-30=-273/140 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 13-5-8, Corner(3R) 13-5-8 to 19-5-8, Exterior(2N) 19-5-8 to 29-9-12, Corner(3E) 29-9-12 to 32-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 39, 21, 31, 33, 34, 35, 36, 37, 28, 27, 26, 25, 24, 23, 22 except (jt=lb) 38=107. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE06 Truss Type Common Supported Gable Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137453 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:01:56 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-dJIL5DInFb7tv3CZzMEDvX7Bmb4kyS01kAk1B2zoZaP Scale = 1:84.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 40 39 38 37 36 35 34 33 32 31 3029 28 27 26 25 24 23 22 21 2x4 2x4 3x4 4x6 3x4 3x6 4x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 34-10-034-10-0 16-0-14 16-0-14 34-10-0 18-9-3 3-0-913-9-21-3-08.00 12 Plate Offsets (X,Y)-- [21:Edge,0-2-8], [32:0-1-14,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.31 0.20 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 21 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 763 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 10-31,9-33,8-34,11-30,12-28: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-31, 9-33, 8-34, 7-35, 11-30, 12-28, 13-27 REACTIONS.All bearings 34-10-0. (lb) - Max Horz 40=-266(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 40, 31, 33, 34, 35, 36, 37, 38, 39, 30, 28, 27, 26, 25, 24, 23 except 21=-194(LC 7), 22=-144(LC 6) Max Grav All reactions 250 lb or less at joint(s) 40, 33, 34, 35, 36, 37, 38, 39, 30, 28, 27, 26, 25, 24, 23 except 21=274(LC 8), 31=323(LC 10), 22=325(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 7-8=-177/272, 8-9=-206/319, 9-10=-225/350, 10-11=-225/350, 11-12=-206/319, 12-13=-177/272, 19-20=-284/268 WEBS 10-31=-333/175 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-1-4 to 3-1-4, Exterior(2N) 3-1-4 to 13-0-14, Corner(3R) 13-0-14 to 19-0-14, Exterior(2N) 19-0-14 to 31-8-12, Corner(3E) 31-8-12 to 34-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 40, 31, 33, 34, 35, 36, 37, 38, 39, 30, 28, 27, 26, 25, 24, 23 except (jt=lb) 21=194, 22=144. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE07 Truss Type Monopitch Supported Gable Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137454 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:01:57 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-5VsjIZJP0vFjXDnmW4lSSkgF7?PuhpQAzqUajUzoZaO Scale = 1:80.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 12 3 4 5 6 7 13 12 11 10 9 8 14 3x4 2x4 4x6 6x6 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 -0-11-0 0-11-0 9-9-8 9-9-8 5-7-1012-1-158.00 12 Plate Offsets (X,Y)-- [7:0-3-14,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.72 0.27 0.65 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 -0.00 (loc) 1 2 8 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 260 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-13: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 6-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-8, 6-9, 5-10, 6-8 REACTIONS.All bearings 9-9-8. (lb) - Max Horz 13=323(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 13, 11, 12 except 8=-1177(LC 7), 9=-789(LC 8) Max Grav All reactions 250 lb or less at joint(s) 13, 10, 11, 12 except 8=906(LC 8), 9=1225(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-151/318, 5-6=-185/354 BOT CHORD 12-13=-295/206, 11-12=-295/206, 10-11=-295/206, 9-10=-295/206, 8-9=-295/206 WEBS 6-9=-1282/784, 6-8=-869/1211 NOTES-(10-11) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 1-9-8, Exterior(2N) 1-9-8 to 6-7-12, Corner(3E) 6-7-12 to 9-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 11, 12 except (jt=lb) 8=1177, 9=789. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE08 Truss Type GABLE Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137455 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:01:58 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-ZhQ6WvK1nDNa9NMy4nGh?yDYqOn4QPhKCTD8GwzoZaN Scale = 1:17.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 7 6 5 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-7-120-7-12 5-3-84-7-12 -0-11-0 0-11-0 5-3-8 5-3-8 0-9-02-6-30-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.21 0.14 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 5-6 5-6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=314/0-3-8, 5=150/0-1-8 Max Horz 6=54(LC 6) Max Uplift 6=-41(LC 6), 5=-20(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-261/279 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE09 Truss Type Piggyback Base Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137456 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:01:59 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-1tzUjFLfYWVRmXx8eUowX9lXco079g9TQ7zhoNzoZaM Scale = 1:80.8 1 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 12 23 24 25 26 27 3x6 8x8 3x6 4x6 12x12 3x6 2x4 4x6 3x6 3x6 3x6 4x10 5x12 2x4 6x8 6x8 3x8 2x4 3x6 3x4 8-3-88-3-8 16-4-88-1-0 23-0-06-7-8 29-2-106-2-10 35-5-36-2-10 35-11-00-5-13 39-11-54-0-6 44-8-04-8-10 -0-11-0 0-11-0 8-3-8 8-3-8 16-4-8 8-1-0 23-0-0 6-7-8 29-2-10 6-2-10 35-5-3 6-2-10 39-11-5 4-6-2 44-8-0 4-8-10 1-1-012-0-01-3-04-7-212-0-08.00 12 Plate Offsets (X,Y)-- [5:0-5-12,0-2-0], [9:0-5-8,0-2-8], [11:0-3-0,0-1-8], [17:0-6-4,0-3-12], [21:0-2-8,0-1-8], [22:Edge,0-10-2], [22:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.98 0.60 0.89 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.23 0.08 (loc) 21-22 21-22 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 212 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-19,5-19: 2x4 SPF No.2, 2-22,11-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-5-14 max.): 5-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 14-16,13-14. WEBS 1 Row at midpt 4-19, 5-19, 6-16, 9-14, 9-13 REACTIONS.All bearings 0-3-8 except (jt=length) 13=9-0-8, 12=9-0-8. (lb) - Max Horz 22=217(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 13, 14 except 12=-409(LC 23) Max Grav All reactions 250 lb or less at joint(s) 12 except 22=1385(LC 1), 13=647(LC 1), 14=1917(LC 1), 14=1917(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1765/6, 4-5=-1289/60, 5-6=-1391/64, 6-7=-682/64, 7-9=-682/64, 9-10=-47/722, 10-11=-30/739, 2-22=-1308/40, 11-12=-33/450 BOT CHORD 21-22=-275/493, 19-21=-104/1361, 6-17=0/461, 16-17=-87/1396, 14-16=-447/39, 13-14=-473/38 WEBS 4-21=0/268, 4-19=-556/151, 5-19=-255/120, 17-19=-54/1181, 5-17=-66/676, 6-16=-1069/43, 7-16=-403/110, 9-16=-71/1700, 9-14=-1798/72, 10-13=-314/150, 2-21=0/993, 11-13=-602/31 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-1-9, Exterior(2R) 12-1-9 to 20-7-7, Interior(1) 20-7-7 to 31-2-4, Exterior(2R) 31-2-4 to 39-11-5, Interior(1) 39-11-5 to 41-6-4, Exterior(2E) 41-6-4 to 44-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 2 = 8% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 14 except (jt=lb) 12=409. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss GE10 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137457 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:00 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-V4XsxbLHJqdIOgWLCCJ94NIspCSNuKScfniEKpzoZaL Scale = 1:30.2 1 2 3 4 7 6 5 8 9 2x4 2x4 2x4 2x4 2x4 2x4 2x4 7-9-117-9-11 7-9-11 7-9-11 5-2-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.16 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 7-9-11. (lb) - Max Horz 1=134(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 7=283(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-4-2 to 3-4-2, Exterior(2N) 3-4-2 to 4-8-7, Corner(3E) 4-8-7 to 7-8-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 7) Non Standard bearing condition. Review required. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss M02 Truss Type MONOPITCH Qty 6 Ply 1 12 Copper Run Job Reference (optional) I40137458 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:00 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-V4XsxbLHJqdIOgWLCCJ94NIsFCRDuKScfniEKpzoZaL Scale = 1:17.2 1 2 3 5 4 2x4 3x6 2x4 5-3-85-3-8 -0-11-0 0-11-0 5-3-8 5-3-8 0-9-02-6-30-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.34 0.23 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.00 (loc) 4-5 4-5 l/defl >999 >888 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=271/0-3-8, 4=193/0-1-8 Max Horz 5=54(LC 6) Max Uplift 5=-27(LC 6), 4=-21(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss M03 Truss Type MONOPITCH Qty 2 Ply 1 12 Copper Run Job Reference (optional) I40137459 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:01 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-_G5E8xMv48l90q4XlvqOcar_6clYdmymuRSosFzoZaK Scale = 1:20.1 1 2 3 4 7 6 5 8 9 2x4 3x6 2x4 3x6 2x4 0-7-120-7-12 7-3-86-7-12 -0-11-0 0-11-0 7-3-8 7-3-8 0-9-03-2-30-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.53 0.35 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.15 0.00 (loc) 5-6 5-6 l/defl >999 >489 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=387/0-3-8, 5=237/0-1-8 Max Horz 6=73(LC 6) Max Uplift 6=-39(LC 6), 5=-27(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-409/404 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 2-10-13, Exterior(2R) 2-10-13 to 7-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss M04 Truss Type MONOPITCH Qty 6 Ply 1 12 Copper Run Job Reference (optional) I40137460 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:02 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-SSfcMHNXqRt0d_fjJdLd9oNEp080MDhv75BLPizoZaJ Scale = 1:17.2 1 2 3 4 7 6 5 2x4 3x6 2x4 2x4 2x4 0-7-120-7-12 5-3-84-7-12 -0-11-0 0-11-0 5-3-8 5-3-8 0-9-02-6-30-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.21 0.14 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 5-6 5-6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=314/0-3-8, 5=150/0-1-8 Max Horz 6=54(LC 6) Max Uplift 6=-41(LC 6), 5=-20(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-261/279 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss M07 Truss Type Monopitch Qty 6 Ply 1 12 Copper Run Job Reference (optional) I40137461 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:03 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-wfD?ZdOAbl?tF8EwtKssi?wJsPP55dd3Llxux8zoZaI Scale = 1:66.9 1 2 3 4 6 5 7 8 5x8 4x8 3x4 3x4 3x8 3x4 10-1-010-1-0 -0-11-0 0-11-0 5-0-8 5-0-8 10-1-0 5-0-8 5-7-1012-4-59-1-1212-4-58.00 12 Plate Offsets (X,Y)-- [4:0-3-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.58 0.47 0.28 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.54 -0.41 (loc) 5-6 5-6 8 l/defl >436 >219 n/a L/d 240 180 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF No.2, 2-6: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-5, 3-6 REACTIONS.(lb/size)6=459/0-3-8, 8=365/0-3-8 Max Horz 6=292(LC 7) Max Uplift 8=-124(LC 7) Max Grav 6=463(LC 18), 8=440(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-7=-119/338, 4-7=-119/338 WEBS 3-5=-270/212, 3-6=-254/94, 4-8=-443/167 NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 9-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=124. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss PB01 Truss Type GABLE Qty 9 Ply 1 12 Copper Run Job Reference (optional) I40137462 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:04 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-OrnNmyOoM37ktIp6R2N5EDSZcprzq68CaPgSTazoZaH Scale = 1:40.6 2 3 4 5 6 11 10 9 8 1 12 13 7 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 3x4 19-0-1119-0-11 9-6-6 9-6-6 19-0-11 9-6-6 6-4-40-1-40-1-88.00 12 Plate Offsets (X,Y)-- [2:0-1-15,0-1-8], [6:0-1-15,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.26 0.11 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-0-11. (lb) - Max Horz 1=110(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 11, 8, 6 except 1=-305(LC 17), 7=-260(LC 18) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 9 except 2=516(LC 17), 11=385(LC 17), 8=385(LC 18), 6=506(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-290/160, 5-8=-289/160 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-3-5 to 3-3-5, Exterior(2N) 3-3-5 to 6-6-6, Corner(3R) 6-6-6 to 12-6-6, Exterior(2N) 12-6-6 to 15-9-6, Corner(3E) 15-9-6 to 18-9-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11, 8, 6 except (jt=lb) 1=305, 7=260. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss PBE01 Truss Type GABLE Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137463 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:06 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-KEu7BeQ2ugNS6bzUYTQZJeYyLdXqI1ZV1j9ZYTzoZaF Scale = 1:42.0 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 2 3 4 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 1 28 29 15 4x6 3x4 3x4 2x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-0-1119-0-11 9-6-6 9-6-6 19-0-11 9-6-6 6-4-40-1-40-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.05 0.02 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 192 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-0-11. (lb) - Max Horz 1=110(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 15, 22, 23, 25, 26, 27, 20, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 1, 15, 2, 21, 22, 14, 23, 25, 26, 27, 20, 19, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-3-5 to 3-3-5, Exterior(2N) 3-3-5 to 6-6-6, Corner(3R) 6-6-6 to 12-6-6, Exterior(2N) 12-6-6 to 15-9-6, Corner(3E) 15-9-6 to 18-9-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 15, 22, 23, 25, 26, 27, 20, 19, 18, 17, 16. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T01 Truss Type COMMON Qty 5 Ply 1 12 Copper Run Job Reference (optional) I40137464 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:08 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Gc0ucKRIQHdAMv7tgtS1P3dCgQ2RmqEoV1efcLzoZaD Scale = 1:57.4 1 2 3 4 5 6 7 11 10 9 8 12 13 4x6 3x4 3x8 3x4 3x4 2x4 4x8 4x8 2x4 9-8-89-8-8 19-5-09-8-8 -0-11-0 0-11-0 3-10-4 3-10-4 9-8-8 5-10-4 15-6-12 5-10-4 19-5-0 3-10-4 20-4-0 0-11-0 1-3-09-4-11-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.44 0.72 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.34 0.02 (loc) 8-10 8-10 8 l/defl >999 >681 n/a L/d 240 180 n/a PLATES MT20 Weight: 83 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)11=829/0-3-8, 8=829/0-3-8 Max Horz 11=-186(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-686/78, 4-5=-686/78 BOT CHORD 10-11=-61/606, 8-10=0/558 WEBS 4-10=0/467, 3-11=-707/36, 5-8=-707/36 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-8-8, Exterior(2R) 6-8-8 to 12-8-8, Interior(1) 12-8-8 to 17-4-0, Exterior(2E) 17-4-0 to 20-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T01A Truss Type COMMON Qty 3 Ply 1 12 Copper Run Job Reference (optional) I40137465 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:08 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Gc0ucKRIQHdAMv7tgtS1P3dCdQ2YmrIoV1efcLzoZaD Scale = 1:57.4 1 2 3 4 5 6 10 9 8 7 11 12 4x6 2x4 3x4 3x8 3x4 3x4 2x4 4x8 4x8 9-8-89-8-8 19-3-89-7-0 -0-11-0 0-11-0 3-10-4 3-10-4 9-8-8 5-10-4 15-6-10 5-10-2 19-3-8 3-8-14 1-3-09-4-11-4-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.45 0.71 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.34 0.02 (loc) 9-10 9-10 7 l/defl >999 >668 n/a L/d 240 180 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=826/0-3-8, 7=758/Mechanical Max Horz 10=181(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-681/78, 4-5=-682/78 BOT CHORD 9-10=-72/596, 7-9=-2/548 WEBS 4-9=0/461, 3-10=-702/36, 5-7=-715/50 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-8-8, Exterior(2R) 6-8-8 to 12-8-8, Interior(1) 12-8-8 to 16-1-12, Exterior(2E) 16-1-12 to 19-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T02 Truss Type COMMON Qty 5 Ply 1 12 Copper Run Job Reference (optional) I40137466 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:09 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-lpaGqgSwBbl0z3i3DbzGxGAMQqQNVJ4xkhOD9ozoZaC Scale = 1:57.4 1 2 3 4 9 8 7 6 5 10 11 12 13 2x4 4x6 5x8 3x4 3x4 4x8 2x4 3x8 3x4 9-8-89-8-8 16-3-86-7-0 3-10-4 3-10-4 9-8-8 5-10-4 16-3-8 6-7-0 1-3-09-4-13-10-41-0-010.00 12 Plate Offsets (X,Y)-- [4:Edge,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.51 0.61 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.41 0.04 (loc) 8-9 8-9 11 l/defl >932 >465 n/a L/d 240 180 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-9: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=640/0-3-8, 11=628/0-3-8 Max Horz 9=152(LC 7) Max Uplift 11=-4(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-513/77, 3-4=-509/71 BOT CHORD 8-9=-126/485 WEBS 3-8=0/282, 2-9=-531/60, 4-8=0/301, 4-11=-632/17 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-8-8, Exterior(2R) 6-8-8 to 12-10-12, Exterior(2E) 12-10-12 to 15-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T03 Truss Type MONOPITCH Qty 2 Ply 1 12 Copper Run Job Reference (optional) I40137467 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:10 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-D?8e10TZyvutbDGGnIUVUUiWpEp_Eim5yL7mhEzoZaB Scale = 1:58.4 1 2 3 7 6 5 4 8 92x4 3x8 3x4 3x8 2x4 3x4 3x4 3x4 1-0-01-0-100-9-43-10-14 3-10-14 11-3-8 7-4-10 3-10-14 3-10-14 11-3-8 7-4-10 1-3-010-7-152-9-1410-7-1510.00 12 Plate Offsets (X,Y)-- [3:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.53 0.39 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.18 0.19 (loc) 5-6 5-6 9 l/defl >999 >734 n/a L/d 240 180 n/a PLATES MT20 Weight: 60 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-7: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-5 REACTIONS.(lb/size)7=440/0-3-8, 9=428/0-3-8 Max Horz 7=241(LC 10) Max Uplift 9=-141(LC 10) Max Grav 7=440(LC 1), 9=450(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BOT CHORD 6-7=-163/365, 5-6=-163/365 WEBS 5-8=-53/278, 3-8=-53/278, 2-5=-405/180, 2-6=0/285, 2-7=-488/0, 3-9=-450/165 NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 7-10-12, Exterior(2E) 7-10-12 to 10-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=141. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T06 Truss Type Common Qty 6 Ply 1 12 Copper Run Job Reference (optional) I40137468 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:11 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-hBi0EMUBjC0kDNrSL0?k0hFeue4mz5NEB?tKDgzoZaA Scale = 1:82.7 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 17 3x8 4x6 3x4 3x4 3x4 3x6 3x6 3x8 3x6 3x4 3x12 6x6 4x8 3x6 3x6 8-1-118-1-11 16-0-147-11-3 26-0-49-11-7 34-10-08-9-12 8-1-11 8-1-11 16-0-14 7-11-3 22-3-1 6-2-4 28-5-5 6-2-4 34-10-0 6-4-12 3-0-913-9-21-3-08.00 12 Plate Offsets (X,Y)-- [14:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.77 0.74 0.93 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.42 0.05 (loc) 10-12 10-12 9 l/defl >999 >989 n/a L/d 240 180 n/a PLATES MT20 Weight: 163 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-12,4-12,5-12: 2x4 SPF No.2, 1-15,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 3-12, 5-12, 7-9 REACTIONS.(lb/size)15=1382/0-3-8, 9=1382/Mechanical Max Horz 15=-266(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1440/52, 3-4=-1236/130, 4-5=-1194/136, 5-7=-1700/85, 7-8=-335/86, 1-15=-1307/22, 8-9=-308/78 BOT CHORD 14-15=-223/280, 12-14=-14/1124, 10-12=0/1193, 9-10=0/1396 WEBS 3-12=-352/159, 4-12=-47/825, 5-12=-550/171, 5-10=-27/418, 1-14=0/1103, 7-9=-1559/0 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 13-0-14, Exterior(2R) 13-0-14 to 19-0-14, Interior(1) 19-0-14 to 31-8-4, Exterior(2E) 31-8-4 to 34-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T07 Truss Type Common Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137469 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:12 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-9OGOSiVpUW8bqXQevjXzZvol42SLidnNQfctl7zoZa9 Scale = 1:73.0 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 17 3x8 4x6 3x8 12x12 3x4 3x8 3x6 3x6 3x6 3x6 12x12 3x4 8-4-08-4-0 16-5-88-1-8 24-7-08-1-8 32-11-08-4-0 -0-11-0 0-11-0 8-4-0 8-4-0 16-5-8 8-1-8 24-7-0 8-1-8 32-11-0 8-4-0 1-1-012-0-111-1-08.00 12 Plate Offsets (X,Y)-- [9:Edge,0-10-2], [9:0-1-12,0-0-0], [10:0-2-8,0-1-8], [14:0-2-8,0-1-8], [15:0-1-12,0-0-0], [15:Edge,0-10-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.99 0.59 0.54 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.24 0.04 (loc) 9-10 9-10 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 138 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-12: 2x4 SPF No.2, 2-15,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-12, 4-12 REACTIONS.(lb/size)15=1370/0-3-8, 9=1304/0-3-8 Max Horz 15=226(LC 7) Max Uplift 15=-3(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1740/27, 4-5=-1266/109, 5-6=-1268/109, 6-8=-1739/26, 2-15=-1292/49, 8-9=-1226/34 BOT CHORD 14-15=-206/530, 12-14=-39/1339, 10-12=0/1347, 9-10=-44/285 WEBS 5-12=-1/805, 6-12=-558/153, 6-10=0/262, 4-12=-549/151, 4-14=0/267, 2-14=0/963, 8-10=0/1067 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 13-5-8, Exterior(2R) 13-5-8 to 19-5-8, Interior(1) 19-5-8 to 29-9-4, Exterior(2E) 29-9-4 to 32-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The Fabrication Tolerance at joint 2 = 8%, joint 8 = 8% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T08 Truss Type Common Qty 4 Ply 1 12 Copper Run Job Reference (optional) I40137470 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:13 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-daqnf1VRFqGSSg?rSR2C66KwqRnaR41XeJMQIZzoZa8 Scale = 1:73.0 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 17 3x8 4x6 3x8 12x12 3x4 3x8 3x6 3x6 3x6 3x6 12x12 3x4 8-4-08-4-0 16-5-88-1-8 24-7-08-1-8 32-11-08-4-0 -0-11-0 0-11-0 8-4-0 8-4-0 16-5-8 8-1-8 24-7-0 8-1-8 32-11-0 8-4-0 1-1-012-0-111-1-08.00 12 Plate Offsets (X,Y)-- [9:Edge,0-10-2], [9:0-1-12,0-0-0], [10:0-2-8,0-1-8], [14:0-2-8,0-1-8], [15:0-1-12,0-0-0], [15:Edge,0-10-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.99 0.59 0.54 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.24 0.04 (loc) 9-10 9-10 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 138 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-12: 2x4 SPF No.2, 2-15,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-12, 4-12 REACTIONS.(lb/size)15=1370/0-3-8, 9=1304/0-3-8 Max Horz 15=226(LC 7) Max Uplift 15=-3(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1740/27, 4-5=-1266/109, 5-6=-1268/109, 6-8=-1739/26, 2-15=-1292/49, 8-9=-1226/34 BOT CHORD 14-15=-206/530, 12-14=-39/1339, 10-12=0/1347, 9-10=-44/285 WEBS 5-12=-1/805, 6-12=-558/153, 6-10=0/262, 4-12=-549/151, 4-14=0/267, 2-14=0/963, 8-10=0/1067 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 13-5-8, Exterior(2R) 13-5-8 to 19-5-8, Interior(1) 19-5-8 to 29-9-4, Exterior(2E) 29-9-4 to 32-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The Fabrication Tolerance at joint 2 = 8%, joint 8 = 8% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T08A Truss Type Roof Special Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137471 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:14 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-5mN9tNW307OJ4qa108ZReKt7Fr7rAV7gtz5_q?zoZa7 Scale = 1:81.7 1 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 12 23 24 3x4 4x6 5x8 3x4 2x4 2x4 3x6 8x10 2x4 4x8 3x8 5x6 4x8 6x8 3x4 3x6 3x8 3x6 5x12 4x8 4x6 1-3-0 1-3-0 2-3-8 1-0-8 7-4-8 5-1-0 12-5-8 5-1-0 21-8-15 9-3-7 27-0-7 5-3-7 32-11-0 5-10-9 -0-11-0 0-11-0 1-3-0 1-3-0 2-3-8 1-0-8 7-4-8 5-1-0 12-5-8 5-1-0 16-5-8 4-0-0 21-8-15 5-3-7 27-0-7 5-3-7 32-11-0 5-10-9 1-1-05-0-112-0-115-0-10-8-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [12:Edge,0-2-8], [19:0-5-12,0-3-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.89 0.59 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.47 0.09 (loc) 14-16 14-16 12 l/defl >999 >837 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 4-20,7-16: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 8-17,8-14: 2x4 SPF No.2, 2-22: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-15 oc purlins, except end verticals, and 2-0-0 oc purlins (4-1-0 max.): 10-11. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. Except: 1 Row at midpt 7-17 WEBS 1 Row at midpt 9-14 REACTIONS.(lb/size)12=1306/0-3-8, 22=1371/0-3-8 Max Horz 22=262(LC 7) Max Uplift 12=-3(LC 11), 22=-2(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1044/4, 3-4=-2195/86, 4-6=-1888/27, 6-7=-1528/75, 7-8=-1500/160, 8-9=-1529/161, 9-10=-1695/102, 10-11=-1320/34, 11-12=-1247/31, 2-22=-1313/14 BOT CHORD 21-22=-239/253, 18-19=-200/1991, 17-18=-52/1506, 7-17=-278/135, 13-14=0/1198 WEBS 3-21=-1308/77, 19-21=-120/1072, 3-19=-108/1350, 4-18=-517/153, 6-18=0/274, 6-17=-454/102, 14-17=0/756, 8-17=-135/812, 8-14=-101/686, 9-14=-498/192, 9-13=-64/308, 10-13=-1221/97, 11-13=0/1696, 2-21=0/899 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-2-4, Interior(1) 2-2-4 to 13-5-8, Exterior(2R) 13-5-8 to 19-5-8, Interior(1) 19-5-8 to 29-9-12, Exterior(2E) 29-9-12 to 32-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 22. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T09 Truss Type Roof Special Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137472 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:16 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-19VvI3YJXle1J8kP8ZbvjlyRJfn8eMTzLHa5uuzoZa5 Scale = 1:90.1 12 3 4 5 6 7 8 9 10 11 12 13 27 26 25 24 23 22 21 20 19 18 17 16 15 14 28 29 303x6 8x16 5x12 4x6 3x4 2x4 4x6 8x10 2x4 2x4 2x4 2x4 10x16 MT18HS 2x4 5x6 4x8 10x10 3x4 3x6 4x10 10x16 2x4 2x4 6x16 3x8 4x6 1-3-0 1-3-0 2-3-8 1-0-8 7-4-8 5-1-0 12-5-8 5-1-0 16-5-8 4-0-0 23-0-0 6-6-8 24-6-7 1-6-7 29-3-10 4-9-3 34-0-14 4-9-3 35-11-0 1-10-2 -0-11-0 0-11-0 1-3-0 1-3-0 2-3-8 1-0-8 7-4-8 5-1-0 12-5-8 5-1-0 16-5-8 4-0-0 23-0-0 6-6-8 24-6-7 1-6-7 29-3-10 4-9-3 34-0-14 4-9-3 35-11-0 1-10-2 1-1-06-8-112-0-111-0-04-7-20-8-00-8-06-8-18.00 12 7.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [8:Edge,0-3-8], [12:0-10-0,0-2-4], [15:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.98 0.73 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.49 -0.97 0.36 (loc) 18 19 14 l/defl >876 >439 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 186 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 8-10: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 4-25,7-21,9-19: 2x3 SPF No.2, 14-18: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 8-22,8-20,10-16,12-16: 2x4 SPF No.2, 8-18: 2x4 SPF 2100F 1.8E 2-27,13-14: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (2-2-0 max.): 10-12. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. Except: 1 Row at midpt 7-22 WEBS 1 Row at midpt 8-20 REACTIONS.(lb/size)27=1490/0-3-8, 14=1424/0-3-8 Max Horz 27=216(LC 7) Max Uplift 14=-15(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1141/0, 3-4=-2406/117, 4-6=-2092/20, 6-7=-1737/71, 7-8=-1700/149, 8-9=-5074/142, 9-10=-4934/21, 10-11=-4272/32, 11-12=-4272/32, 12-13=-1632/19, 2-27=-1427/8, 13-14=-1420/16 BOT CHORD 23-24=-290/2109, 22-23=-110/1676, 7-22=-270/132, 9-18=-386/180, 17-18=0/6131, 16-17=0/6132, 15-16=-5/1364 WEBS 3-26=-1437/121, 24-26=-193/1125, 3-24=-149/1474, 4-23=-512/185, 6-23=0/269, 6-22=-449/108, 20-22=0/1030, 8-22=-170/843, 8-20=-808/56, 18-20=0/1315, 8-18=-86/4545, 10-18=-2927/0, 10-16=-1985/0, 11-16=-301/89, 12-16=-7/3102, 12-15=-475/46, 2-26=0/986, 13-15=-1/1443 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-2-4, Interior(1) 2-2-4 to 13-5-8, Exterior(2R) 13-5-8 to 19-5-8, Interior(1) 19-5-8 to 31-0-14, Exterior(2R) 31-0-14 to 34-0-14, Exterior(2E) 34-0-14 to 35-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T09A Truss Type Roof Special Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137473 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:18 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-_XdgilZa3MulYSuoF_dNpA2q6STy6F2Gob3BzmzoZa3 Scale = 1:80.8 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 22 23 24 25 3x6 5x6 8x8 5x6 4x6 4x6 3x6 2x4 2x4 12x12 3x4 3x6 3x6 12x12 2x4 4x8 4x8 3x6 3x6 6x8 8-4-08-4-0 16-5-88-1-8 23-0-06-6-8 27-1-54-1-5 31-2-94-1-5 33-5-92-2-15 35-11-02-5-7 -0-11-0 0-11-0 8-4-0 8-4-0 16-5-8 8-1-8 22-0-7 5-6-15 23-0-0 0-11-9 27-1-5 4-1-5 31-2-9 4-1-5 33-5-9 2-2-15 35-11-0 2-5-7 1-1-08-4-112-0-111-0-04-7-28-4-18.00 12 7.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [9:0-3-0,0-1-12], [11:Edge,0-1-12], [13:0-2-8,0-1-8], [18:0-4-0,Edge], [19:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.83 0.71 0.94 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.50 0.20 (loc) 17 17 12 l/defl >999 >848 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 7-17: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-18,16-18,2-21: 2x4 SPF No.2, 6-18: 2x4 SPF 2100F 1.8E 11-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (2-10-13 max.): 6-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-18, 6-18 REACTIONS.(lb/size)21=1490/0-3-8, 12=1424/0-3-8 Max Horz 21=216(LC 7) Max Uplift 12=-15(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1928/20, 4-5=-1456/101, 5-6=-1413/108, 6-7=-3373/43, 7-8=-3384/41, 8-9=-1693/51, 9-10=-1952/46, 10-11=-1707/28, 2-21=-1412/44, 11-12=-1373/27 BOT CHORD 19-21=-281/523, 18-19=-97/1495, 15-16=0/2739, 14-15=0/2739, 13-14=-9/1435 WEBS 4-19=0/262, 4-18=-544/151, 5-18=-5/1058, 6-18=-3319/69, 16-18=0/3648, 6-16=0/1752, 8-16=-30/835, 8-14=-1381/0, 9-14=0/777, 10-14=-18/316, 10-13=-447/28, 2-19=0/1100, 11-13=-2/1404 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 13-5-8, Exterior(2R) 13-5-8 to 19-5-8, Interior(1) 19-5-8 to 28-2-9, Exterior(2R) 28-2-9 to 32-9-4, Exterior(2E) 32-9-4 to 35-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 2 = 0% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T10 Truss Type Piggyback Base Qty 6 Ply 1 12 Copper Run Job Reference (optional) I40137474 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:19 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-SkB2w5aCqg0cAbT_ph9cLNa_Ksk9ripP1FplVDzoZa2 Scale = 1:84.0 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 22 23 24 25 26 3x6 3x6 5x8 6x6 3x16 MT18HS 6x10 3x6 3x6 5x8 3x4 6x8 3x4 2x4 5x8 3x4 3x6 4x8 3x6 10x10 3x4 8-3-88-3-8 15-11-87-8-0 22-8-126-9-4 29-0-156-4-4 35-5-36-4-4 39-11-54-6-2 44-8-04-8-10 -0-11-0 0-11-0 8-3-8 8-3-8 16-4-8 8-1-0 22-8-12 6-4-4 29-0-15 6-4-4 35-5-3 6-4-4 39-11-5 4-6-2 44-8-0 4-8-10 1-1-012-0-01-3-04-7-27-4-148.00 12 3.56 12 Plate Offsets (X,Y)-- [2:0-4-4,Edge], [5:0-5-8,0-1-12], [9:0-5-12,0-2-0], [11:Edge,0-1-12], [12:Edge,0-1-8], [13:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.86 0.97 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.58 0.28 (loc) 18-20 18-20 12 l/defl >999 >923 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 189 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x4 SP 2400F 2.0E, 1-3: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-21: 2x6 SPF No.2, 11-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (2-11-0 max.): 5-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 18-20. WEBS 1 Row at midpt 6-16 REACTIONS.(lb/size)21=1841/0-5-8, 12=1771/Mechanical Max Horz 21=219(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3801/19, 4-5=-3313/12, 5-6=-2793/21, 6-7=-2540/0, 7-9=-2541/0, 9-10=-2269/9, 10-11=-2246/0, 2-21=-1895/94, 11-12=-1716/0 BOT CHORD 20-21=-293/603, 18-20=-133/3195, 17-18=-54/2583, 16-17=-45/2792, 14-16=0/1823, 13-14=0/1808 WEBS 4-18=-509/197, 5-18=0/1116, 5-17=-161/489, 6-16=-427/45, 7-16=-401/111, 9-16=-91/1131, 10-13=-308/38, 2-20=0/2635, 11-13=0/1736 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-1-9, Exterior(2R) 12-1-9 to 20-7-7, Interior(1) 20-7-7 to 31-2-4, Exterior(2R) 31-2-4 to 39-11-5, Interior(1) 39-11-5 to 41-6-4, Exterior(2E) 41-6-4 to 44-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Bearing at joint(s) 21 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss T11 Truss Type Piggyback Base Qty 3 Ply 1 12 Copper Run Job Reference (optional) I40137475 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:23 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-KVQZmSdiuuW1fDmm2XDYVDlfPT7ynWo?ysnye_zoZa_ Scale = 1:85.6 1 2 3 4 5 6 7 8 9 10 11 12 20 19 18 17 16 15 14 13 21 22 23 24 25 26 3x6 6x8 3x6 5x6 3x8 MT18HS 6x10 3x8 MT18HS 3x6 5x8 3x4 3x4 3x6 4x8 4x8 3x6 10x10 12x18 MT18HS 8-4-08-4-0 15-11-87-7-8 25-8-69-8-13 35-5-39-8-13 44-11-09-5-13 -0-11-0 0-11-0 8-4-0 8-4-0 16-4-8 8-0-8 22-8-12 6-4-4 29-0-15 6-4-4 35-5-3 6-4-4 40-0-6 4-7-3 44-11-0 4-10-10 45-11-0 1-0-0 1-1-012-0-01-1-04-7-27-4-148.00 12 3.56 12 Plate Offsets (X,Y)-- [2:0-4-4,Edge], [5:0-5-8,0-1-12], [9:0-3-12,0-2-0], [11:0-1-12,0-1-3], [13:Edge,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.86 0.91 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.28 -0.68 0.29 (loc) 16-17 16-17 13 l/defl >999 >787 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 183 lb FT = 20% GRIP 197/144 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x4 SP 2400F 2.0E, 1-3: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 15-17: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-20: 2x6 SPF No.2, 11-13: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-1-1 max.): 5-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 14-16. WEBS 1 Row at midpt 6-17, 7-14, 10-13 REACTIONS.(lb/size)20=1850/0-5-8, 13=1850/0-3-8 Max Horz 20=212(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3818/13, 4-5=-3359/4, 5-6=-2591/31, 6-7=-2736/0, 7-9=-1894/12, 9-10=-2339/0, 10-11=-420/32, 2-20=-1904/93, 11-13=-413/54 BOT CHORD 19-20=-284/622, 17-19=-118/3212, 16-17=-44/2802, 14-16=-12/2563, 13-14=0/1856 WEBS 4-17=-485/199, 5-17=0/1378, 6-17=-486/184, 7-16=0/445, 7-14=-1071/119, 9-14=0/936, 2-19=0/2635, 10-13=-2078/0 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-1-9, Exterior(2R) 12-1-9 to 20-7-7, Interior(1) 20-7-7 to 31-2-4, Exterior(2R) 31-2-4 to 39-8-2, Interior(1) 39-8-2 to 42-11-0, Exterior(2E) 42-11-0 to 45-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Bearing at joint(s) 20 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 2 12 Copper Run Job Reference (optional) I40137476 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:26 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-l46hOUfbBpvcWgVKjfnF7sN9JhHS_xMReq?cEJzoZZx Scale = 1:42.5 1 2 3 4 5 10 9 8 7 6111213141516 12x18 MT18HS 4x6 12x18 MT18HS 10x10 3x8 10x10 3x8 10x10 3-5-63-5-6 6-9-83-4-2 10-1-103-4-2 13-7-03-5-6 3-5-6 3-5-6 6-9-8 3-4-2 10-1-10 3-4-2 13-7-0 3-5-6 1-3-06-10-151-3-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-10-6], [5:Edge,0-10-6], [6:0-1-12,0-0-0], [7:0-3-8,0-5-0], [9:0-3-8,0-5-0], [10:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.94 0.35 0.66 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.09 0.01 (loc) 8-9 8-9 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 167 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-8,1-9,5-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-6 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=5767/0-5-8, 6=5801/0-5-8 Max Horz 10=124(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5768/0, 2-3=-4449/0, 3-4=-4449/0, 4-5=-5774/0, 1-10=-4922/0, 5-6=-4926/0 BOT CHORD 9-10=-18/370, 8-9=0/4368, 7-8=0/4373, 6-7=0/374 WEBS 3-8=0/5395, 4-8=-1480/0, 4-7=0/1801, 2-8=-1473/0, 2-9=0/1792, 1-9=0/4160, 5-7=0/4161 NOTES-(10-11) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1751 lb down at 1-9-12, 1751 lb down at 3-9-12, 1751 lb down at 5-9-12, 1751 lb down at 7-9-12, and 1751 lb down at 9-9-12, and 1751 lb down at 11-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 2 12 Copper Run Job Reference (optional) I40137476 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:26 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-l46hOUfbBpvcWgVKjfnF7sN9JhHS_xMReq?cEJzoZZx LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-10=-20 Concentrated Loads (lb) Vert: 11=-1751(F) 12=-1751(F) 13=-1751(F) 14=-1751(F) 15=-1751(F) 16=-1751(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss TG02 Truss Type COMMON GIRDER Qty 1 Ply 2 12 Copper Run Job Reference (optional) I40137477 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:28 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-hTERpAhrjR9Kl_fjr4pjCHSXvU_qSqRk58UjIBzoZZv Scale = 1:39.1 1 2 3 7 6 5 4 8 9 10 11 12 12x18 MT18HS 4x8 12x18 MT18HS 10x10 10x10 4-2-114-2-11 8-2-134-0-3 12-5-84-2-11 6-2-12 6-2-12 12-5-8 6-2-12 1-3-06-5-51-3-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-10-6], [3:Edge,0-10-6], [4:0-1-12,0-0-0], [7:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.81 0.29 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.08 0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 138 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=4074/0-3-8, 4=5076/0-5-8 Max Horz 7=116(LC 26) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-4112/0, 2-3=-4144/0, 1-7=-3372/0, 3-4=-3389/0 BOT CHORD 6-7=-55/456, 5-6=0/2253, 4-5=0/470 WEBS 2-5=0/2580, 2-6=0/2506, 1-6=0/2753, 3-5=0/2736 NOTES-(10-11) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-3-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1362 lb down at 1-11-4, 1362 lb down at 3-11-4, 1362 lb down at 5-11-4, 1362 lb down at 7-11-4, and 1362 lb down at 9-11-4, and 1368 lb down at 11-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-7=-20 Continued on page 2 February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss TG02 Truss Type COMMON GIRDER Qty 1 Ply 2 12 Copper Run Job Reference (optional) I40137477 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:28 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-hTERpAhrjR9Kl_fjr4pjCHSXvU_qSqRk58UjIBzoZZv LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 6=-1362(F) 8=-1362(F) 9=-1362(F) 10=-1362(F) 11=-1362(F) 12=-1368(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss TG03 Truss Type HALF HIP GIRDER Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137478 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:29 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-9fnq0WiTUkHBN8DvOoKylU?mEuGzBJVuKoEHrdzoZZu Scale = 1:23.1 1 2 3 4 5 9 8 7 61011 2x4 10x16 6x10 2x4 3x8 10x10 4x6 2-9-02-9-0 5-3-82-6-8 7-4-02-0-8 2-9-0 2-9-0 5-3-8 2-6-8 7-4-0 2-0-8 1-9-03-4-51-0-03-6-31-0-04.00 12 Plate Offsets (X,Y)-- [5:0-0-0,0-2-12], [5:0-5-0,Edge], [6:0-0-0,0-2-12], [7:0-8-4,Edge], [7:0-2-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.52 0.55 0.64 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.09 0.00 (loc) 7-8 7-8 6 l/defl >999 >980 n/a L/d 240 180 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-7: 2x6 SPF No.2, 5-6: 2x6 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-5 oc purlins, except end verticals, and 2-0-0 oc purlins (5-2-3 max.): 4-7, 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=968/Mechanical, 9=1811/0-3-8 Max Horz 9=111(LC 26) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1148/0, 4-7=-564/0, 4-5=-1083/0, 1-9=-993/0 BOT CHORD 7-8=0/1836, 6-7=0/1086 WEBS 2-8=0/903, 2-4=-1155/0, 4-8=-789/0, 1-8=0/1163 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 746 lb down at 0-1-12, and 738 lb down at 2-4-12, and 738 lb down at 4-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 4-5=-60, 6-9=-20 Concentrated Loads (lb) Vert: 9=-746(B) 10=-738(B) 11=-738(B)February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V01 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137479 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:31 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-51vaRBjk?MXvcRNIWDMQqv422izTfLwAn6jNvWzoZZs Scale = 1:20.7 1 2 3 2x4 2x4 2x4 5-3-11 5-3-11 0-0-43-6-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.82 0.49 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-11 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=194/5-3-5, 3=194/5-3-5 Max Horz 1=88(LC 7) Max Uplift 3=-25(LC 10) Max Grav 1=194(LC 1), 3=202(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V02 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137480 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:32 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-ZETyfXkMmffmEbyU4wufN7dNu6OiOoAK0mSxSyzoZZr Scale = 1:12.2 1 2 3 2x4 2x4 2x4 2-9-11 2-9-11 0-0-41-10-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-11 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=94/2-9-5, 3=94/2-9-5 Max Horz 1=43(LC 7) Max Uplift 3=-12(LC 10) Max Grav 1=94(LC 1), 3=98(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V03 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137481 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:33 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-2Q1Kstl_XzndrlXhddPuvK9SzVhX7FQTFQCU_PzoZZq Scale: 3/4"=1' 1 2 3 2x4 2x4 2x4 4-6-0 4-6-0 0-0-42-7-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.53 0.32 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=160/4-6-0, 3=160/4-6-0 Max Horz 1=64(LC 7) Max Uplift 3=-18(LC 10) Max Grav 1=160(LC 1), 3=164(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V05 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137482 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:34 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Wcbj3DmcIHvTTv6tBLw7SYiehv1cshKdT4x1WrzoZZp Scale = 1:27.2 1 2 3 4 5 6 3x6 4x6 3x6 2x4 10-6-710-6-7 5-3-3 5-3-3 10-6-7 5-3-3 0-0-44-4-110-0-410.00 12 Plate Offsets (X,Y)-- [2:0-3-13,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.47 0.27 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=195/10-6-7, 3=195/10-6-7, 4=391/10-6-7 Max Horz 1=74(LC 7) Max Uplift 1=-2(LC 10), 3=-9(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Exterior(2R) 3-4-9 to 7-1-13, Exterior(2E) 7-1-13 to 10-1-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V06 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137483 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:35 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-_p95HZmE3a1K53h3l2RM?lFr_JPCb9Lmikhb2HzoZZo Scale = 1:20.9 1 2 3 4 5 6 2x4 3x4 2x4 2x4 0-0-50-0-5 7-3-57-3-1 3-7-11 3-7-11 7-3-5 3-7-11 0-0-43-0-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.18 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=152/7-2-12, 3=152/7-2-12, 4=232/7-2-12 Max Horz 1=50(LC 7) Max Uplift 1=-12(LC 11), 3=-18(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-7 to 3-3-7, Exterior(2R) 3-3-7 to 3-11-14, Exterior(2E) 3-11-14 to 6-11-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V07 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137484 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:36 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-S?iTUvnsqu9BjDGFJmybXzn46jkOKc9wxOQ8bkzoZZn Scale = 1:11.3 1 2 3 2x4 2x4 2x4 0-0-50-0-5 4-0-154-0-10 2-0-8 2-0-8 4-0-15 2-0-8 0-0-41-8-60-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.25 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-15 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=140/4-0-5, 3=140/4-0-5 Max Horz 1=-26(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V09 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137485 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:37 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-wBGriFoUbCH2KMrSsTTq4AKBj74J33S3A2Ai7AzoZZm Scale = 1:26.1 1 2 3 4 5 6 3x6 3x6 3x6 2x4 0-0-50-0-5 9-4-49-3-15 4-8-2 4-8-2 9-4-4 4-8-2 0-0-43-10-120-0-410.00 12 Plate Offsets (X,Y)-- [2:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.36 0.20 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=172/9-3-10, 3=172/9-3-10, 4=344/9-3-10 Max Horz 1=-65(LC 6) Max Uplift 1=-2(LC 10), 3=-8(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Exterior(2R) 3-4-9 to 5-11-10, Exterior(2E) 5-11-10 to 8-11-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V10 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137486 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:38 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-OOqDvbp7MVPvyWPeQB_3cOtN8WRloWFCOivFfczoZZl Scale = 1:18.3 1 2 3 4 2x4 3x4 2x4 2x4 0-0-50-0-5 6-1-136-1-9 3-0-15 3-0-15 6-1-13 3-0-15 0-0-42-6-120-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.25 0.12 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=127/6-1-4, 3=127/6-1-4, 4=193/6-1-4 Max Horz 1=-42(LC 6) Max Uplift 1=-10(LC 11), 3=-15(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V11 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137487 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:38 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-OOqDvbp7MVPvyWPeQB_3cOtQPWR0oWfCOivFfczoZZl Scale = 1:8.9 1 2 3 2x4 2x4 2x4 2-11-22-11-2 2-11-70-0-5 1-5-12 1-5-12 2-11-7 1-5-12 0-0-41-2-120-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-7 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=95/2-10-13, 3=95/2-10-13 Max Horz 1=-18(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V12 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137488 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:39 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-saOc7wpl7pXmag_q_uWI9bPVawl4XxvMdMfoB2zoZZk Scale = 1:35.3 1 2 3 5 4 6 7 3x6 2x4 2x4 2x4 2x4 10-9-4 10-9-4 0-0-46-3-67.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.40 0.25 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=202/10-8-13, 4=80/10-8-13, 5=528/10-8-13 Max Horz 1=161(LC 7) Max Uplift 4=-17(LC 7), 5=-89(LC 10) Max Grav 1=202(LC 18), 4=89(LC 17), 5=529(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-375/140 NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 6-5-1, Exterior(2R) 6-5-1 to 10-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V13 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137489 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:40 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Kmy_KGqNu7fdBqZ1Yc1XipyhiK5nGQHVs0OMkVzoZZj Scale = 1:26.8 1 2 3 5 42x4 2x4 2x4 2x4 2x4 7-10-15 7-10-15 0-0-44-7-67.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.22 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=101/7-10-8, 4=120/7-10-8, 5=371/7-10-8 Max Horz 1=118(LC 7) Max Uplift 4=-10(LC 7), 5=-63(LC 10) Max Grav 1=112(LC 18), 4=127(LC 17), 5=372(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-279/144 NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V14 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137490 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:40 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Kmy_KGqNu7fdBqZ1Yc1XipyhkK4UGQ9Vs0OMkVzoZZj Scale = 1:16.7 1 2 3 4 5 3x4 2x4 3x4 2x4 5-0-115-0-11 4-1-0 4-1-0 5-0-11 0-11-10 0-0-42-4-107.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-0-4], [3:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.37 0.30 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-11 oc purlins, except end verticals, and 2-0-0 oc purlins: 2-3. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=182/5-0-4, 4=182/5-0-4 Max Horz 1=59(LC 7) Max Uplift 1=-1(LC 10), 4=-7(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Exterior(2R) 3-4-13 to 4-1-0, Exterior(2E) 4-1-0 to 4-11-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 12_Copper_Run Truss V15 Truss Type Valley Qty 1 Ply 1 12 Copper Run Job Reference (optional) I40137491 8.240 s Dec 6 2019 MiTek Industries, Inc. Tue Feb 4 09:02:41 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:SGPsrMIORHY7TCHdjVVp3Szroeb-pzWMXcr?fQoUp_8D5JYmE0VwrkUW?tPf4g8vGxzoZZi Scale = 1:7.0 1 2 3 2x4 2x4 2x4 2-7-1 2-7-1 0-0-40-10-64.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-1 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=72/2-6-5, 3=72/2-6-5 Max Horz 1=19(LC 7) Max Uplift 1=-2(LC 6), 3=-5(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). February 4,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths