Loading...
HomeMy WebLinkAboutS000.3{\LOUTSIDE ELEVATION}{\LSECTION A-A THROUGH PIER} {\LINSIDE ELEVATION} \A1;SIMPSON STRAP SPEC BASED ON PONY WALL HEIGHT \P-MSTA49 STRAP w/ 24 {\H0.7x;\S1#2;}" END LENGTH FOR 2'-0" MAX HT.\Por MSTC66 STRAP w/ 33" END LENGTH FOR 5'-0" MAX HT.\P-STRAP CENTERED @ BOTTOM OF HEADER \P- LOCATE ON INSIDE FACE OF WALL. IF PANEL SPLICE IS NEEDED IT SHALL OCCUR WITHIN\PMIDDLE 24" OF WALL HEIGHT. PROVIDE 2x HORIZONTAL BLOCKING TO SUPPORT PANEL EDGES. \A1;FASTEN SHEATHING TO HEADER WITH 2{\H0.7x;\S1#2;}"x0.131"\PNAILS IN 3" GRID PATTERN AS SHOWN AND 3" O.C.\PIN ALL FRAMING (STUDS & SILLS) - TYPICAL. (3" OC. NAILIING ONLY REQ'D WHERE INDICATED BY X's - USE STND. SHTG. NAILING ELSEWHERE) 1/2" DIA. ANCHOR BOLT W/ 7" MIN. EMBEDMENT & 2"x2"x3/16" PLATE WASHER, TYP. SEE TYP. CORNER FRAMING DETAIL \A1;FASTEN TOP PLATE TO HEADER W/ 2 ROWS OF 3{\H0.7x;\S1#4;}"x0.148" NAILS @ 3" O.C. \A1;3"x11 {\H0.7x;\S1#4;}" MIN. HEADER (SEE PLAN) \A1;3{\H0.7x;\S1#4;}"x0.148" NAILS IN (2) ROWS @ 3"O.C. \A1;NOTE: ALL SHEATHABLE AREAS OF EXTERIOR WALL SHALL BE FULLY SHEATHED WITH {\H0.7x;\S1#2;\H1.429x;" PLYWOOD OR \H0.7x;\S7#16;\H1.429x;" OSB} {\LPLAN VIEW OF CORNER DETAIL} \pxqc;PORTAL\PFRAME\PWALL SEGMENT \A1;3{\H0.7x;\S1#4;}"x0.148" NAIL AT \P12" O.C. \A1;ANCHOR BOLTS PER CODE (2 MIN.)\PWITH 2"x2"x{\H0.7x;\S3#16;}" PLATE WASHERS. \A1;10'-0" MAX.\PTO TOP OF HEADER \A1;FINISHED WIDTH < 18'-0"\A1;MIN. PANEL WIDTH BASED ON \P6:1 HEIGHT-TO-WIDTH ASPECT RATIO \PFOR EXAMPLE: 16" MIN. FOR 8' HEIGHT \A1;{\Farchquik.shx;EXTENT OF HEADER} BLOCKING AS REQ'D FOR SHEATH'G SPLICE\A1;10'-0" MAX.\PTO TOP OF HEADER \A1;FINISHED WIDTH < 18'-0" SCALE: N.T.S. GARAGE PORTAL FRAME BRACING ELEVATION SHEATHING FILLER\PAS REQ'D {\Farchquik.shx;A} A \A1;2{\H0.7x;\S1#2;}"x0.131" NAIL @ \P6" O.C. IN ALL\PPANEL EDGES\PNOT PART OF\PPORTAL FRAME KING STUD \A1;{\H0.7x;\S7#16;}" OSB OR {\H0.7x;\S1#2;}" PLYWOOD SHEATHING, CONTINUOUS FROM TOP TO BOTTOM OF WALL, OR FROM TOP OF WALL TO PERMITTED SPLICE AREA. \A1;12' MAX. WALL HEIGHT \A1;FASTEN HEADER TO KING \PSTUDS W/ (6) 3{\H0.7x;\S1#4;}"x0.148" NAILS MIN. (2) JACK STUDS OR AS NOTED ON PLAN \A1;{\Farchquik.shx;EXTENT OF HEADER} \A1;12' MAX. WALL HEIGHT \A1;3"x11 {\H0.7x;\S1#4;\H1.429x;" MIN. HEADER (SEE PLAN)} MIN. (2) JACK STUDS OR AS NOTED ON PLAN \pxql;LOCATE HEADER @ TOP OF OPENING \A1;END LENGTH BOTH SIDES OF GARAGE DOOR {\Farchquik.shx;A} \pxql;LOCATE HEADER @ TOP OF OPENING JACK STUD \A1;ALTERNATIVES TO {\H0.7x;\S1#2;}" DIA. ANCHOR BOLT:\P1) {\H0.7x;\S1#2;}" DIA. x 6" LONG SIMPSON TITEN HD\P2) {\H0.7x;\S1#2;}" DIA. THREADED ROD EPOXY SET w/4 {\H0.7x;\S1#2;}" EMBED. (MIN) UTILIZING HILTI HY200 EPOXY ANCHORING SYSTEM (OR EQUAL) \A1;PONY WALL MAX. HT.:\P=2'-0" w/ SIMPSON MSTA49\P=5'-0" w/ SIMPSON MSTC66 \A1;END LENGTH 115 MPH WIND SPEED (ULT) \A1;PONY WALL MAX. HT.:\P=2'-0" w/ SIMPSON MSTA49\P=5'-0" w/ SIMPSON MSTC66 \A1;SIMPSON STRAP SPEC BASED ON PONY WALL HEIGHT \P-MSTA49 STRAP w/ 24 {\H0.7x;\S1#2;}" END LENGTH FOR 2'-0" MAX HT.\Por MSTC66 STRAP w/ 33" END LENGTH FOR 5'-0" MAX HT.\P-STRAP CENTERED @ BOTTOM OF HEADER \P- LOCATE ON INSIDE FACE OF WALL. \A1;WALL FRAMING SPECIFICATION:\P@2x4 WALL: USE HF #2 GRADE STUDS (OR BETTER)\P@2x6 WALL: USE SPF 'STUD' GRADE STUDS (OR BETTER) (c) Copyright 2019 PulteGroup, Inc.1900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone Office04/19/2017JGF Single Family ---- ALLISON II 2377.300 2.111/29/2017STRUCT REV (MW)...3.103/23/2018STRUCT REV (MW)3.208/22/20182 ELEV ADDED (OH)3.312/07/2018STRUCT REV (MW)4.005/10/2019PCR UPDATE (MW) PRODUCT MANAGERINITIAL RELEASEDATE:REV#DATE/DESCRIPTION PROJECT TYPE SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER 3.012/01/2017PCR UPDATE 4.012/31/2019OH ADDED ELEV. S-4.0...LATERAL DETAILS - IN03/03/20 Adam Schriner