HomeMy WebLinkAboutPermit Plans_Robertson,Kevin_022620UMACINV MSPVICINITY MAP ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS PRN NUMBER: GRN-008006 UTILITY:DUKE ENERGY SHEET CATALOG INDEX NO. DESCRIPTION T-1 COVER PAGE M-1 MOUNTING DETAIL M-2 STRUCTURAL DETAIL E-1 SINGLE LINE DIAGRAM PL-1 WARNING PLACARDS SS SPEC SHEET(S) SITE PLAN LAYOUT (E) MAIN SERVICE PANEL(INTERIOR) (N) PV INVERTER (EXTERIOR) PHOTOVOLTAIC ARRAY ON THE ROOF ·ELECTRIC CODE:IEC 2009 ·FIRE CODE:IFC 2014 ·BUILDING CODE:IBC 2014 ·RESIDENTIAL CODE:IRC 2005 APPLICABLE CODES CHAMBRAY DR KEVIN ROBERTSON - 5.440kW DC, 3.800kW AC COVER PAGE T-1 1.MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3.DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4.WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 5.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6.ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9.ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING GENERAL NOTES SCOPE OF WORK GENERAL SYSTEM INFORMATION: SYSTEM SIZE: 5440W DC, 3800W AC MODULES: (17)HANWHA Q.PEAK DUO BLK-G5 320W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3800H-US (240V) SCALE:1"=30'-0" (N) AC DISCONNECT (EXTERIOR) DRIVE WAY CONDUIT RUN 3' FIRE SETBACK PROPERTY LINE FENCE FENCE 185'-8" 185'-8" 109'-2" 71'-3" 12'-10" 13'-2" 77'-8" (E) UTILITY METER(EXTERIOR) 03/04/20 Nick Mishler AERIAL VIEW ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 MOUNTING DETAIL M-1SCALE:1/8"=1'-0" ARRAY MP-01 SITE INFORMATION - WIND SPEED: 115 MPH AND SNOW LOAD: 20 PSF SR. NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.)ROOF TYPE ATTACHMENT ROOF EXPOSURE FRAME TYPE FRAME SIZE FRAME SPACING MAX RAIL SPAN OVER HANG MP-01 270° 18° 17 308.4 COMPOSITION SHINGLE FLASH FOOT 2 ATTIC PRE FABRICATED TRUSSES 2 X8 2'-0" 4'-0" 2'-0" NOTE: PENETRATIONS ARE STAGGERED ALUMINIUM RAILS 2X8 PRE FABRICATED TRUSSES@ 2'-0"SPACING 4' INSTALLATION NOTES 1.STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTOR WHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. 2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. 3.LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. 4.ALL PV RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. 5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6.ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 1-1/2" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. ROOF ACCESS PATHWAYS AND SETBACKS: IFC 605.11.3.2.1 RESIDENTIAL BUILDINGS WITH HIP ROOF LAYOUTS. PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH HIP ROOF LAYOUTS SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3-FOOT-WIDE (914 MM) CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS/MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE LOCATED AT A STRUCTURALLY STRONG LOCATION ON THE BUILDING CAPABLE OF SUPPORTING THE LIVE LOAD OF FIRE FIGHTERS ACCESSING THE ROOF. IFC 605.11.3.2.2RESIDENTIAL BUILDINGS WITH A SINGLE RIDGE. PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO, 3-FOOT-WIDE (914 MM) ACCESS PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS/MODULES ARE LOCATED. IFC 605.11.3.2.3 RESIDENTIAL BUILDINGS WITH ROOF HIPS AND VALLEYS. PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH ROOF HIPS AND VALLEYS SHALL BE LOCATED NO CLOSER THAN 18 INCHES (457 MM) TO A HIP OR A VALLEY WHERE PANELS/MODULES ARE TO BE PLACED ON BOTH SIDES OF A HIP OR VALLEY. WHERE PANELS ARE TO BE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY THAT IS OF EQUAL LENGTH, THE PANELS SHALL BE PERMITTED TO BE PLACED DIRECTLY ADJACENT TO THE HIP OR VALLEY. IFC 605.11.3.2.4 RESIDENTIAL BUILDING SMOKE VENTILATION. PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS SHALL BE LOCATED NO HIGHER THAN 3 FEET (914 MM) BELOW THE RIDGE IN ORDER TO ALLOW FOR FIRE DEPARTMENT SMOKE VENTILATION OPERATIONS. 03/04/20 Nick Mishler MODULE END CLAMPMID CLAMPMODULE MODULES DATA HANWHA Q.PEAK DUO BLK-G5 320W MODULE DIMS 66.3"x39.4"x1.26" LAG SCREWS 5/16"x3.5":2.5"MIN EMBEDMENT ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 STRUCTURAL DETAIL M-2 MID-CLAMP AND END-CLAMP ANATOMY ATTACHMENT DETAIL-FLASH FOOT 2 FLASH FOOT 2SOLAR MODULE STAINLESS STEEL 5/16" HANGER BOLT 2.5" EMBEDMENT PILOT HOLE REQUIRED RAIL FLASHING 6" MAX SCALE:NTS GROUNDING LUG MID CLAMP ASSEMBLY MODULE FRAME RAIL MODULE TO MODULE & MODULE TO RAIL GROUNDING MID-CLAMP SCALE: NTS GROUNDING DETAILS IRONRIDGE RAIL IRONRIDGE INTERNAL SPLICE SELF-DRILLING SCREW SCALE: NTS RAIL TO RAIL T-BOLT DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 17 41.2 700.40 MID-CLAMP 24 0.050 1.20 END-CLAMP 20 0.050 1.00 RAIL LENGTH 189 0.680 128.52 SPLICE BAR 8 0.630 5.04 FLASH FOOT 2 55 1.88 103.40 TOTAL WEIGHT OF THE SYSTEM (LBS) 939.56 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 308.39 WEIGHT PER SQ. FT.(LBS) 3.05 WEIGHT PER PENETRATION (LBS) 17.08 2 X8 TRUSSES @2'-0"SPACING COMPOSITION SHINGLE ROOF MODULE 5/16" X 3.5" LAG SCREW 1 BOLT PER PENETRATION LOAD BEARING WALL SCALE:NTS ROOF FRAMING DETAILS 03/04/20 Nick Mishler (N)SOLAREDGE TECHNOLOGIES SE3800H-US (240V), 3800W INVERTER INVERTER-1 DC DISCO DC AC LOAD RATED DC DISCONNECT & AFCI (N)JUNCTION BOX OR EQUI. 3 3 2 1 PV MODULES G (N)HANWHA Q.PEAK DUO BLK-G5 320W, 320W MODULES 17 MODULES WIRED IN (1) SERIES OF 17 MODULES SOLAREDGE POWER OPTIMIZERS (N)60A AC DISCONNECT (E)200A END FED MAIN PANEL UTILITY GRID (E)200A MAINBREAKERPV BREAKER AT THE OPPOSITE END OF BUSBAR (E) GROUND ELECTRODE 20A 2P PV BREAKER EXISTING 120/240V 1PH 60HZ METER#:DUKE ENERGY 318 546 523M SIEMENS LN222RA OR EQUIV. PV SYSTEM AC DISCONNECT SWITCH NON FUSED, 60A, 1PH, 120/240V 2P,NEMA 3R SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 5440W, AC SYSTEM SIZE - 3800W ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 SINGLE LINE DIAGRAM E-1 SYSTEM CHARACTERISTICS DC SYSTEM SIZE 5440W INVERTER STRING VOLTAGE:Vmp 380V MAX INVERTER SYSTEM VOLTAGE: Voc 480V MAX SHORT CIRCUIT CURRENT 15A OPERATING CURRENT 14.32A INVERTER-1 SPECIFICATIONS MODEL SOLAREDGE TECHNOLOGIES SE3800H-US (240V) POWER RATING 3800W MAX OUTPUT CURRENT 16A CEC WEIGHTED EFFICIENCY 98% MAX INPUT CURRENT 10.5A MAX DC VOLTAGE 480V MODULE SPECIFICATION MODEL HANWHA Q.PEAK DUO BLK-G5 320W MODULE POWER @ STC 320W OPEN CIRCUIT VOLTAGE:Voc 40.56V MAX POWER VOLTAGE:Vmp 33.8V SHORT CIRCUIT VOLTAGE:Isc 9.94A MAX POWER CURRENT:Imp 9.47A ELECTRICAL CALCULATIONS DC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS>> ·REQUIRED CONDUCTOR AMPACITY: 125% PER 690.8(A)(1) X Isc(A) X #OF PARALLEL STRINGS = MAX CURRENT PER 690.8(A)(1) X 125% PER 690.8(B)(2)(a)=MAX CURRENT PER 690.8(B)(2)(a) · CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATE FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY ·DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> ·REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF INVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A) · CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATE FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY ·DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY OPTIMIZER CHARACTERISTICS MODEL P340 MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 48 VDC MAX INPUT CURRENT 11 ADC MAX OUTPUT CURRENT 15 ADC NOTES: 1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 310.0(D). 2.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.8(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS TO NEC 240.6 CODE SECTION. 6.AC GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC 250.66. 7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON NEC 690.31(C). 8.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON NEC 310.15(B)(2)(C). 9.MAX. SYSTEM VOLTAGE CORRECTION IS PER NEC 690.7. 10.CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE NEC 310.16. NOTE: MAIN PANEL RATING:200A, MAIN BREAKER RATING:200A 120% RULE: (200AX1.2)-200A=40A =>ALLOWABLE BACKFEED IS 40A OCPD CALCULATIONS: INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25) =16x1.25=20.00A=>PV BREAKER = 20A ALLOWABLE BACKFEED 40A =>20A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(D)(2) REQUIREMENTS. CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10AWG PV WIRE NONE (1) 10AWG BARE COPPER 2 3/4"IMC (4) 10AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 3 3/4"IMC (2) 10AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 WIRE SIZE DETERMINED PER INVERTER DC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK 1 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.58 X 1 = 23.20A 18.75A < 23.20A 2 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.71 X 0.8 = 22.72A 18.75A < 22.72A AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK 3 16 X 1 = 16 X 1.25 = 20.00A 40 X 0.87 X 1 = 34.80A 20.00A < 34.80A 03/04/20 Nick Mishler UMACINV MSPWARNING PLACARD ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 WARNING PLACARDS PL-1 ! ! ! ! ! A V 15 480 380RATED MAXIMUM POWER- POINT VOLTAGE(Vmp) MAXIMUM SYSTEM VOLTAGE(Voc) MAXIMUM CIRCUIT CURRENT(Isc) RATED MAXIMUM POWER- POINT CURRENT(Imp) INVERTER 1 WARNING CAUTION: SOLAR CIRCUIT CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7) [ Not Required if Panel board is rated not less than sum of ampere ratings of all overcurrent devices supplying it] ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION DC DISCONNECT,INVERTER [PER CODE: NEC 690.35(F)] [To be used when inverter is ungrounded] WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION CONDUIT, COMBINER BOX [PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4)] WARNING-Electric Shock Hazard No User Serviceable Parts inside Contact authorized service provide for assistance LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT [PER CODE: NEC 690.13.G.3 & NEC 690.13.G.4] LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION [PER CODE: NEC690.13(B)] LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION [PER CODE: NEC 690.54] LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. (PER CODE: IFC605.11.1.4) LABEL LOCATION POINT OF INTERCONNECTION [PER CODE: NEC705.12(D)(4)] ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: NEC 690.17(E)] DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: NEC 690.17(E)] LABEL LOCATION WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. (PWER CODE: NEC690.15 ,690.13(B)) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SOLAR DISCONNECT V A 14.32 WARNING LABEL LOCATION DC DISCONNECT[PER CODE: NEC690.14(C)(2)] RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 16.00 240 AMPS AC VAC PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN !WARNING: SOLAR PHOTOVOLTAIC ARRAYS ON ROOF ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. FASTENERS APPROVED BY THE LOCAL JURISDICTION (E) UTILITY (EXTERIOR) (N) PV INVERTER (EXTERIOR) (N) AC DISCONNECT(EXTERIOR) (E) MAIN SERVICE PANEL (INTERIOR) 03/04/20 Nick Mishler SPEC SHEET ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 MODULE SPEC SHEET SS-1 03/04/20 Nick Mishler SPEC SHEET ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 INVERTER SPEC SHEET SS-2 03/04/20 Nick Mishler SPEC SHEET ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 OPTIMIZER SPEC SHEET SS-3 03/04/20 Nick Mishler SPEC SHEET ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 MOUNT SPEC SHEET SS-4 03/04/20 Nick Mishler SPEC SHEET ADDRESS:9860 CHAMBRAY DR, INDIANAPOLIS, IN 46280 39°55'54.7"N 86°07'13.2"W APN:291-407-303-027-000-018 DESIGNER/CHECKED BY: CUSTOMER INFORMATION SS/BH NAME: KEVIN ROBERTSON DATE:2/26/20 SCALE:AS NOTED REV:A AHJ:IN- CITY OF INDIANAPOLIS UTILITY:DUKE ENERGY PRN NUMBER: GRN-008006 RAIL SPEC SHEET SS-5 03/04/20 Nick Mishler