Loading...
HomeMy WebLinkAboutA02.3SH6 - Specifications page 3E%TERIOR ONLRMETAL �OORS JAMBS 8 FRAMES iW0 FINISH COATS OVER A PRIMER. • SHERWININILLIAM1IS'. • ��SHEFWIN-WILLNMS�TMACRYLICPRIMEWFlNISH,BBBW1 ' Si & 2ND COATS�. SHERWIN�WILLIAMS PROCLASSIC WATERBORNE INTERIOR ACRVLIC SEMFGL035 ENAMEL, B31W61 SERIES • WLOR'.SWll23-COLONVBUFF OR BENJAMIN MOORE'. PRIMER-A'. MW MET/LL PRIMER I15E� FOR BARE MET/LL AN� SPOT PRIMING. APPLY AT SPREADING RATE TO ACHIEVE A TOTAL DRV FlLM TMCKNESS OF NOT LESS THAN 12 MILS (OA31MMj. BENJAMIN MOORE ACRVLIC METAL PRIMER, MW iST 8 2N� COATS'. M29 �TM SEMI GLOSS ACRYLIC-LATEX ENAMEL APPLIE� AT SPREADING RATE TO ACHI WE A TOTAL DRV FlLM THICKNESS OF NOT LESS THAN 2b MILS �OD66MM1. BENJAMIN MOORE DTM ACRYLIC SEMI�GLOSS ENAMEL M29 WLOR'.HC39PI1TNAMIVORV 11.ELECiRICAL a. ELECTRICALi01NCLU�EOUTLEiSASSHOWNONPAGE5283.INCLU�INGDEDICATED OIITLET AS SHOWN ON PLAN. 1. GENERALPURPOSEOUTLETS • ALLOUTLEiSTOBEPLACEDASSHOWNONDRAWMG. • ONE(1�pl1A�IXITLETATFONREWORKSTATIONLOWTIONAN�j2�p11A�0UTLETS AT BOA WORHSTATION. • ATALLTERMINALSAN�OTHEROFFlCEE�UIPMENTASSHOWNONTHEPLAN. 2 �EDICATE�OUIlET • �EFINITION:A�E�ICATE�OUTLETISWIRE��IRECTLYTOTHEMAINPOWER DISTWBUTION PANEL THROUGHA OESIGNATEO ;�EJICATE�� CIRCUIT BREAKER. THE OE]ICATE� OJT�ETSARE COLOR CO�ED -0 DISTINGl11SH THEM FROM GE\ERA_ PORPOSE OULETS.ONLY THE BOC SHOUL� BE PWGGE� INTO THE oeoicnTeo o�T�eT. Tne TecnNicu mFoemnTioN FORmis ouneT is ns Fouows. • ONE�E�ICATE�OUTLET161MPLE%.NOT�UPLEXIREQl114E�FORNEB00(AEE LEGEN� ON SHEET 1 OF 6). • OUiLETTOBESTANDARD&PRONG,120VOLi.20AMP.DE�ICATE�CIRWIT. • OOTLETTOBESIMPLEX.ORANGEWLORCO�E�RECEPTACLE�NEMATVPESI5 WIG OURET. GE5362-IG OR EQUIV/LLENT�. • ALLGROUN�SMUSTHAVESAMEGROUNDPOTENTIAL. 3. RECESSE�OUTLET • LEVITONRECESSE�ONE-GANG�l1PLEXRECEPTACLE(i5A-025VAC2-POLE,3-WIRE- NEMA S15R�-CAT N0. fie9 TO INCLU�E ELECTRICAL BOX. • cnTn�ocNa.mi�oosae�aaw,uPCNo.o�ean3iiaai • IFABOVESPEQFICATIONISl1NAVAINBLE,FIN�COMPARABLEALTERNATIVE b. ALLOUTLETST08E1IDVOLTSTAN�ARJ3PRONGOUTLEfSTHATMEETSTATEAN�LOCAL RE�UIREMENiS (NEMA TYPE 6�16R} THE GROUN�ING CON�UCTORS FOR iHE BUIL�ING'S CIRCUITS SHOUL� BE REFERENCE� TO THE POINT OF "ZERO CURRENT' WITHIN THE ELECTRICAL SUPPLV SYSTEM. WHICH IS WHERE THE NEUTRAL AN� GROIIN� FOR THE SVSiEM ARE TIED TOGETHER. n E%ISTINGOIITLETSCANBEl15E�TOMEETTHERE0l11REMENTSFORGENERAbPURPOSE OUTLETS ONLY. VERIFV EXISTING OIITLETS TO REMAIN ARE IN WORHING OR�ER. tl. NEWELECTRICALOUTLETSTOBEWSTALLE�WHERESHOWNONPLANSATIO"AFF. UNLESS AN EXISTING �EVICE IS ALREA�Y WITHIN 35" OF THE �E92E� LOCATION. e. �EMOIREMOVEOUTLETSABOVEIB"A.FF.IINLESSNOTE�OTHERWI5E0NPLANS. '. INSTALL OR REPUCE ALL OUTLEf COVERS WITH WHITE FACEPLATES OR TO MATCH EMISTING. CONFlRM W LOR WITH �ESIGNER IF OiHER iHAN WHIiE. g. ALLCOMPUTEREQUIPMENTFORTHISOFFICEISSENSITIVETOHIGHELECTROMAGNETIC RELEA5E0 FOR CONSTRACTION 'N�°RS Subjecttocompliancewithallregulations � of State and Local Codes ARV City of Carniel "y �a<� ��.i..�� o�v��� � oarE: 03/05/20 nMoonTE j. CONTRACi0Ri01N5TALL2'%2'MINIMUMBACKERBOARDOFFRiPLVW00�ATBOC LOCATION. BOAR�TOBEPAINIE�TOMATCHTHEWALLWHENTHEWALLISSCHE�ULE� FOR PAINT PER THE FlNISH SCHEDULE CONFlRM WITH FlRE MARSHALL PRIOR TO PAINTINGAN�LEAVERATINGSTAMPE%POSE�WHENEVERRE4UIRED. BOARDi08E INSTALLE� AT 24' A F F. TO THE BOTTOM AT THE LOWTION SHOWN ON THE PLAN. REFER TO SHEET fi OF fi FOR EXACT LOCATION. k. ELECTRICIANTOINSTALLJIA"CONDUITBBOXWITHPULLSiRMGORMUDRING(EXISiING WALL� AT ALL LOCATIONS �SEE SECTION 4 BELOIM1� WITH LOW VOLTAGE COMMUNICATION CONNECTIONS. INSTALL (1J SINGLE GANG BOHAT EACH LOGATION IN�ICATE� ON THE �RAWINGWITHATRIANGLE���. �O�OTINSTALLADOUBLEGANGBOXATLOCATIONS WHERE (2) SVMBOLS ARE A�JACENT. REFER TO LEGEN� AN� PLANS ON SHEETS id FOR LOCATIONS OF �OIIBLE GANG BOXES. IF CON�UIT IS NOT GOING TO BE INSTALLE�, PLEASE CONTACT �ESIGNER IMMEDIATELY. I. ELECTRICIANTOINSTALLONE7IA"CON�UITFROMBUIL�INGMAINPOINTOFENTRV�MPOE) INTO 80TH SINGLE GANG ELECTRI WL BOXES FOR WCOMING PHONE JACKS IRJi¶ WITHIN 1'-0" OF BOC PER �ETAIL ON PAGE fi OF fi. INC WILL WSTALL THE �UANTITV OF CATS PHONE LMES IN�ICATED ON SHEET 20F 6' CONTRACTOR TO COORDINATE WITH INC. QNTEGRATE� NETWORK CABLE. CONTACT INC INSTALL TEAM AT 888�519�9525�. 4. LOWVOLiAGElAL50KNOWNASPXONFlOATACABLINGI CONDUIi-0EMISED PREMISES a. CON�UIiSiUB-0PSTOBEINSTALLEDINNEWWALLSWHERE PHONEI�ATAipRINTERS ARE SHOWN ON THE FLOOR PLAN (IN�ICATE� BV TRIANGLE� I IF THE NEW CEILING IS DRVWALL, INSTALL CONDUIT FROM THE POINT OF CONNECTION �PHONES/�AiNPRINTER LOCAilON51NDICATE� WITH � � AN� STUB ABOVE CEILING WITH PIILL STRING RUN TO THE POINT OF TERMINATION (CJENT SERVER OR BOC�- b. CONFlRMACTJAL OCATIONSONFLOORPLHNSHEET20F6PRIORTO INSiALNTION. EXISTING CONSTRUCTION��WN�UIT NOT TO BE �ONE IF IT Reo�iRes eevovn� oF oRvwAa anennoNs oe ceamcs. uN�ess aeioe APPROVAL RECENE� FROM E�J �ESIGNER. IF WIREMOLD PRODUCi IS RE�UIRED, INSiALL PAN�UR RACEWAY N10H6�A. c. PROVI�EONESINGLEGANGBOX(ONEPERTRIANGLE�AN�PULLSTRINGAT EACHCONDLIiLOCATION. LHBELPULLSTRINGSATPOINiOFTERMINATION�BOC1 WITH ROOM NUMBER OF POINi OF CONNECTION. tl. IF WALLS ARE EXISTING AN� CON�NT IS NOT INSTALLE�, PROVIDE PULL STRING AND CUT IN A NEW BOX AT THE SAME LOCATIONS. e. SiANDAR�STUB-0P�VANTIiV�.TEN�10)3/4'DIAMETERLOCATIONS,UNLESS NOTE� OTHERWISE ON PLANS- IN�ICATE� BY TRIANGLE SYMBOL ON FLOOR PlANS. a. 3/4'WNDUITLOCATIONS • (2�ATBOA(ROOM101) • (1�ATFAOFFICE�ROOM102) • (4�ATBOCINTO�OUBLEGANGBOXES • (P�ATWCAMINGPHONEIDATALWESTOBOCPERPLAN�ONEACTIVEPoR PHON�S AN� ONE WI p6 GROUN� WIRE RUN FROM BO%TO ELECTRICAL PANEL TO GROON� BOX FOR �ATA� • (1�ATOPEN108 I. ALLBO%ESANDCON�UITAiBOCLOCATIONTOBEINSTALLEDPERDETAIL BELOW. q6 GROUN� WIRE MUST BE INSTALLE� AN� TERMINATE� ON A BOSBAR FOR pfi WIRE MOUNTE� ON THE BOTTOM CORNER OF THE BACK BOAR�. THE BUSBAR SHOULDHAVE4i06iERMINALS W N�UIT AN� PHONE LINES FROM BUIL�ING SOURCE TO FXTEN�E� �EMARC �BOC) a. GENERALWMRACTORTOINSTALL�213i4"CON�UITFROMTHEBl11L�ING SOURCE i0 THE E%iENDE� DEMARC LOCATION WITHIN THE BRANCH (BOC LOCATION SHOWN ON PLANj AS WELL AS COOR�INATE WITH INC TO INSTALL CAiSE PLENUM RATE� PHONE LINES IN OVANTIiV SPECIFIE� ON PAGE 2 WC CONTACT WFORMATION ISAVAILABLE ON SHEET 10F 8. ""IF �ATA LINES ENTER BUIL�ING AT A �IFFEREM LOCATION THAN PHONE LINES (1) CON�WT WILL NEE� TO COME FROM THE �ATA SOURCE TO THE GROUN�E� BOX AT THE BOC LOCATION. REMAINING CONDUIT SHOUL� BE RUN INFROMTHEPHONELWESOURCETOTHEBOC LOCATION""' b. CONTACTBRANCHFACILITIESIMMEDIAiELVIFTHEREAREANVpUE5TI0N5 RE6ARDING THE kV418ER OF PHONES LWES OR LOCATION OF DEMARC E%TENSION CONDUIT. BOCREpl11REMENTS: NOTE: CON�l11T IS INSTALLE� INSI�E WALL IF WALL IS E%ISTING, CON�UIi MAY BE SURFACE MOUME�. MUST HAVE ROOM FOR EQUIPMENT TO WSTALL ON PLYW00�. �SEE KEYED NOTE #1 ON PAGE 20F e PoR CLAPoFlCATION.) 314"GON�UITTOLEG Y4"CON�UITTOAIL �MARCBOX I I I I WORHSTATIONLOCATIONS SINGLEGANGPHONE 2'0"%PO'FRTPLVWOO�.PAINTE� BOXWITHPULLSTRING TOMATCHWALLWILABEL ANDk6GR0UNDWIRE EXPOSED.INSTALLAT36"AFF. BYGC�1NCTORUN�1) TOBOTTOM',BOAR�SUPPLIE�& CATSELMETOTHIS INSTALLE�BVGC. LOCATION� OEDICATED SINPLEX OLTLET i0 ACTIVESMGLEGANG BEMARKEOWI-H"�"80RANGE PHONE BO%WITH PULL IN�ICATE �E�ICATE� BV GC. STRINGSBYGCJNCTO I pOUBLEGANGPHONEBO%ES.GC RUNREMnmwc�a� II II toRUNauusramcTnRoucn CAi5ELWL5�COTi�HN Iy STU� yl EACHCONDUITRUN.WCTORUN � REMAININGCABLESiOVARI0U5 WORHSTATIONLOCATIONS-SEE LOW VOLTAGE WIRING SPECS. LOW VOLTAGE WIRING (ALSO KNOWN AS PHONEIDATA CABLING) a. LOWVOLTAGEIMPLIESiHEACTUALWIREORCABLETHATISRUNFROMTHEBOC TO EACH PHONE, COMPUIER, PRIMER, AND FUTURE WORKSTATION LOCATION. WITH iHE E%CEPTION OF THE �EMARC FXTENSION (BOCJ REFERENCE� IN SECTION 5, LOW VOLTAGE WORK IS �ONE BV E�WAR� JONES BRANCH WSTALL DEPT. THROUGH A PREFERRE� NATIONAL VENOOR. C91Z. TMS WORK IS �ONE AFTER iHE SPACE IS iURNED OVER TO E�N'AR� JONES. b. IF LOW VOLTAGE WORK IS REpUIRE� TO BE PERMITTE� AN� INSPECTE� AS NOTE� ON EXHI9ITA PRIOR TO CLOSING ANV NEW PARTIi10\5. GENERAL coNrancToa is To cooaownTe TNe msrn��nnoN �.virn Eo��vnRo doNes PREFERRE� NATIONAL VEN�OR INC. INC CONTACT IMORMATION IS AVAIIABLE ON SHEET 10F 6. NOTE THAT PRE WIRE IS NOT STANDARO AN� IS ONLY �ONE WHEN RE�UIRED VS. BEING �ONE PoR CONVEWENCE THERE IS A WIRING SPEQFICATION AVAILABLE FOR PROJECTS REpUIRING PREWIRE. u NOiIFVBRANCHFAQLITIESOFLOWVOLTAGEREQUIREMENTSNEE�E�INORDER TO OBTAIN CERTIFlCATE OF OCCUPANCY. 1. ELECTRICALBORES�G%2118�HAN�YBORMUSTBEUSE�,PER�IAGRAM BELOW FOR ALL LOW VOLTAGE APPLICATIONS IN NEW WALLS AN� CONCRETE WALLS. 2. MUDRINGS�MPLSMEiALSINGLEGANGDRYWALLMOUNiINGPLATE,PER �IAGRAM BELOW FOR ALL LOW VOLTAGE APPLICATIONS W EXISTING WALLS. 11.MISLELLANEOUS a FlXEDWINDOW�ONLYIFSHOWNONPAGESI&3) 1. NEWIMERIORWIN�OWBETWEENFAOFFICEAN�BOAARFAiOBEAFIXE�. 41W X 3�"H AN� INSTALLE� AT 41' A.F.F.. UNLE55 NOTE� OTHERWISE', FRAME TO BE WOOD �OR TO MATCH DOOR FRAMES�. 2 PAINiW00�TRIMWHITETOMATCH000WFRAMECOLOR. 3. GLASSTOBEQEAR,Y.'TEMPERE�STATIONARYPANEL.GLI�ERSAN� MIRRORED WINDOWS NOT ALLOWED. b. FIREPLACES,SiOVES.SHOWERS,TUBS 1. ALLGASAN�PLUMBINGLWESTOTHESEELEMENTSIFIXTURESTOBE RENDERED INOPERABLE AN� ALL LWES TO 9E CAPPED. N; -�'.,,��.. . ..";.":`:�'7--. � ► * � n � �a oz a �+zw —> a�o _�� >aw i�z Fo� �Vj�N o�¢? �4�0� 0 roW� �w� . v�n¢ y N � 0 0 wF�o a �caie d � f _ 0 - m 1 ry � — — C c� = o 3 ? U � _ � ¢ �iY:ll:11/:\