HomeMy WebLinkAbout18-840.02 E201 FLOOR PLAN - LIGHTINGRELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel , �{�n„� i�.vavua! �FLOOR PLAN - LIGHTING SCALE: 1I8"=1'-0" o� s� i s� nw o�cmiox OREFER TO LICHiINC CONiROL MAiRI% SCHEOULE ON SHEET E100 FOR MORE MFOANAiION ON SPACE SPECIFlC LIGHiING CONiROLS. � � � � � � KEYED NOTES: OO (E) E%ISiING TO REMAIN. MAINTAIN CIRCUIT INTEGRITY. O ALL E%IT AND EMERGENCY LIGHT FI%TURES SHALL BE CONNECTED TO ROOM LIGHT CIRCUIT AHEAD OF LOCAL CONTROLS. O PROVIDE NEW LIGHTING, LIGHTING CONTROLS AND CONNECT TO E%ISTING BRANCH CIRCUIT SERVMG THE AREA. Oa PROVIUE NEW LIGHTING AND CONNECT TO EXISTING BRANCH CIRWIT AND LIGHTING CONiROLS/CONTACTOR AND TIME SWITCH. LIGHTING NOTES: 1. COORDINATE LIGHTING LAYOUT WITH ARCHITECTURAL REFLECTE� CEILMG PL1N5, AIECHANICAL FLOOR PL4NS AND NECHANICAL DUCT WORK PRIOR TO ROUGH-IN. 2. ELECTRICAL TRADES CONTRACTOR SHALL PROVIDE ALL JUNCTION BO%E5, C-CHANNELS AND SUPPORTMG METHOD FOR SURFACE MOUNTED, PENDANT AND RECESSED LIGHT FIXTURES. 3. ALL L4Y-IN FI%TURE SHALL BE FURNISHED WITH SAFETY CLIPS AND MECHANICALLY ATTACHED TO CEILING GRID SYSTEM, SUPPORTED INDEPENDENTLY FROM BUILDING STEEL. 4. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL lAMPS FOR ALL TYPES OF LIGHTING FI%TURES. 5. ELECTRICAL CONTRACTOR SHALL PROVIDE POWER PACKS AND VERIFY WIRMG FOR THE CEILING MOUNTED MOTION SENSOR WITH THE MANUFACTURER'S REQUIREAIENTS. INSTALL AIOiION SENSOR POWER PACKS ABOVE ACCESSIBLE CEIUNGS. 6. ALL SURFACE MOUNTED LIGHT iRACK SHALL BE FURNISHED COMPLETE WITH ALL AIOUNTING HARDWARE, CONNECTIONS AND ACCESSORIES. 7. THI$ CONiRACTOR SHALL MAKE ALL NECESSARY FIELD CUT$ A$ REQUIRED FOR LENGTH$ OF TRACK AS SHOWN ON THE PLANS AND FURNISH AND INSTALL T-BAR MOUNTING CLIPS AND SHALL PAINT ALL TRACK, iRACK LIGHiINC FIXTURES AND COMPONENTS TO MAiCH CEILING AS REQUIRED. 8. THIS CONiRACTOR SHALL FURNISH LABOR, AT THE DIRECTION OF THE STORE AIANAGER, TO AIM ALL ADJUSTABLE FI%TURE$ AFTER THE $TORE I$ MERCHANDISED. ALLOWANCE $HOULD 6E MADE FOR AIMING TO BE GONE THE MORNING OF OR THE EVENINC PRIOR TO iHE STORE OPENING. 9. INSiALLATION OF LIGHTINQ EQUIPMENT AN� BRANCH CIRCUIT WIRINC, ETC. IN SERVICE WRITE-UP $HALL BE IN ACCOR�ANCE WITH ARTICLE 511 OF iHE LATESi N.E.C. ALONG WITH SEAL-OFF FITTINGS FOR ALL CONDUITS THAT TERMINATE IN OR PASS A THROUGH THE IB" BARRIER ABOVE FINISH FLOOR PER ARTICLE 511 OF THE N.E.C. FOR COMMERCIAL GARAGES, REPAIR AND STORAGE. 10. CIRWIT NUMBERS INDICATED, SHOW INTENT ONLY. ELECTRICAL TRADES CONTRACTOR SHALL FIELD VERIFY EXISTING PANEL CONDITIONS AND CIRCUIT ACCORDINGLY. UTILRE SPARE BREAKERS WHEREVER POSSIBLE TO FEED NEW LIGHTING OR PROVIDE NEW 277 VOLT 20A-1P qRCUIT BREAKER IN EXISTING PANEL SERVING THE AREA, (MAXIMUM OF 3600 WATfS PER BRANCH CIRCUIT). COVERING M/E/P DESIGN ' ���QO �T �R �O�c� No. ' � 10000214 ; Jp STATE OF ' • Q' '����,��, ,`SS/OON6LENG\��F. ivivis ary nm mm a� `mn m� �a �= `o a � �o a'� , �, ' o v ON na TDGArchitects.com � Automotive O � N � N � LL Z a C)W�' 0 � � � � W 0 U W� O Z��; >oM � W � ��� L O Oi a� � Q� N � = C�O O � � d � � � � _ Q W m W � � � � J W�, � Cn � � O W � � Z � O d= � v U a N m Rsvleian Scheduls Date DeecrlpHon 03-13-19 Review 10-03-19 Bids 11-11-19 Permits EAM Engineers, Inc. EleclricelaiM MechenialGonsNGng Englneare 400 S. OI4 Wootlma�d SUVs 1 W, Bimiingham, MI 480�B PM1one248S4A16]0 Faz24&528.1642 mw✓.eem�eqqlnaersnom � eam(A}am�eqqlneer.vcvm ]ab Na.: 423—IB041 � . , � � . 1- .- e � e Z 8� Q Sv J g` � Z �� r O r a: H O � � s' � (� � � o L.L J � $ Proiect Number 18-840.02 Drawing Number E 201 DATE: 03�Q�j�20